aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-class-hwmon
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-hwmon')
-rw-r--r--Documentation/ABI/testing/sysfs-class-hwmon110
1 files changed, 100 insertions, 10 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon
index 638f4c6d4ec7..3dac923c9b0e 100644
--- a/Documentation/ABI/testing/sysfs-class-hwmon
+++ b/Documentation/ABI/testing/sysfs-class-hwmon
@@ -381,6 +381,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_max_alarm
+Description:
+ Maximum temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_max
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_min
Description:
Temperature min value.
@@ -389,6 +398,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_min_alarm
+Description:
+ Minimum temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_min
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_max_hyst
Description:
Temperature hysteresis value for max limit.
@@ -434,12 +452,7 @@ Description:
- 0: OK
- 1: temperature has reached tempY_crit
- RW
-
- Contrary to regular alarm flags which clear themselves
- automatically when read, this one sticks until cleared by
- the user. This is done by writing 0 to the file. Writing
- other values is unsupported.
+ RO
What: /sys/class/hwmon/hwmonX/tempY_crit_hyst
Description:
@@ -462,6 +475,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/tempY_emergency_alarm
+Description:
+ Emergency high temperature alarm flag.
+
+ - 0: OK
+ - 1: temperature has reached tempY_emergency
+
+ RO
+
What: /sys/class/hwmon/hwmonX/tempY_emergency_hyst
Description:
Temperature hysteresis value for emergency limit.
@@ -887,15 +909,15 @@ Description:
RW
-What: /sys/class/hwmon/hwmonX/humidityY_input
+What: /sys/class/hwmon/hwmonX/humidityY_alarm
Description:
- Humidity
+ Humidity limit detection
- Unit: milli-percent (per cent mille, pcm)
+ - 0: OK
+ - 1: Humidity limit has been reached
RO
-
What: /sys/class/hwmon/hwmonX/humidityY_enable
Description:
Enable or disable the sensors
@@ -908,6 +930,74 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/humidityY_fault
+Description:
+ Reports a humidity sensor failure.
+
+ - 1: Failed
+ - 0: Ok
+
+ RO
+
+What: /sys/class/hwmon/hwmonX/humidityY_input
+Description:
+ Humidity
+
+ Unit: milli-percent (per cent mille, pcm)
+
+ RO
+
+What: /sys/class/hwmon/hwmonX/humidityY_label
+Description:
+ Suggested humidity channel label.
+
+ Text string
+
+ Should only be created if the driver has hints about what
+ this humidity channel is being used for, and user-space
+ doesn't. In all other cases, the label is provided by
+ user-space.
+
+ RO
+
+What: /sys/class/hwmon/hwmonX/humidityY_max
+Description:
+ Humidity max value.
+
+ Unit: milli-percent (per cent mille, pcm)
+
+ RW
+
+What: /sys/class/hwmon/hwmonX/humidityY_max_hyst
+Description:
+ Humidity hysteresis value for max limit.
+
+ Unit: milli-percent (per cent mille, pcm)
+
+ Must be reported as an absolute humidity, NOT a delta
+ from the max value.
+
+ RW
+
+What: /sys/class/hwmon/hwmonX/humidityY_min
+Description:
+ Humidity min value.
+
+ Unit: milli-percent (per cent mille, pcm)
+
+ RW
+
+What: /sys/class/hwmon/hwmonX/humidityY_min_hyst
+Description:
+ Humidity hysteresis value for min limit.
+
+ Unit: milli-percent (per cent mille, pcm)
+
+ Must be reported as an absolute humidity, NOT a delta
+ from the min value.
+
+ RW
+
What: /sys/class/hwmon/hwmonX/humidityY_rated_min
Description: