2024-02-23HID: wacom: generic: Avoid reporting a serial of '0' to userspaceTatsunosuke Tobita
commit ab41a31dd5e2681803642b6d08590b61867840ec upstream. The xf86-input-wacom driver does not treat '0' as a valid serial number and will drop any input report which contains an MSC_SERIAL = 0 event. The kernel driver already takes care to avoid sending any MSC_SERIAL event if the value of serial[0] == 0 (which is the case for devices that don't actually report a serial number), but this is not quite sufficient. Only the lower 32 bits of the serial get reported to userspace, so if this portion of the serial is zero then there can still be problems. This commit allows the driver to report either the lower 32 bits if they are non-zero or the upper 32 bits otherwise. Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Tatsunosuke Tobita <tatsunosuke.tobita@wacom.com> Fixes: f85c9dc678a5 ("HID: wacom: generic: Support tool ID and additional tool types") CC: stable@vger.kernel.org # v4.10 Signed-off-by: Jiri Kosina <jkosina@suse.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-01-25HID: wacom: Correct behavior when processing some confidence == false touchesJason Gerecke
commit 502296030ec6b0329e00f9fb15018e170cc63037 upstream. There appear to be a few different ways that Wacom devices can deal with confidence: 1. If the device looses confidence in a touch, it will first clear the tipswitch flag in one report, and then clear the confidence flag in a second report. This behavior is used by e.g. DTH-2452. 2. If the device looses confidence in a touch, it will clear both the tipswitch and confidence flags within the same report. This behavior is used by some AES devices. 3. If the device looses confidence in a touch, it will clear *only* the confidence bit. The tipswitch bit will remain set so long as the touch is tracked. This behavior may be used in future devices. The driver does not currently handle situation 3 properly. Touches that loose confidence will remain "in prox" and essentially frozen in place until the tipswitch bit is finally cleared. Not only does this result in userspace seeing a stuck touch, but it also prevents pen arbitration from working properly (the pen won't send events until all touches are up, but we don't currently process events from non-confident touches). This commit centralizes the checking of the confidence bit in the wacom_wac_finger_slot() function and has 'prox' depend on it. In the case where situation 3 is encountered, the treat the touch as though it was removed, allowing both userspace and the pen arbitration to act normally. Signed-off-by: Tatsunosuke Tobita <tatsunosuke.tobita@wacom.com> Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Fixes: 7fb0413baa7f ("HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts") Cc: stable@vger.kernel.org Signed-off-by: Jiri Kosina <jkosina@suse.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-09-23HID: wacom: remove the battery when the EKR is offAaron Armstrong Skomra
commit 9ac6678b95b0dd9458a7a6869f46e51cd55a1d84 upstream. Currently the EKR battery remains even after we stop getting information from the device. This can lead to a stale battery persisting indefinitely in userspace. The remote sends a heartbeat every 10 seconds. Delete the battery if we miss two heartbeats (after 21 seconds). Restore the battery once we see a heartbeat again. Signed-off-by: Aaron Skomra <skomra@gmail.com> Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Fixes: 9f1015d45f62 ("HID: wacom: EKR: attach the power_supply on first connection") CC: stable@vger.kernel.org Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-07-27HID: wacom: Use ktime_t rather than int when dealing with timestampsJason Gerecke
commit 9a6c0e28e215535b2938c61ded54603b4e5814c5 upstream. Code which interacts with timestamps needs to use the ktime_t type returned by functions like ktime_get. The int type does not offer enough space to store these values, and attempting to use it is a recipe for problems. In this particular case, overflows would occur when calculating/storing timestamps leading to incorrect values being reported to userspace. In some cases these bad timestamps cause input handling in userspace to appear hung. Link: https://gitlab.freedesktop.org/libinput/libinput/-/issues/901 Fixes: 17d793f3ed53 ("HID: wacom: insert timestamp to packed Bluetooth (BT) events") CC: stable@vger.kernel.org Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com> Link: https://lore.kernel.org/r/20230608213828.2108-1-jason.gerecke@wacom.com Signed-off-by: Benjamin Tissoires <bentiss@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-06-09HID: wacom: avoid integer overflow in wacom_intuos_inout()Nikita Zhandarovich
commit bd249b91977b768ea02bf84d04625d2690ad2b98 upstream. If high bit is set to 1 in ((data[3] & 0x0f << 28), after all arithmetic operations and integer promotions are done, high bits in wacom->serial[idx] will be filled with 1s as well. Avoid this, albeit unlikely, issue by specifying left operand's __u64 type for the right operand. Found by Linux Verification Center (linuxtesting.org) with static analysis tool SVACE. Fixes: 3bea733ab212 ("USB: wacom tablet driver reorganization") Signed-off-by: Nikita Zhandarovich <n.zhandarovich@fintech.ru> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Cc: stable@vger.kernel.org Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-05-30HID: wacom: add three styli to wacom_intuos_get_tool_typePing Cheng
