aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/networking/device_drivers/ethernet/intel
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/networking/device_drivers/ethernet/intel')
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/e100.rst188
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/e1000.rst463
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/e1000e.rst383
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/fm10k.rst142
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/i40e.rst771
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/iavf.rst331
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/ice.rst46
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/igb.rst213
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/igbvf.rst65
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/ixgb.rst468
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/ixgbe.rst541
-rw-r--r--Documentation/networking/device_drivers/ethernet/intel/ixgbevf.rst67
12 files changed, 3678 insertions, 0 deletions
diff --git a/Documentation/networking/device_drivers/ethernet/intel/e100.rst b/Documentation/networking/device_drivers/ethernet/intel/e100.rst
new file mode 100644
index 000000000000..3d4a9ba21946
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/e100.rst
@@ -0,0 +1,188 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=============================================================
+Linux Base Driver for the Intel(R) PRO/100 Family of Adapters
+=============================================================
+
+June 1, 2018
+
+Contents
+========
+
+- In This Release
+- Identifying Your Adapter
+- Building and Installation
+- Driver Configuration Parameters
+- Additional Configurations
+- Known Issues
+- Support
+
+
+In This Release
+===============
+
+This file describes the Linux Base Driver for the Intel(R) PRO/100 Family of
+Adapters. This driver includes support for Itanium(R)2-based systems.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your Intel PRO/100 adapter.
+
+The following features are now available in supported kernels:
+ - Native VLANs
+ - Channel Bonding (teaming)
+ - SNMP
+
+Channel Bonding documentation can be found in the Linux kernel source:
+/Documentation/networking/bonding.rst
+
+
+Identifying Your Adapter
+========================
+
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+Driver Configuration Parameters
+===============================
+
+The default value for each parameter is generally the recommended setting,
+unless otherwise noted.
+
+Rx Descriptors:
+ Number of receive descriptors. A receive descriptor is a data
+ structure that describes a receive buffer and its attributes to the network
+ controller. The data in the descriptor is used by the controller to write
+ data from the controller to host memory. In the 3.x.x driver the valid range
+ for this parameter is 64-256. The default value is 256. This parameter can be
+ changed using the command::
+
+ ethtool -G eth? rx n
+
+ Where n is the number of desired Rx descriptors.
+
+Tx Descriptors:
+ Number of transmit descriptors. A transmit descriptor is a data
+ structure that describes a transmit buffer and its attributes to the network
+ controller. The data in the descriptor is used by the controller to read
+ data from the host memory to the controller. In the 3.x.x driver the valid
+ range for this parameter is 64-256. The default value is 128. This parameter
+ can be changed using the command::
+
+ ethtool -G eth? tx n
+
+ Where n is the number of desired Tx descriptors.
+
+Speed/Duplex:
+ The driver auto-negotiates the link speed and duplex settings by
+ default. The ethtool utility can be used as follows to force speed/duplex.::
+
+ ethtool -s eth? autoneg off speed {10|100} duplex {full|half}
+
+ NOTE: setting the speed/duplex to incorrect values will cause the link to
+ fail.
+
+Event Log Message Level:
+ The driver uses the message level flag to log events
+ to syslog. The message level can be set at driver load time. It can also be
+ set using the command::
+
+ ethtool -s eth? msglvl n
+
+
+Additional Configurations
+=========================
+
+Configuring the Driver on Different Distributions
+-------------------------------------------------
+
+Configuring a network driver to load properly when the system is started
+is distribution dependent. Typically, the configuration process involves
+adding an alias line to `/etc/modprobe.d/*.conf` as well as editing other
+system startup scripts and/or configuration files. Many popular Linux
+distributions ship with tools to make these changes for you. To learn
+the proper way to configure a network device for your system, refer to
+your distribution documentation. If during this process you are asked
+for the driver or module name, the name for the Linux Base Driver for
+the Intel PRO/100 Family of Adapters is e100.
+
+As an example, if you install the e100 driver for two PRO/100 adapters
+(eth0 and eth1), add the following to a configuration file in
+/etc/modprobe.d/::
+
+ alias eth0 e100
+ alias eth1 e100
+
+Viewing Link Messages
+---------------------
+
+In order to see link messages and other Intel driver information on your
+console, you must set the dmesg level up to six. This can be done by
+entering the following on the command line before loading the e100
+driver::
+
+ dmesg -n 6
+
+If you wish to see all messages issued by the driver, including debug
+messages, set the dmesg level to eight.
+
+NOTE: This setting is not saved across reboots.
+
+ethtool
+-------
+
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The ethtool
+version 1.6 or later is required for this functionality.
+
+The latest release of ethtool can be found from
+https://www.kernel.org/pub/software/network/ethtool/
+
+Enabling Wake on LAN (WoL)
+--------------------------
+WoL is provided through the ethtool utility. For instructions on
+enabling WoL with ethtool, refer to the ethtool man page. WoL will be
+enabled on the system during the next shut down or reboot. For this
+driver version, in order to enable WoL, the e100 driver must be loaded
+when shutting down or rebooting the system.
+
+NAPI
+----
+
+NAPI (Rx polling mode) is supported in the e100 driver.
+
+See https://wiki.linuxfoundation.org/networking/napi for more
+information on NAPI.
+
+Multiple Interfaces on Same Ethernet Broadcast Network
+------------------------------------------------------
+
+Due to the default ARP behavior on Linux, it is not possible to have one
+system on two IP networks in the same Ethernet broadcast domain
+(non-partitioned switch) behave as expected. All Ethernet interfaces
+will respond to IP traffic for any IP address assigned to the system.
+This results in unbalanced receive traffic.
+
+If you have multiple interfaces in a server, either turn on ARP
+filtering by
+
+(1) entering::
+
+ echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
+
+ (this only works if your kernel's version is higher than 2.4.5), or
+
+(2) installing the interfaces in separate broadcast domains (either
+ in different switches or in a switch partitioned to VLANs).
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+http://sourceforge.net/projects/e1000
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/e1000.rst b/Documentation/networking/device_drivers/ethernet/intel/e1000.rst
new file mode 100644
index 000000000000..4aaae0f7d6ba
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/e1000.rst
@@ -0,0 +1,463 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+==========================================================
+Linux Base Driver for Intel(R) Ethernet Network Connection
+==========================================================
+
+Intel Gigabit Linux driver.
+Copyright(c) 1999 - 2013 Intel Corporation.
+
+Contents
+========
+
+- Identifying Your Adapter
+- Command Line Parameters
+- Speed and Duplex Configuration
+- Additional Configurations
+- Support
+
+Identifying Your Adapter
+========================
+
+For more information on how to identify your adapter, go to the Adapter &
+Driver ID Guide at:
+
+ http://support.intel.com/support/go/network/adapter/idguide.htm
+
+For the latest Intel network drivers for Linux, refer to the following
+website. In the search field, enter your adapter name or type, or use the
+networking link on the left to search for your adapter:
+
+ http://support.intel.com/support/go/network/adapter/home.htm
+
+Command Line Parameters
+=======================
+
+The default value for each parameter is generally the recommended setting,
+unless otherwise noted.
+
+NOTES:
+ For more information about the AutoNeg, Duplex, and Speed
+ parameters, see the "Speed and Duplex Configuration" section in
+ this document.
