aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/mellanox/mlx5/core/eswitch.c
AgeCommit message (Collapse)Author
2016-08-17net/mlx5: Unify and improve command interfaceSaeed Mahameed
Now as all commands use mlx5 ifc interface, instead of doing two calls for executing a command we embed command status checking into mlx5_cmd_exec to simplify the interface. Also we do here some cleanup for redundant software structures (inbox/outbox) and functions and improved command failure output. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Leon Romanovsky <leon@kernel.org>
2016-07-05net/mlx5: Refactor mlx5_add_flow_ruleMaor Gottlieb
Reduce the set of arguments passed to mlx5_add_flow_rule by introducing flow_spec structure. Signed-off-by: Maor Gottlieb <maorg@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-07-02net/mlx5: Add Representors registration APIHadar Hen Zion
Introduce E-Switch registration/unregister representors functions. Those functions are called by the mlx5e driver when the PF NIC is created upon pci probe action regardless of the E-Switch mode (NONE, LEGACY or OFFLOADS). Adding basic E-Switch database that will hold the vport represntors upon creation. This patch doesn't add any new functionality. Signed-off-by: Hadar Hen Zion <hadarh@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-07-02net/mlx5e: Add devlink based SRIOV mode changesOr Gerlitz
Implement handlers for the devlink commands to get and set the SRIOV E-Switch mode. When turning to the switchdev/offloads mode, we disable the e-switch and enable it again in the new mode, create the NIC offloads table and create VF reps. When turning to legacy mode, we remove the VF reps and the offloads table, and re-initiate the e-switch in it's legacy mode. The actual creation/removal of the VF reps is done in downstream patches. Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-07-02net/mlx5: E-Switch, Add support for the sriov offloads modeOr Gerlitz
Unlike the legacy mode, here, forwarding rules are not learned by the driver per events on macs set by VFs/VMs into their vports, but rather should be programmed by higher-level SW entities. Saying that, still, in the offloads mode (SRIOV_OFFLOADS), two flow groups are created by the driver for management (slow path) purposes: The first group will be used for sending packets over e-switch vports from the host OS where the e-switch management code runs, to be received by VFs. The second group will be used by a miss rule which forwards packets toward the e-switch manager. Further logic will trap these packets such that the receiving net-device as seen by the networking stack is the representor of the vport that sent the packet over the e-switch data-path. Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-07-02net/mlx5: E-Switch, Add operational mode to the SRIOV e-SwitchOr Gerlitz
Define three modes for the SRIOV e-switch operation, none (SRIOV_NONE, none of the VF vports are enabled), legacy (SRIOV_LEGACY, the current mode) and sriov offloads (SRIOV_OFFLOADS). Currently, when in SRIOV, only the legacy mode is supported, where steering rules are of the form: destination mac --> VF vport This patch does not change any functionality. Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-06-09net/mlx5: E-Switch, always set mc_promisc for allmulti vportsMohamad Haj Yahia
Set the mc_promisc flag also in the case of adding new mc address to existing allmulti vport. Fixes: a35f71f27a61 ('net/mlx5: E-Switch, Implement promiscuous rx modes vf request handling') Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-06-09net/mlx5: E-Switch, Modify node guid on vf set MACNoa Osherovich
In RoCE, the RDMA-CM needs the node guid to establish connection between nodes. Today, the node guid exposed to mlx5 Ethernet VFs is zero, therefore RDMA-CM on the VF is broken. Whenever the administrator sets a MAC for a VF, derive the node guid from it and set it as well in the following way: MAC: e4:1d:2d:b3:f4:01 -> node_guid: e4:1d:2d:ff:fe:b3:f4:01 Fixes: 77256579c6b43 ('net/mlx5: E-Switch, Introduce Vport...') Signed-off-by: Noa Osherovich <noaos@mellanox.com> Signed-off-by: Majd Dibbiny <majd@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-06-09net/mlx5: E-Switch, Fix vport enable flowMohamad Haj Yahia
Reorder vport enable flow to mark the vport as enabled before calling the vport change handler which was modified to handle the case for when vport is not enabled. This fixes the case for when the PF netdev is open before sriov is enabled, once sriov is enabled at esw_enable_vport, esw_vport_change_handle_locked didn't read the PF context since it thought the PF vport was not enabled. When we enable the vport, arming for events is not required anymore, since it's done on the vport change handle Fixes: 586cfa7f1d58 ('net/mlx5: E-Switch, Use vport event handler for vport cleanup') Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-06-09net/mlx5: E-Switch, Use the correct error check on returned pointersOr Gerlitz