commit bfdc750c4cb2f3461b9b00a2755e2145ac195c9a upstream. We forgot to add the 3D pen ID a year ago. There are two new pro pen IDs to be added. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-05-30HID: wacom: Add new Intuos Pro Small (PTH-460) device IDsPing Cheng
commit 0627f3df95e1609693f89e7ceb4156ac5db6e358 upstream. Add the new PIDs to wacom_wac.c to support the new model in the Intuos Pro series. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Tested-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Cc: Ping Cheng <pinglinux@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-05-30HID: wacom: Force pen out of prox if no events have been received in a whileJason Gerecke
commit 94b179052f95c294d83e9c9c34f7833cf3cd4305 upstream. Prox-out events may not be reliably sent by some AES firmware. This can cause problems for users, particularly due to arbitration logic disabling touch input while the pen is in prox. This commit adds a timer which is reset every time a new prox event is received. When the timer expires we check to see if the pen is still in prox and force it out if necessary. This is patterend off of the same solution used by 'hid-letsketch' driver which has a similar problem. Link: https://github.com/linuxwacom/input-wacom/issues/310 Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Cc: Ping Cheng <pinglinux@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-05-30HID: wacom: generic: Set battery quirk only when we see battery dataJason Gerecke
[ Upstream commit bea407a427baa019758f29f4d31b26f008bb8cc6 ] Some devices will include battery status usages in the HID descriptor but we won't see that battery data for one reason or another. For example, AES sensors won't send battery data unless an AES pen is in proximity. If a user does not have an AES pen but instead only interacts with the AES touchscreen with their fingers then there is no need for us to create a battery object. Similarly, if a family of peripherals shares the same HID descriptor between wired-only and wireless-capable SKUs, users of the former may never see a battery event and will not want a power_supply object created. Link: https://bugzilla.kernel.org/show_bug.cgi?id=217062 Link: https://gitlab.gnome.org/GNOME/gnome-control-center/-/issues/2354 Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Tested-by: Mario Limonciello <mario.limonciello@amd.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Sasha Levin <sashal@kernel.org>
2023-05-17HID: wacom: insert timestamp to packed Bluetooth (BT) eventsPing Cheng
commit 17d793f3ed53080dab6bbeabfc82de890c901001 upstream. To fully utilize the BT polling/refresh rate, a few input events are sent together to reduce event delay. This causes issue to the timestamp generated by input_sync since all the events in the same packet would pretty much have the same timestamp. This patch inserts time interval to the events by averaging the total time used for sending the packet. This decision was mainly based on observing the actual time interval between each BT polling. The interval doesn't seem to be constant, due to the network and system environment. So, using solutions other than averaging doesn't end up with valid timestamps. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-05-17HID: wacom: Set a default resolution for older tabletsPing Cheng
commit 08a46b4190d345544d04ce4fe2e1844b772b8535 upstream. Some older tablets may not report physical maximum for X/Y coordinates. Set a default to prevent undefined resolution. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Link: https://lore.kernel.org/r/20230409164229.29777-1-ping.cheng@wacom.com Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2023-01-18HID: wacom: Ensure bootloader PID is usable in hidraw modeJason Gerecke
commit 1db1f392591aff13fd643f0ec7c1d5e27391d700 upstream. Some Wacom devices have a special "bootloader" mode that is used for firmware flashing. When operating in this mode, the device cannot be used for input, and the HID descriptor is not able to be processed by the driver. The driver generates an "Unknown device_type" warning and then returns an error code from wacom_probe(). This is a problem because userspace still needs to be able to interact with the device via hidraw to perform the firmware flash. This commit adds a non-generic device definition for 056a:0094 which is used when devices are in "bootloader" mode. It marks the devices with a special BOOTLOADER type that is recognized by wacom_probe() and wacom_raw_event(). When we see this type we ensure a hidraw device is created and otherwise keep our hands off so that userspace is in full control. Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Tested-by: Tatsunosuke Tobita <tatsunosuke.tobita@wacom.com> Cc: <stable@vger.kernel.org> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-08-25HID: wacom: Don't register pad_input for touch switchPing Cheng