+
+ For more information about the InterruptThrottleRate,
+ RxIntDelay, TxIntDelay, RxAbsIntDelay, and TxAbsIntDelay
+ parameters, see the application note at:
+ http://www.intel.com/design/network/applnots/ap450.htm
+
+AutoNeg
+-------
+
+(Supported only on adapters with copper connections)
+
+:Valid Range: 0x01-0x0F, 0x20-0x2F
+:Default Value: 0x2F
+
+This parameter is a bit-mask that specifies the speed and duplex settings
+advertised by the adapter. When this parameter is used, the Speed and
+Duplex parameters must not be specified.
+
+NOTE:
+ Refer to the Speed and Duplex section of this readme for more
+ information on the AutoNeg parameter.
+
+Duplex
+------
+
+(Supported only on adapters with copper connections)
+
+:Valid Range: 0-2 (0=auto-negotiate, 1=half, 2=full)
+:Default Value: 0
+
+This defines the direction in which data is allowed to flow. Can be
+either one or two-directional. If both Duplex and the link partner are
+set to auto-negotiate, the board auto-detects the correct duplex. If the
+link partner is forced (either full or half), Duplex defaults to half-
+duplex.
+
+FlowControl
+-----------
+
+:Valid Range: 0-3 (0=none, 1=Rx only, 2=Tx only, 3=Rx&Tx)
+:Default Value: Reads flow control settings from the EEPROM
+
+This parameter controls the automatic generation(Tx) and response(Rx)
+to Ethernet PAUSE frames.
+
+InterruptThrottleRate
+---------------------
+
+(not supported on Intel(R) 82542, 82543 or 82544-based adapters)
+
+:Valid Range:
+ 0,1,3,4,100-100000 (0=off, 1=dynamic, 3=dynamic conservative,
+ 4=simplified balancing)
+:Default Value: 3
+
+The driver can limit the amount of interrupts per second that the adapter
+will generate for incoming packets. It does this by writing a value to the
+adapter that is based on the maximum amount of interrupts that the adapter
+will generate per second.
+
+Setting InterruptThrottleRate to a value greater or equal to 100
+will program the adapter to send out a maximum of that many interrupts
+per second, even if more packets have come in. This reduces interrupt
+load on the system and can lower CPU utilization under heavy load,
+but will increase latency as packets are not processed as quickly.
+
+The default behaviour of the driver previously assumed a static
+InterruptThrottleRate value of 8000, providing a good fallback value for
+all traffic types,but lacking in small packet performance and latency.
+The hardware can handle many more small packets per second however, and
+for this reason an adaptive interrupt moderation algorithm was implemented.
+
+Since 7.3.x, the driver has two adaptive modes (setting 1 or 3) in which
+it dynamically adjusts the InterruptThrottleRate value based on the traffic
+that it receives. After determining the type of incoming traffic in the last
+timeframe, it will adjust the InterruptThrottleRate to an appropriate value
+for that traffic.
+
+The algorithm classifies the incoming traffic every interval into
+classes. Once the class is determined, the InterruptThrottleRate value is
+adjusted to suit that traffic type the best. There are three classes defined:
+"Bulk traffic", for large amounts of packets of normal size; "Low latency",
+for small amounts of traffic and/or a significant percentage of small
+packets; and "Lowest latency", for almost completely small packets or
+minimal traffic.
+
+In dynamic conservative mode, the InterruptThrottleRate value is set to 4000
+for traffic that falls in class "Bulk traffic". If traffic falls in the "Low
+latency" or "Lowest latency" class, the InterruptThrottleRate is increased
+stepwise to 20000. This default mode is suitable for most applications.
+
+For situations where low latency is vital such as cluster or
+grid computing, the algorithm can reduce latency even more when
+InterruptThrottleRate is set to mode 1. In this mode, which operates
+the same as mode 3, the InterruptThrottleRate will be increased stepwise to
+70000 for traffic in class "Lowest latency".
+
+In simplified mode the interrupt rate is based on the ratio of TX and
+RX traffic. If the bytes per second rate is approximately equal, the
+interrupt rate will drop as low as 2000 interrupts per second. If the
+traffic is mostly transmit or mostly receive, the interrupt rate could
+be as high as 8000.
+
+Setting InterruptThrottleRate to 0 turns off any interrupt moderation
+and may improve small packet latency, but is generally not suitable
+for bulk throughput traffic.
+
+NOTE:
+ InterruptThrottleRate takes precedence over the TxAbsIntDelay and
+ RxAbsIntDelay parameters. In other words, minimizing the receive
+ and/or transmit absolute delays does not force the controller to
+ generate more interrupts than what the Interrupt Throttle Rate
+ allows.
+
+CAUTION:
+ If you are using the Intel(R) PRO/1000 CT Network Connection
+ (controller 82547), setting InterruptThrottleRate to a value
+ greater than 75,000, may hang (stop transmitting) adapters
+ under certain network conditions. If this occurs a NETDEV
+ WATCHDOG message is logged in the system event log. In
+ addition, the controller is automatically reset, restoring
+ the network connection. To eliminate the potential for the
+ hang, ensure that InterruptThrottleRate is set no greater
+ than 75,000 and is not set to 0.
+
+NOTE:
+ When e1000 is loaded with default settings and multiple adapters
+ are in use simultaneously, the CPU utilization may increase non-
+ linearly. In order to limit the CPU utilization without impacting
+ the overall throughput, we recommend that you load the driver as
+ follows::
+
+ modprobe e1000 InterruptThrottleRate=3000,3000,3000
+
+ This sets the InterruptThrottleRate to 3000 interrupts/sec for
+ the first, second, and third instances of the driver. The range
+ of 2000 to 3000 interrupts per second works on a majority of
+ systems and is a good starting point, but the optimal value will
+ be platform-specific. If CPU utilization is not a concern, use
+ RX_POLLING (NAPI) and default driver settings.
+
+RxDescriptors
+-------------
+
+:Valid Range:
+ - 48-256 for 82542 and 82543-based adapters
+ - 48-4096 for all other supported adapters
+:Default Value: 256
+
+This value specifies the number of receive buffer descriptors allocated
+by the driver. Increasing this value allows the driver to buffer more
+incoming packets, at the expense of increased system memory utilization.
+
+Each descriptor is 16 bytes. A receive buffer is also allocated for each
+descriptor and can be either 2048, 4096, 8192, or 16384 bytes, depending
+on the MTU setting. The maximum MTU size is 16110.
+
+NOTE:
+ MTU designates the frame size. It only needs to be set for Jumbo
+ Frames. Depending on the available system resources, the request
+ for a higher number of receive descriptors may be denied. In this
+ case, use a lower number.
+
+RxIntDelay
+----------
+
+:Valid Range: 0-65535 (0=off)
+:Default Value: 0
+
+This value delays the generation of receive interrupts in units of 1.024
+microseconds. Receive interrupt reduction can improve CPU efficiency if
+properly tuned for specific network traffic. Increasing this value adds
+extra latency to frame reception and can end up decreasing the throughput
+of TCP traffic. If the system is reporting dropped receives, this value
+may be set too high, causing the driver to run out of available receive
+descriptors.
+
+CAUTION:
+ When setting RxIntDelay to a value other than 0, adapters may
+ hang (stop transmitting) under certain network conditions. If
+ this occurs a NETDEV WATCHDOG message is logged in the system
+ event log. In addition, the controller is automatically reset,
+ restoring the network connection. To eliminate the potential
+ for the hang ensure that RxIntDelay is set to 0.
