summaryrefslogtreecommitdiffstats
path: root/drivers/spi/spi-bcm63xx.c
AgeCommit message (Collapse)Author
2012-08-25Merge branch 'upstream' of git://git.linux-mips.org/pub/scm/ralf/upstream-linusLinus Torvalds
Pull MIPS fixes from Ralf Baechle: "Random fixes across the MIPS tree. The two hotspots are several bugs in the module loader and the ath79 SOC support; also noteworthy is the restructuring of the code to synchronize CPU timers across CPUs on startup; the old code recently ceased to work due to unrelated changes. All except one of these patches have sat for a significant time in linux-next for testing." * 'upstream' of git://git.linux-mips.org/pub/scm/ralf/upstream-linus: MIPS: pci-ar724x: avoid data bus error due to a missing PCIe module MIPS: Malta: Delete duplicate PCI fixup. MIPS: ath79: don't hardcode the unavailability of the DSP ASE MIPS: Synchronize MIPS count one CPU at a time MIPS: BCM63xx: Fix SPI message control register handling for BCM6338/6348. MIPS: Module: Deal with malformed HI16/LO16 relocation sequences. MIPS: Fix race condition in module relocation code. MIPS: Fix memory leak in error path of HI16/LO16 relocation handling. MIPS: MTX-1: Add udelay to mtx1_pci_idsel MIPS: ath79: select HAVE_CLK MIPS: ath79: Use correct IRQ number for the OHCI controller on AR7240 MIPS: ath79: Fix number of GPIO lines for AR724[12] MIPS: Octeon: Fix broken interrupt controller code.
2012-08-17MIPS: BCM63xx: Fix SPI message control register handling for BCM6338/6348.Florian Fainelli
BCM6338 and BCM6348 have a message control register width of 8 bits, instead of 16-bits like what the SPI driver assumes right now. Also the SPI message type shift value of 14 is actually 6 for these SoCs. This resulted in transmit FIFO corruption because we were writing 16-bits to an 8-bits wide register, thus spanning on the first byte of the transmit FIFO, which had already been filed in bcm63xx_spi_fill_txrx_fifo(). Fix this by passing the message control register width and message type shift through platform data back to the SPI driver so that it can use it properly. Signed-off-by: Florian Fainelli <florian@openwrt.org> Cc: linux-mips@linux-mips.org Cc: grant.likely@secretlab.ca Cc: spi-devel-general@lists.sourceforge.net Cc: jonas.gorski@gmail.com Patchwork: https://patchwork.linux-mips.org/patch/3983/ Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
2012-08-13spi/bcm63xx: Ensure that memory is freed only after it is no longer usedGuenter Roeck
The call to spi_unregister_master() in the device remove function frees device memory, and with it any device local data. However, device local data is still accessed after the call to spi_unregister_master(). Acquire a reference to the SPI device and release it after cleanup is complete to solve the problem. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2012-07-23spi/bcm63xx: fix clock configuration selectionFlorian Fainelli
We are currently using an inferior or equal operator for comparing the transfer frequency with the clock frequency table. Because of this, we always end up selecting 20Mhz as a frequency, due to the inequality transfer hz <= 20 Mhz being always true. Fix this by reversing the inequality, which is how the comparison should be done. Signed-off-by: Florian Fainelli <florian@openwrt.org> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2012-04-27spi/bcm63xx: set master driver mode_bits.Florian Fainelli
We were not properly advertising the MODE bits supported by this driver, fix that. Signed-off-by: Florian Fainelli <florian@openwrt.org> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
2012-04-27spi/bcm63xx: don't use the stopping stateFlorian Fainelli
We do not need to use a flag to indicate if the master driver is stopping it is sufficient to perform spi master unregistering in the platform driver's remove function. Signed-off-by: Florian Fainelli <florian@openwrt.org> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
2012-04-27spi/bcm63xx: convert to the pump message infrastructureFlorian Fainelli
This patch converts the bcm63xx SPI driver to use the SPI infrastructure pump message queue. Since we were previously sleeping in the SPI driver's transfer() function (which is not allowed) this is now fixed as well. To complete that conversion a certain number of changes have been made: - the transfer len is split into multiple hardware transfers in case its size is bigger than the hardware FIFO size - the FIFO refill is no longer done in the interrupt context, which was a bad idea leading to quick interrupt handler re-entrancy Tested-by: Tanguy Bouzeloc <tanguy.bouzeloc@efixo.com> Signed-off-by: Florian Fainelli <florian@openwrt.org> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
2012-03-09spi: add Broadcom BCM63xx SPI controller driverFlorian Fainelli
This patch adds support for the SPI controller found on the Broadcom BCM63xx SoCs. Signed-off-by: Tanguy Bouzeloc <tanguy.bouzeloc@efixo.com> Signed-off-by: Florian Fainelli <florian@openwrt.org> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>