commit d6b675687a4ab4dba684716d97c8c6f81bf10905 upstream. Touch switch state is received through WACOM_PAD_FIELD. However, it is reported by touch_input. Don't register pad_input if no other pad events require the interface. Cc: stable@vger.kernel.org Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-08-25HID: wacom: Only report rotation for art penPing Cheng
commit 7ccced33a0ba39b0103ae1dfbf7f1dffdc0a1bc2 upstream. The generic routine, wacom_wac_pen_event, turns rotation value 90 degree anti-clockwise before posting the events. This non-zero event trggers a non-zero ABS_Z event for non art pen tools. However, HID_DG_TWIST is only supported by art pen. [jkosina@suse.cz: fix build: add missing brace] Cc: stable@vger.kernel.org Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-01-27HID: wacom: Avoid using stale array indicies to read contact countJason Gerecke
commit 20f3cf5f860f9f267a6a6e5642d3d0525edb1814 upstream. If we ever see a touch report with contact count data we initialize several variables used to read the contact count in the pre-report phase. These variables are never reset if we process a report which doesn't contain a contact count, however. This can cause the pre- report function to trigger a read of arbitrary memory (e.g. NULL if we're lucky) and potentially crash the driver. This commit restores resetting of the variables back to default "none" values that were used prior to the commit mentioned below. Link: https://github.com/linuxwacom/input-wacom/issues/276 Fixes: 003f50ab673c (HID: wacom: Update last_slot_field during pre_report phase) CC: stable@vger.kernel.org Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-01-27HID: wacom: Ignore the confidence flag when a touch is removedJason Gerecke
commit df03e9bd6d4806619b4cdc91a3d7695818a8e2b7 upstream. AES hardware may internally re-classify a contact that it thought was intentional as a palm. Intentional contacts are reported as "down" with the confidence bit set. When this re-classification occurs, however, the state transitions to "up" with the confidence bit cleared. This kind of transition appears to be legal according to Microsoft docs, but we do not handle it correctly. Because the confidence bit is clear, we don't call `wacom_wac_finger_slot` and update userspace. This causes hung touches that confuse userspace and interfere with pen arbitration. This commit adds a special case to ignore the confidence flag if a contact is reported as removed. This ensures we do not leave a hung touch if one of these re-classification events occured. Ideally we'd have some way to also let userspace know that the touch has been re-classified as a palm and needs to be canceled, but that's not possible right now :) Link: https://github.com/linuxwacom/input-wacom/issues/288 Fixes: 7fb0413baa7f (HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts) CC: stable@vger.kernel.org Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-01-27HID: wacom: Reset expected and received contact counts at the same timeJason Gerecke
commit 546e41ac994cc185ef3de610ca849a294b5df3ba upstream. These two values go hand-in-hand and must be valid for the driver to behave correctly. We are currently lazy about updating the values and rely on the "expected" code flow to take care of making sure they're valid at the point they're needed. The "expected" flow changed somewhat with commit f8b6a74719b5 ("HID: wacom: generic: Support multiple tools per report"), however. This led to problems with the DTH-2452 due (in part) to *all* contacts being fully processed -- even those past the expected contact count. Specifically, the received count gets reset to 0 once all expected fingers are processed, but not the expected count. The rest of the contacts in the report are then *also* processed since now the driver thinks we've only processed 0 of N expected contacts. Later commits such as 7fb0413baa7f (HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts) worked around the DTH-2452 issue by skipping the invalid contacts at the end of the report, but this is not a complete fix. The confidence flag cannot be relied on when a contact is removed (see the following patch), and dealing with that condition re-introduces the DTH-2452 issue unless we also address this contact count laziness. By resetting expected and received counts at the same time we ensure the driver understands that there are 0 more contacts expected in the report. Similarly, we also make sure to reset the received count if for some reason we're out of sync in the pre-report phase. Link: https://github.com/linuxwacom/input-wacom/issues/288 Fixes: f8b6a74719b5 ("HID: wacom: generic: Support multiple tools per report") CC: stable@vger.kernel.org Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2021-12-01HID: wacom: Use "Confidence" flag to prevent reporting invalid contactsJason Gerecke