+
+RxAbsIntDelay
+-------------
+
+(This parameter is supported only on 82540, 82545 and later adapters.)
+
+:Valid Range: 0-65535 (0=off)
+:Default Value: 128
+
+This value, in units of 1.024 microseconds, limits the delay in which a
+receive interrupt is generated. Useful only if RxIntDelay is non-zero,
+this value ensures that an interrupt is generated after the initial
+packet is received within the set amount of time. Proper tuning,
+along with RxIntDelay, may improve traffic throughput in specific network
+conditions.
+
+Speed
+-----
+
+(This parameter is supported only on adapters with copper connections.)
+
+:Valid Settings: 0, 10, 100, 1000
+:Default Value: 0 (auto-negotiate at all supported speeds)
+
+Speed forces the line speed to the specified value in megabits per second
+(Mbps). If this parameter is not specified or is set to 0 and the link
+partner is set to auto-negotiate, the board will auto-detect the correct
+speed. Duplex should also be set when Speed is set to either 10 or 100.
+
+TxDescriptors
+-------------
+
+:Valid Range:
+ - 48-256 for 82542 and 82543-based adapters
+ - 48-4096 for all other supported adapters
+:Default Value: 256
+
+This value is the number of transmit descriptors allocated by the driver.
+Increasing this value allows the driver to queue more transmits. Each
+descriptor is 16 bytes.
+
+NOTE:
+ Depending on the available system resources, the request for a
+ higher number of transmit descriptors may be denied. In this case,
+ use a lower number.
+
+TxIntDelay
+----------
+
+:Valid Range: 0-65535 (0=off)
+:Default Value: 8
+
+This value delays the generation of transmit interrupts in units of
+1.024 microseconds. Transmit interrupt reduction can improve CPU
+efficiency if properly tuned for specific network traffic. If the
+system is reporting dropped transmits, this value may be set too high
+causing the driver to run out of available transmit descriptors.
+
+TxAbsIntDelay
+-------------
+
+(This parameter is supported only on 82540, 82545 and later adapters.)
+
+:Valid Range: 0-65535 (0=off)
+:Default Value: 32
+
+This value, in units of 1.024 microseconds, limits the delay in which a
+transmit interrupt is generated. Useful only if TxIntDelay is non-zero,
+this value ensures that an interrupt is generated after the initial
+packet is sent on the wire within the set amount of time. Proper tuning,
+along with TxIntDelay, may improve traffic throughput in specific
+network conditions.
+
+XsumRX
+------
+
+(This parameter is NOT supported on the 82542-based adapter.)
+
+:Valid Range: 0-1
+:Default Value: 1
+
+A value of '1' indicates that the driver should enable IP checksum
+offload for received packets (both UDP and TCP) to the adapter hardware.
+
+Copybreak
+---------
+
+:Valid Range: 0-xxxxxxx (0=off)
+:Default Value: 256
+:Usage: modprobe e1000.ko copybreak=128
+
+Driver copies all packets below or equaling this size to a fresh RX
+buffer before handing it up the stack.
+
+This parameter is different than other parameters, in that it is a
+single (not 1,1,1 etc.) parameter applied to all driver instances and
+it is also available during runtime at
+/sys/module/e1000/parameters/copybreak
+
+SmartPowerDownEnable
+--------------------
+
+:Valid Range: 0-1
+:Default Value: 0 (disabled)
+
+Allows PHY to turn off in lower power states. The user can turn off
+this parameter in supported chipsets.
+
+Speed and Duplex Configuration
+==============================
+
+Three keywords are used to control the speed and duplex configuration.
+These keywords are Speed, Duplex, and AutoNeg.
+
+If the board uses a fiber interface, these keywords are ignored, and the
+fiber interface board only links at 1000 Mbps full-duplex.
+
+For copper-based boards, the keywords interact as follows:
+
+- The default operation is auto-negotiate. The board advertises all
+ supported speed and duplex combinations, and it links at the highest
+ common speed and duplex mode IF the link partner is set to auto-negotiate.
+
+- If Speed = 1000, limited auto-negotiation is enabled and only 1000 Mbps
+ is advertised (The 1000BaseT spec requires auto-negotiation.)
+
+- If Speed = 10 or 100, then both Speed and Duplex should be set. Auto-
+ negotiation is disabled, and the AutoNeg parameter is ignored. Partner
+ SHOULD also be forced.
+
+The AutoNeg parameter is used when more control is required over the
+auto-negotiation process. It should be used when you wish to control which
+speed and duplex combinations are advertised during the auto-negotiation
+process.
+
+The parameter may be specified as either a decimal or hexadecimal value as
+determined by the bitmap below.
+
+============== ====== ====== ======= ======= ====== ====== ======= ======
+Bit position 7 6 5 4 3 2 1 0
+Decimal Value 128 64 32 16 8 4 2 1
+Hex value 80 40 20 10 8 4 2 1
+Speed (Mbps) N/A N/A 1000 N/A 100 100 10 10
+Duplex Full Full Half Full Half
+============== ====== ====== ======= ======= ====== ====== ======= ======
+
+Some examples of using AutoNeg::
+
+ modprobe e1000 AutoNeg=0x01 (Restricts autonegotiation to 10 Half)
+ modprobe e1000 AutoNeg=1 (Same as above)
+ modprobe e1000 AutoNeg=0x02 (Restricts autonegotiation to 10 Full)
+ modprobe e1000 AutoNeg=0x03 (Restricts autonegotiation to 10 Half or 10 Full)
+ modprobe e1000 AutoNeg=0x04 (Restricts autonegotiation to 100 Half)
+ modprobe e1000 AutoNeg=0x05 (Restricts autonegotiation to 10 Half or 100
+ Half)
+ modprobe e1000 AutoNeg=0x020 (Restricts autonegotiation to 1000 Full)
+ modprobe e1000 AutoNeg=32 (Same as above)
+
+Note that when this parameter is used, Speed and Duplex must not be specified.
+
+If the link partner is forced to a specific speed and duplex, then this
+parameter should not be used. Instead, use the Speed and Duplex parameters
+previously mentioned to force the adapter to the same speed and duplex.
+
+Additional Configurations
+=========================
+
+Jumbo Frames
+------------
+
+ Jumbo Frames support is enabled by changing the MTU to a value larger than
+ the default of 1500. Use the ifconfig command to increase the MTU size.
+ For example::
+
+ ifconfig eth<x> mtu 9000 up
+
+ This setting is not saved across reboots. It can be made permanent if
+ you add::
+
+ MTU=9000
+
+ to the file /etc/sysconfig/network-scripts/ifcfg-eth<x>. This example
+ applies to the Red Hat distributions; other distributions may store this
+ setting in a different location.
+
+Notes:
+ Degradation in throughput performance may be observed in some Jumbo frames
+ environments. If this is observed, increasing the application's socket buffer
+ size and/or increasing the /proc/sys/net/ipv4/tcp_*mem entry values may help.
+ See the specific application manual and /usr/src/linux*/Documentation/
+ networking/ip-sysctl.txt for more details.
+
+ - The maximum MTU setting for Jumbo Frames is 16110. This value coincides
+ with the maximum Jumbo Frames size of 16128.
+
+ - Using Jumbo frames at 10 or 100 Mbps is not supported and may result in
+ poor performance or loss of link.