The mlx5 flow-steering API (mlx5_create_flow_table/group/rule) never returns null pointer on error. Even if it was doing that, checking for IS_ERR_OR_NULL(p) and then returning PTR_ERR(p) would have cause bugs, since PTR_ERR(NULL) --> success, crash. To make things more robust and protect against related future bugs, convert all IS_ERR_OR_NULL checks on returned values to IS_ERR. Fixes: 5742df0f7dbe ('net/mlx5: E-Switch, Introduce VST vport ingress/egress ACLs') Fixes: 86d722ad2c3b ('net/mlx5: Use flow steering infrastructure for mlx5_en') Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Reported-by: Ilya Lesokhin <ilyal@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-06-09net/mlx5: E-Switch, Use the correct free() functionOr Gerlitz
We must use kvfree() for something that could have been allocated with vzalloc(), do that. Fixes: 5742df0f7dbe ('net/mlx5: E-Switch, Introduce VST vport ingress/egress ACLs') Fixes: 86d722ad2c3b ('net/mlx5: Use flow steering infrastructure for mlx5_en') Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Reported-by: Ilya Lesokhin <ilyal@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Implement trust vf ndoMohamad Haj Yahia
- Add support to configure trusted vf attribute through trust_vf_ndo. - Upon VF trust setting change we update vport context to refresh allmulti/promisc or any trusted vf attributes that we didn't trust the VF for before. - Lock the eswitch state lock on vport event in order to synchronise the vport context updates , this will prevent contention with vport trust setting change which will trigger vport mac list update. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Implement promiscuous rx modes vf request handlingMohamad Haj Yahia
Add promisc_change as a trigger to vport context change event. Add set vport promisc/allmulti functions to add vport to promiscuous flowtable rules. Upon promisc/allmulti rx mode vf request add the vport to the relevant promiscuous group (Allmulti/Promisc group) so the relevant traffic will be forwarded to it. Upon allmulti vf request add the vport to each existing multicast fdb rule. Upon adding/removing mcast address from a vport, update all other allmulti vports. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Add promiscuous and allmulti FDB flowtable groupsMohamad Haj Yahia
Add promiscuous and allmulti steering groups in FDB table. Besides the full match L2 steering rules group, we added two more groups to catch the "miss" rules traffic: * Allmulti group: One rule that forwards any mcast traffic coming from either uplink or VFs/PF vports * Promisc group: One rule that forwards all unmatched traffic coming from uplink. Needed for downstream privileged VF promisc and allmulti support. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Use vport event handler for vport cleanupMohamad Haj Yahia
Remove the usage of explicit cleanup function and use existing vport change handler. Calling vport change handler while vport is disabled will cleanup the vport resources. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Enable/disable ACL tables on demandMohamad Haj Yahia
Enable ingress/egress ACL tables only when we need to configure ACL rules. Disable ingress/egress ACL tables once all ACL rules are removed. All VF outgoing/incoming traffic need to go through the ingress/egress ACL tables. Adding/Removing these tables on demand will save unnecessary hops in the flow steering when the ACL tables are empty. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Vport ingress/egress ACLs rules for spoofchkMohamad Haj Yahia
Configure ingress and egress vport ACL rules according to spoofchk admin parameters. Ingress ACL flow table rules: if (!spoofchk && !vst) allow all traffic. else : 1) one of the following rules : * if (spoofchk && vst) allow only untagged traffic with smac=original mac sent from the VF. * if (spoofchk && !vst) allow only traffic with smac=original mac sent from the VF. * if (!spoofchk && vst) allow only untagged traffic. 2) drop all traffic that didn't hit #1. Add support for set vf spoofchk ndo. Add non zero mac validation in case of spoofchk to set mac ndo: when setting new mac we need to validate that the new mac is not zero while the spoofchk is on because it is illegal combination. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Vport ingress/egress ACLs rules for VST modeMohamad Haj Yahia
Configure ingress and egress vport ACL rules according to vlan and qos admin parameters. Ingress ACL flow table rules: 1) drop any tagged packet sent from the VF 2) allow other traffic (default behavior) Egress ACL flow table rules: 1) allow only tagged traffic with vlan_tag=vst_vid. 2) drop other traffic. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Introduce VST vport ingress/egress ACLsMohamad Haj Yahia
Create egress/ingress ACLs per VF vport at vport enable. Ingress ACL: - one flow group to drop all tagged traffic in VST mode. Egress ACL: - one flow group that allows only untagged traffic with smac that is equals to the original mac (anti-spoofing). - one flow group that allows only untagged traffic. - one flow group that allows only smac that is equals to the original mac (anti-spoofing). (note: only one of the above group has active rule) - star rule will be used to drop all other traffic. By default no rules are generated, unless VST is explicitly requested. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Fix error flow memory leakMohamad Haj Yahia
Fix memory leak in case query nic vport command failed. Fixes: 81848731ff40 ('net/mlx5: E-Switch, Add SR-IOV (FDB) support') Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: E-Switch, Replace vport spin lock with synchronize_irq()Mohamad Haj Yahia