commit 7fb0413baa7f8a04caef0c504df9af7e0623d296 upstream. The HID descriptor of many of Wacom's touch input devices include a "Confidence" usage that signals if a particular touch collection contains useful data. The driver does not look at this flag, however, which causes even invalid contacts to be reported to userspace. A lucky combination of kernel event filtering and device behavior (specifically: contact ID 0 == invalid, contact ID >0 == valid; and order all data so that all valid contacts are reported before any invalid contacts) spare most devices from any visibly-bad behavior. The DTH-2452 is one example of an unlucky device that misbehaves. It uses ID 0 for both the first valid contact and all invalid contacts. Because we report both the valid and invalid contacts, the kernel reports that contact 0 first goes down (valid) and then goes up (invalid) in every report. This causes ~100 clicks per second simply by touching the screen. This patch inroduces new `confidence` flag in our `hid_data` structure. The value is initially set to `true` at the start of a report and can be set to `false` if an invalid touch usage is seen. Link: https://github.com/linuxwacom/input-wacom/issues/270 Fixes: f8b6a74719b5 ("HID: wacom: generic: Support multiple tools per report") Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Tested-by: Joshua Dickens <joshua.dickens@wacom.com> Cc: <stable@vger.kernel.org> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2021-10-17HID: wacom: Add new Intuos BT (CTL-4100WL/CTL-6100WL) device IDsJoshua-Dickens
[ Upstream commit 0c8fbaa553077630e8eae45bd9676cfc01836aeb ] Add the new PIDs to wacom_wac.c to support the new models in the Intuos series. [jkosina@suse.cz: fix changelog] Signed-off-by: Joshua Dickens <joshua.dickens@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Sasha Levin <sashal@kernel.org>
2021-08-04HID: wacom: Re-enable touch by default for Cintiq 24HDT / 27QHDTJason Gerecke
commit 6ca2350e11f09d5d3e53777d1eff8ff6d300ed93 upstream. Commit 670e90924bfe ("HID: wacom: support named keys on older devices") added support for sending named events from the soft buttons on the 24HDT and 27QHDT. In the process, however, it inadvertantly disabled the touchscreen of the 24HDT and 27QHDT by default. The `wacom_set_shared_values` function would normally enable touch by default but because it checks the state of the non-shared `has_mute_touch_switch` flag and `wacom_setup_touch_input_capabilities` sets the state of the /shared/ version, touch ends up being disabled by default. This patch sets the non-shared flag, letting `wacom_set_shared_values` take care of copying the value over to the shared version and setting the default touch state to "on". Fixes: 670e90924bfe ("HID: wacom: support named keys on older devices") CC: stable@vger.kernel.org # 5.4+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2021-04-28HID: wacom: Assign boolean values to a bool variableJiapeng Zhong
[ Upstream commit e29c62ffb008829dc8bcc0a2ec438adc25a8255e ] Fix the following coccicheck warnings: ./drivers/hid/wacom_wac.c:2536:2-6: WARNING: Assignment of 0/1 to bool variable. Reported-by: Abaci Robot <abaci@linux.alibaba.com> Signed-off-by: Jiapeng Zhong <abaci-bugfix@linux.alibaba.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Sasha Levin <sashal@kernel.org>
2021-04-21HID: wacom: set EV_KEY and EV_ABS only for non-HID_GENERIC type of devicesPing Cheng
commit 276559d8d02c2709281578976ca2f53bc62063d4 upstream. Valid HID_GENERIC type of devices set EV_KEY and EV_ABS by wacom_map_usage. When *_input_capabilities are reached, those devices should already have their proper EV_* set. EV_KEY and EV_ABS only need to be set for non-HID_GENERIC type of devices in *_input_capabilities. Devices that don't support HID descitoprs will pass back to hid-input for registration without being accidentally rejected by the introduction of patch: "Input: refuse to register absolute devices without absinfo" Fixes: 6ecfe51b4082 ("Input: refuse to register absolute devices without absinfo") Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <Jason.Gerecke@wacom.com> Tested-by: Juan Garrido <Juan.Garrido@wacom.com> CC: stable@vger.kernel.org Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2021-03-04HID: wacom: Ignore attempts to overwrite the touch_max value from HIDJason Gerecke
commit 88f38846bfb1a452a3d47e38aeab20a4ceb74294 upstream. The `wacom_feature_mapping` function is careful to only set the the touch_max value a single time, but this care does not extend to the `wacom_wac_finger_event` function. In particular, if a device sends multiple HID_DG_CONTACTMAX items in a single feature report, the driver will end up retaining the value of last item. The HID descriptor for the Cintiq Companion 2 does exactly this. It incorrectly sets a "Report Count" of 2, which will cause the driver to process two HID_DG_CONTACTCOUNT items. The first item has the actual count, while the second item should have been declared as a constant zero. The constant zero is the value the driver ends up using, however, since it is the last HID_DG_CONTACTCOUNT in the report. Report ID (16), Usage (Contact Count Maximum), ; Contact count maximum (55h, static value) Report Count (2), Logical Maximum (10), Feature (Variable), To address this, we add a check that the touch_max is not