+
+ - Adapters based on the Intel(R) 82542 and 82573V/E controller do not
+ support Jumbo Frames. These correspond to the following product names::
+
+ Intel(R) PRO/1000 Gigabit Server Adapter
+ Intel(R) PRO/1000 PM Network Connection
+
+ethtool
+-------
+
+ The driver utilizes the ethtool interface for driver configuration and
+ diagnostics, as well as displaying statistical information. The ethtool
+ version 1.6 or later is required for this functionality.
+
+ The latest release of ethtool can be found from
+ https://www.kernel.org/pub/software/network/ethtool/
+
+Enabling Wake on LAN (WoL)
+--------------------------
+
+ WoL is configured through the ethtool utility.
+
+ WoL will be enabled on the system during the next shut down or reboot.
+ For this driver version, in order to enable WoL, the e1000 driver must be
+ loaded when shutting down or rebooting the system.
+
+Support
+=======
+
+For general information, go to the Intel support website at:
+
+ http://support.intel.com
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+ http://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on the supported
+kernel with a supported adapter, email the specific information related
+to the issue to e1000-devel@lists.sf.net
diff --git a/Documentation/networking/device_drivers/ethernet/intel/e1000e.rst b/Documentation/networking/device_drivers/ethernet/intel/e1000e.rst
new file mode 100644
index 000000000000..f49cd370e7bf
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/e1000e.rst
@@ -0,0 +1,383 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=====================================================
+Linux Driver for Intel(R) Ethernet Network Connection
+=====================================================
+
+Intel Gigabit Linux driver.
+Copyright(c) 2008-2018 Intel Corporation.
+
+Contents
+========
+
+- Identifying Your Adapter
+- Command Line Parameters
+- Additional Configurations
+- Support
+
+
+Identifying Your Adapter
+========================
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+
+Command Line Parameters
+=======================
+If the driver is built as a module, the following optional parameters are used
+by entering them on the command line with the modprobe command using this
+syntax::
+
+ modprobe e1000e [<option>=<VAL1>,<VAL2>,...]
+
+There needs to be a <VAL#> for each network port in the system supported by
+this driver. The values will be applied to each instance, in function order.
+For example::
+
+ modprobe e1000e InterruptThrottleRate=16000,16000
+
+In this case, there are two network ports supported by e1000e in the system.
+The default value for each parameter is generally the recommended setting,
+unless otherwise noted.
+
+NOTE: A descriptor describes a data buffer and attributes related to the data
+buffer. This information is accessed by the hardware.
+
+InterruptThrottleRate
+---------------------
+:Valid Range: 0,1,3,4,100-100000
+:Default Value: 3
+
+Interrupt Throttle Rate controls the number of interrupts each interrupt
+vector can generate per second. Increasing ITR lowers latency at the cost of
+increased CPU utilization, though it may help throughput in some circumstances.
+
+Setting InterruptThrottleRate to a value greater or equal to 100
+will program the adapter to send out a maximum of that many interrupts
+per second, even if more packets have come in. This reduces interrupt
+load on the system and can lower CPU utilization under heavy load,
+but will increase latency as packets are not processed as quickly.
+
+The default behaviour of the driver previously assumed a static
+InterruptThrottleRate value of 8000, providing a good fallback value for
+all traffic types, but lacking in small packet performance and latency.
+The hardware can handle many more small packets per second however, and
+for this reason an adaptive interrupt moderation algorithm was implemented.
+
+The driver has two adaptive modes (setting 1 or 3) in which
+it dynamically adjusts the InterruptThrottleRate value based on the traffic
+that it receives. After determining the type of incoming traffic in the last
+timeframe, it will adjust the InterruptThrottleRate to an appropriate value
+for that traffic.
+
+The algorithm classifies the incoming traffic every interval into
+classes. Once the class is determined, the InterruptThrottleRate value is
+adjusted to suit that traffic type the best. There are three classes defined:
+"Bulk traffic", for large amounts of packets of normal size; "Low latency",
+for small amounts of traffic and/or a significant percentage of small
+packets; and "Lowest latency", for almost completely small packets or
+minimal traffic.
+
+ - 0: Off
+ Turns off any interrupt moderation and may improve small packet latency.
+ However, this is generally not suitable for bulk throughput traffic due
+ to the increased CPU utilization of the higher interrupt rate.
+ - 1: Dynamic mode
+ This mode attempts to moderate interrupts per vector while maintaining
+ very low latency. This can sometimes cause extra CPU utilization. If
+ planning on deploying e1000e in a latency sensitive environment, this
+ parameter should be considered.
+ - 3: Dynamic Conservative mode (default)
+ In dynamic conservative mode, the InterruptThrottleRate value is set to
+ 4000 for traffic that falls in class "Bulk traffic". If traffic falls in
+ the "Low latency" or "Lowest latency" class, the InterruptThrottleRate is
+ increased stepwise to 20000. This default mode is suitable for most
+ applications.
+ - 4: Simplified Balancing mode
+ In simplified mode the interrupt rate is based on the ratio of TX and
+ RX traffic. If the bytes per second rate is approximately equal, the
+ interrupt rate will drop as low as 2000 interrupts per second. If the
+ traffic is mostly transmit or mostly receive, the interrupt rate could
+ be as high as 8000.
+ - 100-100000:
+ Setting InterruptThrottleRate to a value greater or equal to 100
+ will program the adapter to send at most that many interrupts per second,
+ even if more packets have come in. This reduces interrupt load on the
+ system and can lower CPU utilization under heavy load, but will increase
+ latency as packets are not processed as quickly.
+
+NOTE: InterruptThrottleRate takes precedence over the TxAbsIntDelay and
+RxAbsIntDelay parameters. In other words, minimizing the receive and/or
+transmit absolute delays does not force the controller to generate more
+interrupts than what the Interrupt Throttle Rate allows.
+
+RxIntDelay
+----------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 0
+
+This value delays the generation of receive interrupts in units of 1.024
+microseconds. Receive interrupt reduction can improve CPU efficiency if
+properly tuned for specific network traffic. Increasing this value adds extra
+latency to frame reception and can end up decreasing the throughput of TCP
+traffic. If the system is reporting dropped receives, this value may be set
+too high, causing the driver to run out of available receive descriptors.
+
+CAUTION: When setting RxIntDelay to a value other than 0, adapters may hang
+(stop transmitting) under certain network conditions. If this occurs a NETDEV
+WATCHDOG message is logged in the system event log. In addition, the
+controller is automatically reset, restoring the network connection. To
+eliminate the potential for the hang ensure that RxIntDelay is set to 0.
+
+RxAbsIntDelay
+-------------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 8
+
+This value, in units of 1.024 microseconds, limits the delay in which a
+receive interrupt is generated. This value ensures that an interrupt is
+generated after the initial packet is received within the set amount of time,
+which is useful only if RxIntDelay is non-zero. Proper tuning, along with
+RxIntDelay, may improve traffic throughput in specific network conditions.
+
+TxIntDelay
+----------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 8
+
+This value delays the generation of transmit interrupts in units of 1.024
+microseconds. Transmit interrupt reduction can improve CPU efficiency if
+properly tuned for specific network traffic. If the system is reporting
+dropped transmits, this value may be set too high causing the driver to run
+out of available transmit descriptors.