Vport spin lock can be replaced with synchronize_irq() in the right place, this will remove the need of locking inside irq context. Locking in esw_enable_vport is not required since vport events are yet to be enabled, and at esw_disable_vport it is sufficient to synchronize_irq() to guarantee no further vport events handlers will be scheduled. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-04net/mlx5: Flow steering, Add vport ACL supportMohamad Haj Yahia
Update the relevant flow steering device structs and commands to support vport. Update the flow steering core API to receive vport number. Add ingress and egress ACL flow table name spaces. Add ACL flow table support: * ACL (Access Control List) flow table is a table that contains only allow/drop steering rules. * We have two types of ACL flow tables - ingress and egress. * ACLs handle traffic sent from/to E-Switch FDB table, Ingress refers to traffic sent from Vport to E-Switch and Egress refers to traffic sent from E-Switch to vport. * Ingress ACL flow table allow/drop rules is checked against traffic sent from VF. * Egress ACL flow table allow/drop rules is checked against traffic sent to VF. Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-04-29net/mlx5: Add user chosen levels when allocating flow tablesMaor Gottlieb
Currently, consumers of the flow steering infrastructure can't choose their own flow table levels and are limited to one flow table per level. This just waste levels. Instead, we introduce here the possibility to use multiple flow tables in a level. The user is free to connect these flow tables, while following the rule (FTEs in FT of level x could only point to FTs of level y where y > x). In addition this patch switch the order of the create/destroy flow tables of the NIC(vlan and main). Signed-off-by: Maor Gottlieb <maorg@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-12net/mlx5: Use flow steering infrastructure for mlx5_enMaor Gottlieb
Expose the new flow steering API and remove the old one. Few changes are required: 1. The Ethernet flow steering follows the existing implementation, but uses the new steering API. The old flow steering implementation is removed. 2. Move the E-switch FDB management to use the new API. 3. When driver is loaded call to mlx5_init_fs which initialize the flow steering tree structure, open namespaces for NIC receive and for E-switch FDB. 4. Call to mlx5_cleanup_fs when the driver is unloaded. Signed-off-by: Maor Gottlieb <maorg@mellanox.com> Signed-off-by: Moni Shoua <monis@mellanox.com> Signed-off-by: Matan Barak <matanb@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-03net/mlx5: E-Switch, Introduce get vf statisticsSaeed Mahameed
Add support to get VF statistics using query vport counter command. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-03net/mlx5: E-Switch, Introduce set vport vlan (VST mode)Saeed Mahameed
Add query and modify functions to control client vlan and qos striping or insertion, in E-Switch vports contexts. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-03net/mlx5: E-Switch, Introduce Vport administration functionsSaeed Mahameed
Implement set VF mac/link state and query VF config to be used later in nedev VF ndos or any other management API. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-03net/mlx5: E-Switch, Add SR-IOV (FDB) supportSaeed Mahameed
Enabling E-Switch SRIOV for nvfs+1 vports. Create E-Switch FDB for L2 UC/MC mac steering between VFs/PF and external vport (Uplink). FDB contains forwarding rules such as: UC MAC0 -> vport0(PF). UC MAC1 -> vport1. UC MAC2 -> vport2. MC MACX -> vport0, vport2, Uplink. MC MACY -> vport1, Uplink. For unmatched traffic FDB has the following default rules: Unmached Traffic (src vport != Uplink) -> Uplink. Unmached Traffic (src vport == Uplink) -> vport0(PF). FDB rules population: Each NIC vport (VF) will notify E-Switch manager of its UC/MC vport context changes via modify vport context command, which will be translated to an event that will be handled by E-Switch manager (PF) which will update FDB table accordingly. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-03net/mlx5: Introducing E-Switch and l2 tableSaeed Mahameed
E-Switch is the software entity that represents and manages ConnectX4 inter-HCA ethernet l2 switching. E-Switch has its own Virtual Ports, each Vport/vNIC/VF can be connected to the device through a vport of an e-switch. Each e-switch is managed by one vNIC identified by HCA_CAP.vport_group_manager (usually it is the PF/vport[0]), and its main responsibility is to forward each packet to the right vport. e-Switch needs to manage its own l2-table and FDB tables. L2 table is a flow table that is managed by FW, it is needed for Multi-host (Multi PF) configuration for inter HCA switching between PFs. FDB table is a flow table that is totally managed by e-Switch driver, its main responsibility is to switch packets between e-Swtich internal vports and uplink vport that belong to the same. This patch introduces only e-Swtich l2 table management, FDB managemnt will come later when ethernet SRIOV/VFs will be enabled. preperation for ethernet sriov and l2 table management. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>