already set within the `wacom_wac_finger_event` function that processes the HID_DG_TOUCHMAX item. We emit a warning if the value is set and ignore the updated value. This could potentially cause problems if there is a tablet which has a similar issue but requires the last item to be used. This is unlikely, however, since it would have to have a different non-zero value for HID_DG_CONTACTMAX earlier in the same report, which makes no sense except in the case of a firmware bug. Note that cases where the HID_DG_CONTACTMAX items are in different reports is already handled (and similarly ignored) by `wacom_feature_mapping` as mentioned above. Link: https://github.com/linuxwacom/input-wacom/issues/223 Fixes: 184eccd40389 ("HID: wacom: generic: read HID_DG_CONTACTMAX from any feature report") Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> CC: stable@vger.kernel.org Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-11-05HID: wacom: Avoid entering wacom_wac_pen_report for pad / batteryJason Gerecke
commit d9216d753b2b1406b801243b12aaf00a5ce5b861 upstream. It has recently been reported that the "heartbeat" report from devices like the 2nd-gen Intuos Pro (PTH-460, PTH-660, PTH-860) or the 2nd-gen Bluetooth-enabled Intuos tablets (CTL-4100WL, CTL-6100WL) can cause the driver to send a spurious BTN_TOUCH=0 once per second in the middle of drawing. This can result in broken lines while drawing on Chrome OS. The source of the issue has been traced back to a change which modified the driver to only call `wacom_wac_pad_report()` once per report instead of once per collection. As part of this change, pad-handling code was removed from `wacom_wac_collection()` under the assumption that the `WACOM_PEN_FIELD` and `WACOM_TOUCH_FIELD` checks would not be satisfied when a pad or battery collection was being processed. To be clear, the macros `WACOM_PAD_FIELD` and `WACOM_PEN_FIELD` do not currently check exclusive conditions. In fact, most "pad" fields will also appear to be "pen" fields simply due to their presence inside of a Digitizer application collection. Because of this, the removal of the check from `wacom_wac_collection()` just causes pad / battery collections to instead trigger a call to `wacom_wac_pen_report()` instead. The pen report function in turn resets the tip switch state just prior to exiting, resulting in the observed BTN_TOUCH=0 symptom. To correct this, we restore a version of the `WACOM_PAD_FIELD` check in `wacom_wac_collection()` and return early. This effectively prevents pad / battery collections from being reported until the very end of the report as originally intended. Fixes: d4b8efeb46d9 ("HID: wacom: generic: Correct pad syncing") Cc: stable@vger.kernel.org # v4.17+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Tested-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-05-14HID: wacom: Report 2nd-gen Intuos Pro S center button status over BTJason Gerecke
commit dcce8ef8f70a8e38e6c47c1bae8b312376c04420 upstream. The state of the center button was not reported to userspace for the 2nd-gen Intuos Pro S when used over Bluetooth due to the pad handling code not being updated to support its reduced number of buttons. This patch uses the actual number of buttons present on the tablet to assemble a button state bitmap. Link: https://github.com/linuxwacom/xf86-input-wacom/issues/112 Fixes: cd47de45b855 ("HID: wacom: Add 2nd gen Intuos Pro Small support") Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Cc: stable@vger.kernel.org # v5.3+ Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-05-14Revert "HID: wacom: generic: read the number of expected touches on a per ↵Jason Gerecke
collection basis" commit b43f977dd281945960c26b3ef67bba0fa07d39d9 upstream. This reverts commit 15893fa40109f5e7c67eeb8da62267d0fdf0be9d. The referenced commit broke pen and touch input for a variety of devices such as the Cintiq Pro 32. Affected devices may appear to work normally for a short amount of time, but eventually loose track of actual touch state and can leave touch arbitration enabled which prevents the pen from working. The commit is not itself required for any currently-available Bluetooth device, and so we revert it to correct the behavior of broken devices. This breakage occurs due to a mismatch between the order of collections and the order of usages on some devices. This commit tries to read the contact count before processing events, but will fail if the contact count does not occur prior to the first logical finger collection. This is the case for devices like the Cintiq Pro 32 which place the contact count at the very end of the report. Without the contact count set, touches will only be partially processed. The `wacom_wac_finger_slot` function will not open any slots since the number of contacts seen is greater than the expectation of 0, but we will still end up calling `input_mt_sync_frame` for each finger anyway. This can cause problems for userspace separate from the issue currently taking place in the kernel. Only once all of the individual finger collections have been processed do we finally get to the enclosing collection which contains