+
+TxAbsIntDelay
+-------------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 32
+
+This value, in units of 1.024 microseconds, limits the delay in which a
+transmit interrupt is generated. It is useful only if TxIntDelay is non-zero.
+It ensures that an interrupt is generated after the initial Packet is sent on
+the wire within the set amount of time. Proper tuning, along with TxIntDelay,
+may improve traffic throughput in specific network conditions.
+
+copybreak
+---------
+:Valid Range: 0-xxxxxxx (0=off)
+:Default Value: 256
+
+The driver copies all packets below or equaling this size to a fresh receive
+buffer before handing it up the stack.
+This parameter differs from other parameters because it is a single (not 1,1,1
+etc.) parameter applied to all driver instances and it is also available
+during runtime at /sys/module/e1000e/parameters/copybreak.
+
+To use copybreak, type::
+
+ modprobe e1000e.ko copybreak=128
+
+SmartPowerDownEnable
+--------------------
+:Valid Range: 0,1
+:Default Value: 0 (disabled)
+
+Allows the PHY to turn off in lower power states. The user can turn off this
+parameter in supported chipsets.
+
+KumeranLockLoss
+---------------
+:Valid Range: 0,1
+:Default Value: 1 (enabled)
+
+This workaround skips resetting the PHY at shutdown for the initial silicon
+releases of ICH8 systems.
+
+IntMode
+-------
+:Valid Range: 0-2
+:Default Value: 0
+
+ +-------+----------------+
+ | Value | Interrupt Mode |
+ +=======+================+
+ | 0 | Legacy |
+ +-------+----------------+
+ | 1 | MSI |
+ +-------+----------------+
+ | 2 | MSI-X |
+ +-------+----------------+
+
+IntMode allows load time control over the type of interrupt registered for by
+the driver. MSI-X is required for multiple queue support, and some kernels and
+combinations of kernel .config options will force a lower level of interrupt
+support.
+
+This command will show different values for each type of interrupt::
+
+ cat /proc/interrupts
+
+CrcStripping
+------------
+:Valid Range: 0,1
+:Default Value: 1 (enabled)
+
+Strip the CRC from received packets before sending up the network stack. If
+you have a machine with a BMC enabled but cannot receive IPMI traffic after
+loading or enabling the driver, try disabling this feature.
+
+WriteProtectNVM
+---------------
+:Valid Range: 0,1
+:Default Value: 1 (enabled)
+
+If set to 1, configure the hardware to ignore all write/erase cycles to the
+GbE region in the ICHx NVM (in order to prevent accidental corruption of the
+NVM). This feature can be disabled by setting the parameter to 0 during initial
+driver load.
+
+NOTE: The machine must be power cycled (full off/on) when enabling NVM writes
+via setting the parameter to zero. Once the NVM has been locked (via the
+parameter at 1 when the driver loads) it cannot be unlocked except via power
+cycle.
+
+Debug
+-----
+:Valid Range: 0-16 (0=none,...,16=all)
+:Default Value: 0
+
+This parameter adjusts the level of debug messages displayed in the system logs.
+
+
+Additional Features and Configurations
+======================================
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file:
+
+- For RHEL: /etc/sysconfig/network-scripts/ifcfg-eth<x>
+- For SLES: /etc/sysconfig/network/<config_file>
+
+NOTE: The maximum MTU setting for Jumbo Frames is 8996. This value coincides
+with the maximum Jumbo Frames size of 9018 bytes.
+
+NOTE: Using Jumbo frames at 10 or 100 Mbps is not supported and may result in
+poor performance or loss of link.
+
+NOTE: The following adapters limit Jumbo Frames sized packets to a maximum of
+4088 bytes:
+
+ - Intel(R) 82578DM Gigabit Network Connection
+ - Intel(R) 82577LM Gigabit Network Connection
+
+The following adapters do not support Jumbo Frames:
+
+ - Intel(R) PRO/1000 Gigabit Server Adapter
+ - Intel(R) PRO/1000 PM Network Connection
+ - Intel(R) 82562G 10/100 Network Connection
+ - Intel(R) 82562G-2 10/100 Network Connection
+ - Intel(R) 82562GT 10/100 Network Connection
+ - Intel(R) 82562GT-2 10/100 Network Connection
+ - Intel(R) 82562V 10/100 Network Connection
+ - Intel(R) 82562V-2 10/100 Network Connection
+ - Intel(R) 82566DC Gigabit Network Connection
+ - Intel(R) 82566DC-2 Gigabit Network Connection
+ - Intel(R) 82566DM Gigabit Network Connection
+ - Intel(R) 82566MC Gigabit Network Connection
+ - Intel(R) 82566MM Gigabit Network Connection
+ - Intel(R) 82567V-3 Gigabit Network Connection
+ - Intel(R) 82577LC Gigabit Network Connection
+ - Intel(R) 82578DC Gigabit Network Connection
+
+NOTE: Jumbo Frames cannot be configured on an 82579-based Network device if
+MACSec is enabled on the system.
+
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+
+https://www.kernel.org/pub/software/network/ethtool/
+
+NOTE: When validating enable/disable tests on some parts (for example, 82578),
+it is necessary to add a few seconds between tests when working with ethtool.
+
+
+Speed and Duplex Configuration
+------------------------------
+In addressing speed and duplex configuration issues, you need to distinguish
+between copper-based adapters and fiber-based adapters.
+
+In the default mode, an Intel(R) Ethernet Network Adapter using copper
+connections will attempt to auto-negotiate with its link partner to determine
+the best setting. If the adapter cannot establish link with the link partner
+using auto-negotiation, you may need to manually configure the adapter and link
+partner to identical settings to establish link and pass packets. This should
+only be needed when attempting to link with an older switch that does not
+support auto-negotiation or one that has been forced to a specific speed or
+duplex mode. Your link partner must match the setting you choose. 1 Gbps speeds
+and higher cannot be forced. Use the autonegotiation advertising setting to
+manually set devices for 1 Gbps and higher.
+
+Speed, duplex, and autonegotiation advertising are configured through the
+ethtool utility.
+
+Caution: Only experienced network administrators should force speed and duplex
+or change autonegotiation advertising manually. The settings at the switch must
+always match the adapter settings. Adapter performance may suffer or your
+adapter may not operate if you configure the adapter differently from your
+switch.
+
+An Intel(R) Ethernet Network Adapter using fiber-based connections, however,
+will not attempt to auto-negotiate with its link partner since those adapters
+operate only in full duplex and only at their native speed.
+
+
+Enabling Wake on LAN (WoL)
+--------------------------
+WoL is configured through the ethtool utility.
+
+WoL will be enabled on the system during the next shut down or reboot. For
+this driver version, in order to enable WoL, the e1000e driver must be loaded
+prior to shutting down or suspending the system.
+
+NOTE: Wake on LAN is only supported on port A for the following devices:
+- Intel(R) PRO/1000 PT Dual Port Network Connection
+- Intel(R) PRO/1000 PT Dual Port Server Connection
+- Intel(R) PRO/1000 PT Dual Port Server Adapter
+- Intel(R) PRO/1000 PF Dual Port Server Adapter
+- Intel(R) PRO/1000 PT Quad Port Server Adapter
+- Intel(R) Gigabit PT Quad Port Server ExpressModule
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/fm10k.rst b/Documentation/networking/device_drivers/ethernet/intel/fm10k.rst
new file mode 100644
index 000000000000..9258ef6f515c
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/fm10k.rst
@@ -0,0 +1,142 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=============================================================
+Linux Base Driver for Intel(R) Ethernet Multi-host Controller
+=============================================================
+
+August 20, 2018
+Copyright(c) 2015-2018 Intel Corporation.