the contact count. The value ends up being used for the *next* report, however. This delayed use of the contact count can cause the driver to loose track of the actual touch state and believe that there are contacts down when there aren't. This leaves touch arbitration enabled and prevents the pen from working. It can also cause userspace to incorrectly treat single- finger input as gestures. Link: https://github.com/linuxwacom/input-wacom/issues/146 Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Fixes: 15893fa40109 ("HID: wacom: generic: read the number of expected touches on a per collection basis") Cc: stable@vger.kernel.org # 5.3+ Signed-off-by: Jiri Kosina <jkosina@suse.cz> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-02-01HID: wacom: Recognize new MobileStudio Pro PIDJason Gerecke
[ Upstream commit fe4e940f0f91b4a506f048b42e00386f5ad322b6 ] A new PID is in use for repaired MobileStudio Pro devices. Add it to the list of devices that need special-casing in wacom_wac_pad_event. Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
2019-11-06HID: wacom: generic: Treat serial number and related fields as unsignedJason Gerecke
The HID descriptors for most Wacom devices oddly declare the serial number and other related fields as signed integers. When these numbers are ingested by the HID subsystem, they are automatically sign-extended into 32-bit integers. We treat the fields as unsigned elsewhere in the kernel and userspace, however, so this sign-extension causes problems. In particular, the sign-extended tool ID sent to userspace as ABS_MISC does not properly match unsigned IDs used by xf86-input-wacom and libwacom. We introduce a function 'wacom_s32tou' that can undo the automatic sign extension performed by 'hid_snto32'. We call this function when processing the serial number and related fields to ensure that we are dealing with and reporting the unsigned form. We opt to use this method rather than adding a descriptor fixup in 'wacom_hid_usage_quirk' since it should be more robust in the face of future devices. Ref: https://github.com/linuxwacom/input-wacom/issues/134 Fixes: f85c9dc678 ("HID: wacom: generic: Support tool ID and additional tool types") CC: <stable@vger.kernel.org> # v4.10+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-09-22Merge branch 'for-5.4/wacom' into for-linusJiri Kosina
- MobileStudio Pro 13 support, from Ping Cheng - a few other assorted fixes Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-09-05HID: wacom: add new MobileStudio Pro 13 supportPing Cheng
wacom_wac_pad_event is the only routine we need to update. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20HID: wacom: support named keys on older devicesAaron Armstrong Skomra
Some Wacom devices have keys with predefined meanings. However, when support was originally added for these devices, the codes for these keys were not available yet. These keys were thus reported with the numbered KEY_PROG* range. Some missing key codes were added with commit 4eb220cb35a9 ("HID: wacom: generic: add 3 tablet touch keys") and we are now able to report the proper key codes. We continue to report the original KEY_PROG codes so as not to break any unknown applications that may depend on them. Also, to support the touch key, track its state in the pad report. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Link: https://gitlab.freedesktop.org/libinput/libinput/merge_requests/155 Link: https://github.com/linuxwacom/xf86-input-wacom/pull/46 Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20HID: wacom: Fix several minor compiler warningsJason Gerecke
Addresses a few issues that were noticed when compiling with non-default warnings enabled. The trimmed-down warnings in the order they are fixed below are: * declaration of 'size' shadows a parameter * '%s' directive output may be truncated writing up to 5 bytes into a region of size between 1 and 64 * pointer targets in initialization of 'char *' from 'unsigned char *' differ in signedness * left shift of negative value Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-20HID: wacom: correct misreported EKR ring valuesAaron Armstrong Skomra
The EKR ring claims a range of 0 to 71 but actually reports values 1 to 72. The ring is used in relative mode so this change should not affect users. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Fixes: 72b236d60218f ("HID: wacom: Add support for Express Key Remote.") Cc: <stable@vger.kernel.org> # v4.3+ Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-19HID: wacom: Correct distance scale for 2nd-gen Intuos devicesJason Gerecke
Distance values reported by 2nd-gen Intuos tablets are on an inverted scale (0 == far, 63 == near). We need to change them over to a normal scale before reporting to userspace or else userspace drivers and applications can get confused. Ref: https://github.com/linuxwacom/input-wacom/issues/98 Fixes: eda01dab53 ("HID: wacom: Add four new Intuos devices") Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Cc: <stable@vger.kernel.org> # v4.4+ Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-13HID: wacom: add back changes dropped in merge commitAaron Armstrong Skomra
Merge commit 74acee309fb2 ("Merge branches 'for-5.2/fixes', 'for-5.3/doc', 'for-5.3/ish', 'for-5.3/logitech' and 'for-5.3/wacom' into for-linus") inadvertently dropped this change from commit 912c6aa67ad4 ("HID: wacom: Add 2nd gen Intuos Pro Small support"). Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-08-05HID: wacom: fix bit shift for Cintiq Companion 2Aaron Armstrong Skomra
The bit indicating BTN_6 on this device is overshifted by 2 bits, resulting in the incorrect button being reported. Also fix copy-paste mistake in comments. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Link: https://github.com/linuxwacom/xf86-input-wacom/issues/71 Fixes: c7f0522a1ad1 ("HID: wacom: Slim down wacom_intuos_pad processing") Cc: <stable@vger.kernel.org> # v4.5+ Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-07-10Merge branches 'for-5.2/fixes', 'for-5.3/doc', 'for-5.3/ish', ↵Jiri Kosina
'for-5.3/logitech' and 'for-5.3/wacom' into for-linus
2019-07-02HID: wacom: generic: add touchring adjustment for 2nd Gen Pro SmallAaron Armstrong Skomra
Add the product ID for the 2nd Generation Intuos Pro Small to the touchring coordinate adjustment block. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-06-26HID: wacom: add new MobileStudio Pro supportPing Cheng
Add product ID for new MobileStudio Pro. Signed-off-by: Ping Cheng <ping.cheng@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13Merge branch 'for-linus' of ↵Linus Torvalds
git://git.kernel.org/pub/scm/linux/kernel/git/hid/hid Pull HID fixes from Jiri Kosina: - regression fixes (reverts) for module loading changes that turned out to be incompatible with some userspace, from Benjamin Tissoires - regression fix for special Logitech unifiying receiver 0xc52f, from Hans de Goede - a few device ID additions to logitech driver, from Hans de Goede - fix for Bluetooth support on 2nd-gen Wacom Intuos Pro, from Jason Gerecke * 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/hid/hid: HID: logitech-dj: Fix 064d:c52f receiver support Revert "HID: core: Call request_module before doing device_add" Revert "HID: core: Do not call request_module() in async context" Revert "HID: Increase maximum report size allowed by hid_field_extract()" HID: a4tech: fix horizontal scrolling HID: hyperv: Add a module description line HID: logitech-hidpp: Add support for the S510 remote control HID: multitouch: handle faulty Elo touch device HID: wacom: Sync INTUOSP2_BT touch state after each frame if necessary HID: wacom: Correct button numbering 2nd-gen Intuos Pro over Bluetooth HID: wacom: Send BTN_TOUCH in response to INTUOSP2_BT eraser contact HID: wacom: Don't report anything prior to the tool entering range HID: wacom: Don't set tool type until we're in range HID: rmi: Use SET_REPORT request on control endpoint for Acer Switch 3 and 5 HID: logitech-hidpp: add support for the MX5500 keyboard HID: logitech-dj: add support for the Logitech MX5500's Bluetooth Mini-Receiver HID: i2c-hid: add iBall Aer3 to descriptor override
2019-06-13HID: wacom: generic: read the number of expected touches on a per collection ↵Aaron Armstrong Skomra
basis Bluetooth connections may contain more than one set of touches, or a partial set of touches, in one report. Set the number of expected touches when reading a collection instead of once per report (in the pre-report function). Accordingly, reset the number of touches expected after each sync. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13HID: wacom: generic: support the 'report valid' usage for touchAaron Armstrong Skomra
Finger data is separated into chunks in our Bluetooth report, where each report contains the same number of chunks. Those chunks are not aligned in any particular way to a set of finger touches. That is, the first half of a group of simultaneous touches may be in one chunk at the end of a report and the second half could be at the beginning of the next report. Also some chunks contain no data and potentially some chunks could contain leftover (bad) data. Introduce and process the WACOM_HID_WT_REPORT_VALID usage that the device uses to let us know if we should process a chunk of data. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13HID: wacom: generic: read HID_DG_CONTACTMAX from any feature reportAaron Armstrong Skomra
In the generic code path, HID_DG_CONTACTMAX was previously only read from the second byte of report 0x23. Another report (0x82) has the HID_DG_CONTACTMAX in the higher nibble of the third byte. We should support reading the value of HID_DG_CONTACTMAX no matter what report we are reading or which position that value is in. To do this we submit the feature report as a event report using hid_report_raw_event(). Our modified finger event path records the value of HID_DG_CONTACTMAX when it sees that usage. Fixes: 8ffffd5212846 ("HID: wacom: fix timeout on probe for some wacoms") Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-06-13HID: wacom: Add 2nd gen Intuos Pro Small supportAaron Armstrong Skomra