+
+Contents
+========
+- Identifying Your Adapter
+- Additional Configurations
+- Performance Tuning
+- Known Issues
+- Support
+
+Identifying Your Adapter
+========================
+The driver in this release is compatible with devices based on the Intel(R)
+Ethernet Multi-host Controller.
+
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+
+Flow Control
+------------
+The Intel(R) Ethernet Switch Host Interface Driver does not support Flow
+Control. It will not send pause frames. This may result in dropped frames.
+
+
+Virtual Functions (VFs)
+-----------------------
+Use sysfs to enable VFs.
+Valid Range: 0-64
+
+For example::
+
+ echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs //enable VFs
+ echo 0 > /sys/class/net/$dev/device/sriov_numvfs //disable VFs
+
+NOTE: Neither the device nor the driver control how VFs are mapped into config
+space. Bus layout will vary by operating system. On operating systems that
+support it, you can check sysfs to find the mapping.
+
+NOTE: When SR-IOV mode is enabled, hardware VLAN filtering and VLAN tag
+stripping/insertion will remain enabled. Please remove the old VLAN filter
+before the new VLAN filter is added. For example::
+
+ ip link set eth0 vf 0 vlan 100 // set vlan 100 for VF 0
+ ip link set eth0 vf 0 vlan 0 // Delete vlan 100
+ ip link set eth0 vf 0 vlan 200 // set a new vlan 200 for VF 0
+
+
+Additional Features and Configurations
+======================================
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file:
+
+- For RHEL: /etc/sysconfig/network-scripts/ifcfg-eth<x>
+- For SLES: /etc/sysconfig/network/<config_file>
+
+NOTE: The maximum MTU setting for Jumbo Frames is 15342. This value coincides
+with the maximum Jumbo Frames size of 15364 bytes.
+
+NOTE: This driver will attempt to use multiple page sized buffers to receive
+each jumbo packet. This should help to avoid buffer starvation issues when
+allocating receive packets.
+
+
+Generic Receive Offload, aka GRO
+--------------------------------
+The driver supports the in-kernel software implementation of GRO. GRO has
+shown that by coalescing Rx traffic into larger chunks of data, CPU
+utilization can be significantly reduced when under large Rx load. GRO is an
+evolution of the previously-used LRO interface. GRO is able to coalesce
+other protocols besides TCP. It's also safe to use with configurations that
+are problematic for LRO, namely bridging and iSCSI.
+
+
+
+Supported ethtool Commands and Options for Filtering
+----------------------------------------------------
+-n --show-nfc
+ Retrieves the receive network flow classification configurations.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6
+ Retrieves the hash options for the specified network traffic type.
+
+-N --config-nfc
+ Configures the receive network flow classification.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6 m|v|t|s|d|f|n|r
+ Configures the hash options for the specified network traffic type.
+
+- udp4: UDP over IPv4
+- udp6: UDP over IPv6
+- f Hash on bytes 0 and 1 of the Layer 4 header of the rx packet.
+- n Hash on bytes 2 and 3 of the Layer 4 header of the rx packet.
+
+
+Known Issues/Troubleshooting
+============================
+
+Enabling SR-IOV in a 64-bit Microsoft Windows Server 2012/R2 guest OS under Linux KVM
+-------------------------------------------------------------------------------------
+KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM. This
+includes traditional PCIe devices, as well as SR-IOV-capable devices based on
+the Intel Ethernet Controller XL710.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/i40e.rst b/Documentation/networking/device_drivers/ethernet/intel/i40e.rst
new file mode 100644
index 000000000000..8a9b18573688
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/i40e.rst
@@ -0,0 +1,771 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=================================================================
+Linux Base Driver for the Intel(R) Ethernet Controller 700 Series
+=================================================================
+
+Intel 40 Gigabit Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+
+- Overview
+- Identifying Your Adapter
+- Intel(R) Ethernet Flow Director
+- Additional Configurations
+- Known Issues
+- Support
+
+
+Driver information can be obtained using ethtool, lspci, and ifconfig.
+Instructions on updating ethtool can be found in the section Additional
+Configurations later in this document.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your Intel adapter. All hardware requirements listed apply to use
+with Linux.
+
+
+Identifying Your Adapter
+========================
+The driver is compatible with devices based on the following:
+
+ * Intel(R) Ethernet Controller X710
+ * Intel(R) Ethernet Controller XL710
+ * Intel(R) Ethernet Network Connection X722
+ * Intel(R) Ethernet Controller XXV710
+
+For the best performance, make sure the latest NVM/FW is installed on your
+device.
+
+For information on how to identify your adapter, and for the latest NVM/FW
+images and Intel network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+SFP+ and QSFP+ Devices
+----------------------
+For information about supported media, refer to this document:
+https://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf
+
+NOTE: Some adapters based on the Intel(R) Ethernet Controller 700 Series only
+support Intel Ethernet Optics modules. On these adapters, other modules are not
+supported and will not function. In all cases Intel recommends using Intel
+Ethernet Optics; other modules may function but are not validated by Intel.
+Contact Intel for supported media types.
+
+NOTE: For connections based on Intel(R) Ethernet Controller 700 Series, support
+is dependent on your system board. Please see your vendor for details.
+
+NOTE: In systems that do not have adequate airflow to cool the adapter and
+optical modules, you must use high temperature optical modules.
+
+Virtual Functions (VFs)
+-----------------------
+Use sysfs to enable VFs. For example::
+
+ #echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs #enable VFs
+ #echo 0 > /sys/class/net/$dev/device/sriov_numvfs #disable VFs
+
+For example, the following instructions will configure PF eth0 and the first VF
+on VLAN 10::
+
+ $ ip link set dev eth0 vf 0 vlan 10
+
+VLAN Tag Packet Steering
+------------------------
+Allows you to send all packets with a specific VLAN tag to a particular SR-IOV
+virtual function (VF). Further, this feature allows you to designate a
+particular VF as trusted, and allows that trusted VF to request selective
+promiscuous mode on the Physical Function (PF).
+
+To set a VF as trusted or untrusted, enter the following command in the
+Hypervisor::
+
+ # ip link set dev eth0 vf 1 trust [on|off]
+
+Once the VF is designated as trusted, use the following commands in the VM to
+set the VF to promiscuous mode.
+
+::
+
+ For promiscuous all:
+ #ip link set eth2 promisc on
+ Where eth2 is a VF interface in the VM
+
+ For promiscuous Multicast:
+ #ip link set eth2 allmulticast on
+ Where eth2 is a VF interface in the VM
+
+NOTE: By default, the ethtool priv-flag vf-true-promisc-support is set to
+"off",meaning that promiscuous mode for the VF will be limited. To set the
+promiscuous mode for the VF to true promiscuous and allow the VF to see all
+ingress traffic, use the following command::
+
+ #ethtool -set-priv-flags p261p1 vf-true-promisc-support on
+
+The vf-true-promisc-support priv-flag does not enable promiscuous mode; rather,
+it designates which type of promiscuous mode (limited or true) you will get
+when you enable promiscuous mode using the ip link commands above. Note that
+this is a global setting that affects the entire device. However,the
+vf-true-promisc-support priv-flag is only exposed to the first PF of the
+device. The PF remains in limited promiscuous mode (unless it is in MFP mode)
+regardless of the vf-true-promisc-support setting.