The existing INTUOSP2_BT device class supports LEDs and this device does not. A new device class enum entry, "INTUOSP2S_BT", is created to avoid the INTUOSP2_BT LED code. Signed-off-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-05-30treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 152Thomas Gleixner
Based on 1 normalized pattern(s): this program is free software you can redistribute it and or modify it under the terms of the gnu general public license as published by the free software foundation either version 2 of the license or at your option any later version extracted by the scancode license scanner the SPDX license identifier GPL-2.0-or-later has been chosen to replace the boilerplate/reference in 3029 file(s). Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Reviewed-by: Allison Randal <allison@lohutok.net> Cc: linux-spdx@vger.kernel.org Link: https://lkml.kernel.org/r/20190527070032.746973796@linutronix.de Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-17HID: wacom: Sync INTUOSP2_BT touch state after each frame if necessaryJason Gerecke
The Bluetooth interface of the 2nd-gen Intuos Pro batches together four independent "frames" of finger data into a single report. Each frame is essentially equivalent to a single USB report, with the up-to-10 fingers worth of information being spread across two frames. At the moment the driver only calls `input_sync` after processing all four frames have been processed, which can result in the driver sending multiple updates for a single slot within the same SYN_REPORT. This can confuse userspace, so modify the driver to sync more often if necessary (i.e., after reporting the state of all fingers). Fixes: 4922cd26f03c ("HID: wacom: Support 2nd-gen Intuos Pro's Bluetooth classic interface") Cc: <stable@vger.kernel.org> # 4.11+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-05-17HID: wacom: Correct button numbering 2nd-gen Intuos Pro over BluetoothJason Gerecke
The button numbering of the 2nd-gen Intuos Pro is not consistent between the USB and Bluetooth interfaces. Over USB, the HID_GENERIC codepath enumerates the eight ExpressKeys first (BTN_0 - BTN_7) followed by the center modeswitch button (BTN_8). The Bluetooth codepath, however, has the center modeswitch button as BTN_0 and the the eight ExpressKeys as BTN_1 - BTN_8. To ensure userspace button mappings do not change depending on how the tablet is connected, modify the Bluetooth codepath to report buttons in the same order as USB. To ensure the mode switch LED continues to toggle in response to the mode switch button, the `wacom_is_led_toggled` function also requires a small update. Link: https://github.com/linuxwacom/input-wacom/pull/79 Fixes: 4922cd26f03c ("HID: wacom: Support 2nd-gen Intuos Pro's Bluetooth classic interface") Cc: <stable@vger.kernel.org> # 4.11+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Skomra <aaron.skomra@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-05-17HID: wacom: Send BTN_TOUCH in response to INTUOSP2_BT eraser contactJason Gerecke
The Bluetooth reports from the 2nd-gen Intuos Pro have separate bits for indicating if the tip or eraser is in contact with the tablet. At the moment, only the tip contact bit controls the state of the BTN_TOUCH event. This prevents the eraser from working as expected. This commit changes the driver to send BTN_TOUCH whenever either the tip or eraser contact bit is set. Fixes: 4922cd26f03c ("HID: wacom: Support 2nd-gen Intuos Pro's Bluetooth classic interface") Cc: <stable@vger.kernel.org> # 4.11+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Skomra <aaron.skomra@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-05-17HID: wacom: Don't report anything prior to the tool entering rangeJason Gerecke
If the tool spends some time in prox before entering range, a series of events (e.g. ABS_DISTANCE, MSC_SERIAL) can be sent before we or userspace have any clue about the pen whose data is being reported. We need to hold off on reporting anything until the pen has entered range. Since we still want to report events that occur "in prox" after the pen has *left* range we use 'wacom-tool[0]' as the indicator that the pen did at one point enter range and provide us/userspace with tool type and serial number information. Fixes: a48324de6d4d ("HID: wacom: Bluetooth IRQ for Intuos Pro should handle prox/range") Cc: <stable@vger.kernel.org> # 4.11+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
2019-05-17HID: wacom: Don't set tool type until we're in rangeJason Gerecke
The serial number and tool type information that is reported by the tablet while a pen is merely "in prox" instead of fully "in range" can be stale and cause us to report incorrect tool information. Serial number, tool type, and other information is only valid once the pen comes fully in range so we should be careful to not use this information until that point. In particular, this issue may cause the driver to incorectly report BTN_TOOL_RUBBER after switching from the eraser tool back to the pen. Fixes: a48324de6d4d ("HID: wacom: Bluetooth IRQ for Intuos Pro should handle prox/range") Cc: <stable@vger.kernel.org> # 4.11+ Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com> Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>