+
+Now add a VLAN interface on the VF interface::
+
+ #ip link add link eth2 name eth2.100 type vlan id 100
+
+Note that the order in which you set the VF to promiscuous mode and add the
+VLAN interface does not matter (you can do either first). The end result in
+this example is that the VF will get all traffic that is tagged with VLAN 100.
+
+Intel(R) Ethernet Flow Director
+-------------------------------
+The Intel Ethernet Flow Director performs the following tasks:
+
+- Directs receive packets according to their flows to different queues.
+- Enables tight control on routing a flow in the platform.
+- Matches flows and CPU cores for flow affinity.
+- Supports multiple parameters for flexible flow classification and load
+ balancing (in SFP mode only).
+
+NOTE: The Linux i40e driver supports the following flow types: IPv4, TCPv4, and
+UDPv4. For a given flow type, it supports valid combinations of IP addresses
+(source or destination) and UDP/TCP ports (source and destination). For
+example, you can supply only a source IP address, a source IP address and a
+destination port, or any combination of one or more of these four parameters.
+
+NOTE: The Linux i40e driver allows you to filter traffic based on a
+user-defined flexible two-byte pattern and offset by using the ethtool user-def
+and mask fields. Only L3 and L4 flow types are supported for user-defined
+flexible filters. For a given flow type, you must clear all Intel Ethernet Flow
+Director filters before changing the input set (for that flow type).
+
+To enable or disable the Intel Ethernet Flow Director::
+
+ # ethtool -K ethX ntuple <on|off>
+
+When disabling ntuple filters, all the user programmed filters are flushed from
+the driver cache and hardware. All needed filters must be re-added when ntuple
+is re-enabled.
+
+To add a filter that directs packet to queue 2, use -U or -N switch::
+
+ # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
+ 192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1]
+
+To set a filter using only the source and destination IP address::
+
+ # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
+ 192.168.10.2 action 2 [loc 1]
+
+To see the list of filters currently present::
+
+ # ethtool <-u|-n> ethX
+
+Application Targeted Routing (ATR) Perfect Filters
+--------------------------------------------------
+ATR is enabled by default when the kernel is in multiple transmit queue mode.
+An ATR Intel Ethernet Flow Director filter rule is added when a TCP-IP flow
+starts and is deleted when the flow ends. When a TCP-IP Intel Ethernet Flow
+Director rule is added from ethtool (Sideband filter), ATR is turned off by the
+driver. To re-enable ATR, the sideband can be disabled with the ethtool -K
+option. For example::
+
+ ethtool –K [adapter] ntuple [off|on]
+
+If sideband is re-enabled after ATR is re-enabled, ATR remains enabled until a
+TCP-IP flow is added. When all TCP-IP sideband rules are deleted, ATR is
+automatically re-enabled.
+
+Packets that match the ATR rules are counted in fdir_atr_match stats in
+ethtool, which also can be used to verify whether ATR rules still exist.
+
+Sideband Perfect Filters
+------------------------
+Sideband Perfect Filters are used to direct traffic that matches specified
+characteristics. They are enabled through ethtool's ntuple interface. To add a
+new filter use the following command::
+
+ ethtool -U <device> flow-type <type> src-ip <ip> dst-ip <ip> src-port <port> \
+ dst-port <port> action <queue>
+
+Where:
+ <device> - the ethernet device to program
+ <type> - can be ip4, tcp4, udp4, or sctp4
+ <ip> - the ip address to match on
+ <port> - the port number to match on
+ <queue> - the queue to direct traffic towards (-1 discards matching traffic)
+
+Use the following command to display all of the active filters::
+
+ ethtool -u <device>
+
+Use the following command to delete a filter::
+
+ ethtool -U <device> delete <N>
+
+Where <N> is the filter id displayed when printing all the active filters, and
+may also have been specified using "loc <N>" when adding the filter.
+
+The following example matches TCP traffic sent from 192.168.0.1, port 5300,
+directed to 192.168.0.5, port 80, and sends it to queue 7::
+
+ ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5 \
+ src-port 5300 dst-port 80 action 7
+
+For each flow-type, the programmed filters must all have the same matching
+input set. For example, issuing the following two commands is acceptable::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10
+
+Issuing the next two commands, however, is not acceptable, since the first
+specifies src-ip and the second specifies dst-ip::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10
+
+The second command will fail with an error. You may program multiple filters
+with the same fields, using different values, but, on one device, you may not
+program two tcp4 filters with different matching fields.
+
+Matching on a sub-portion of a field is not supported by the i40e driver, thus
+partial mask fields are not supported.
+
+The driver also supports matching user-defined data within the packet payload.
+This flexible data is specified using the "user-def" field of the ethtool
+command in the following way:
+
++----------------------------+--------------------------+
+| 31 28 24 20 16 | 15 12 8 4 0 |
++----------------------------+--------------------------+
+| offset into packet payload | 2 bytes of flexible data |
++----------------------------+--------------------------+
+
+For example,
+
+::
+
+ ... user-def 0x4FFFF ...
+
+tells the filter to look 4 bytes into the payload and match that value against
+0xFFFF. The offset is based on the beginning of the payload, and not the
+beginning of the packet. Thus
+
+::
+
+ flow-type tcp4 ... user-def 0x8BEAF ...
+
+would match TCP/IPv4 packets which have the value 0xBEAF 8 bytes into the
+TCP/IPv4 payload.
+
+Note that ICMP headers are parsed as 4 bytes of header and 4 bytes of payload.
+Thus to match the first byte of the payload, you must actually add 4 bytes to
+the offset. Also note that ip4 filters match both ICMP frames as well as raw
+(unknown) ip4 frames, where the payload will be the L3 payload of the IP4 frame.
+
+The maximum offset is 64. The hardware will only read up to 64 bytes of data
+from the payload. The offset must be even because the flexible data is 2 bytes
+long and must be aligned to byte 0 of the packet payload.
+
+The user-defined flexible offset is also considered part of the input set and
+cannot be programmed separately for multiple filters of the same type. However,
+the flexible data is not part of the input set and multiple filters may use the
+same offset but match against different data.
+
+To create filters that direct traffic to a specific Virtual Function, use the
+"action" parameter. Specify the action as a 64 bit value, where the lower 32
+bits represents the queue number, while the next 8 bits represent which VF.
+Note that 0 is the PF, so the VF identifier is offset by 1. For example::
+
+ ... action 0x800000002 ...
+
+specifies to direct traffic to Virtual Function 7 (8 minus 1) into queue 2 of
+that VF.
+
+Note that these filters will not break internal routing rules, and will not
+route traffic that otherwise would not have been sent to the specified Virtual
+Function.
+
+Setting the link-down-on-close Private Flag
+-------------------------------------------
+When the link-down-on-close private flag is set to "on", the port's link will
+go down when the interface is brought down using the ifconfig ethX down command.
+
+Use ethtool to view and set link-down-on-close, as follows::
+
+ ethtool --show-priv-flags ethX
+ ethtool --set-priv-flags ethX link-down-on-close [on|off]
+
+Viewing Link Messages
+---------------------
+Link messages will not be displayed to the console if the distribution is
+restricting system messages. In order to see network driver link messages on
+your console, set dmesg to eight by entering the following::
+
+ dmesg -n 8
+
+NOTE: This setting is not saved across reboots.
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file::
+
+ /etc/sysconfig/network-scripts/ifcfg-eth<x> // for RHEL
+ /etc/sysconfig/network/<config_file> // for SLES
+
+NOTE: The maximum MTU setting for Jumbo Frames is 9702. This value coincides
+with the maximum Jumbo Frames size of 9728 bytes.
+
+NOTE: This driver will attempt to use multiple page sized buffers to receive
+each jumbo packet. This should help to avoid buffer starvation issues when
+allocating receive packets.
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+https://www.kernel.org/pub/software/network/ethtool/
+
+Supported ethtool Commands and Options for Filtering
+----------------------------------------------------
+-n --show-nfc
+ Retrieves the receive network flow classification configurations.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6
+ Retrieves the hash options for the specified network traffic type.
+
+-N --config-nfc
+ Configures the receive network flow classification.
+
+rx-flow-hash tcp4|udp4|ah4|esp4|sctp4|tcp6|udp6|ah6|esp6|sctp6 m|v|t|s|d|f|n|r...
+ Configures the hash options for the specified network traffic type.
+
+udp4 UDP over IPv4
+udp6 UDP over IPv6
+
+f Hash on bytes 0 and 1 of the Layer 4 header of the Rx packet.
+n Hash on bytes 2 and 3 of the Layer 4 header of the Rx packet.
+
+Speed and Duplex Configuration
+------------------------------
+In addressing speed and duplex configuration issues, you need to distinguish
+between copper-based adapters and fiber-based adapters.
+
+In the default mode, an Intel(R) Ethernet Network Adapter using copper
+connections will attempt to auto-negotiate with its link partner to determine
+the best setting. If the adapter cannot establish link with the link partner
+using auto-negotiation, you may need to manually configure the adapter and link
+partner to identical settings to establish link and pass packets. This should
+only be needed when attempting to link with an older switch that does not
+support auto-negotiation or one that has been forced to a specific speed or
+duplex mode. Your link partner must match the setting you choose. 1 Gbps speeds
+and higher cannot be forced. Use the autonegotiation advertising setting to
+manually set devices for 1 Gbps and higher.
+
+NOTE: You cannot set the speed for devices based on the Intel(R) Ethernet
+Network Adapter XXV710 based devices.
+
+Speed, duplex, and autonegotiation advertising are configured through the
+ethtool utility.
+
+Caution: Only experienced network administrators should force speed and duplex
+or change autonegotiation advertising manually. The settings at the switch must
+always match the adapter settings. Adapter performance may suffer or your
+adapter may not operate if you configure the adapter differently from your
+switch.
+
+An Intel(R) Ethernet Network Adapter using fiber-based connections, however,
+will not attempt to auto-negotiate with its link partner since those adapters
+operate only in full duplex and only at their native speed.
+
+NAPI
+----
+NAPI (Rx polling mode) is supported in the i40e driver.
+For more information on NAPI, see
+https://wiki.linuxfoundation.org/networking/napi
+
+Flow Control
+------------
+Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
+receiving and transmitting pause frames for i40e. When transmit is enabled,
+pause frames are generated when the receive packet buffer crosses a predefined
+threshold. When receive is enabled, the transmit unit will halt for the time
+delay specified when a pause frame is received.
+
+NOTE: You must have a flow control capable link partner.
+
+Flow Control is on by default.
+
+Use ethtool to change the flow control settings.
+
+To enable or disable Rx or Tx Flow Control::
+
+ ethtool -A eth? rx <on|off> tx <on|off>
+
+Note: This command only enables or disables Flow Control if auto-negotiation is
+disabled. If auto-negotiation is enabled, this command changes the parameters
+used for auto-negotiation with the link partner.
+
+To enable or disable auto-negotiation::
+
+ ethtool -s eth? autoneg <on|off>
+
+Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending
+on your device, you may not be able to change the auto-negotiation setting.
+
+RSS Hash Flow
+-------------
+Allows you to set the hash bytes per flow type and any combination of one or
+more options for Receive Side Scaling (RSS) hash byte configuration.
+
+::
+
+ # ethtool -N <dev> rx-flow-hash <type> <option>
+
+Where <type> is:
+ tcp4 signifying TCP over IPv4
+ udp4 signifying UDP over IPv4
+ tcp6 signifying TCP over IPv6
+ udp6 signifying UDP over IPv6
+And <option> is one or more of:
+ s Hash on the IP source address of the Rx packet.
+ d Hash on the IP destination address of the Rx packet.
+ f Hash on bytes 0 and 1 of the Layer 4 header of the Rx packet.
+ n Hash on bytes 2 and 3 of the Layer 4 header of the Rx packet.
+
+MAC and VLAN anti-spoofing feature
+----------------------------------
+When a malicious driver attempts to send a spoofed packet, it is dropped by the
+hardware and not transmitted.
+NOTE: This feature can be disabled for a specific Virtual Function (VF)::
+
+ ip link set <pf dev> vf <vf id> spoofchk {off|on}
+
+IEEE 1588 Precision Time Protocol (PTP) Hardware Clock (PHC)
+------------------------------------------------------------
+Precision Time Protocol (PTP) is used to synchronize clocks in a computer
+network. PTP support varies among Intel devices that support this driver. Use
+"ethtool -T <netdev name>" to get a definitive list of PTP capabilities
+supported by the device.
+
+IEEE 802.1ad (QinQ) Support
+---------------------------
+The IEEE 802.1ad standard, informally known as QinQ, allows for multiple VLAN
+IDs within a single Ethernet frame. VLAN IDs are sometimes referred to as
+"tags," and multiple VLAN IDs are thus referred to as a "tag stack." Tag stacks
+allow L2 tunneling and the ability to segregate traffic within a particular
+VLAN ID, among other uses.
+
+The following are examples of how to configure 802.1ad (QinQ)::
+
+ ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
+ ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371
+
+Where "24" and "371" are example VLAN IDs.
+
+NOTES:
+ Receive checksum offloads, cloud filters, and VLAN acceleration are not
+ supported for 802.1ad (QinQ) packets.
+
+VXLAN and GENEVE Overlay HW Offloading
+--------------------------------------
+Virtual Extensible LAN (VXLAN) allows you to extend an L2 network over an L3
+network, which may be useful in a virtualized or cloud environment. Some
+Intel(R) Ethernet Network devices perform VXLAN processing, offloading it from
+the operating system. This reduces CPU utilization.
+
+VXLAN offloading is controlled by the Tx and Rx checksum offload options
+provided by ethtool. That is, if Tx checksum offload is enabled, and the
+adapter has the capability, VXLAN offloading is also enabled.
+
+Support for VXLAN and GENEVE HW offloading is dependent on kernel support of
+the HW offloading features.
+
+Multiple Functions per Port
+---------------------------
+Some adapters based on the Intel Ethernet Controller X710/XL710 support
+multiple functions on a single physical port. Configure these functions through
+the System Setup/BIOS.
+
+Minimum TX Bandwidth is the guaranteed minimum data transmission bandwidth, as
+a percentage of the full physical port link speed, that the partition will
+receive. The bandwidth the partition is awarded will never fall below the level
+you specify.
+
+The range for the minimum bandwidth values is:
+1 to ((100 minus # of partitions on the physical port) plus 1)
+For example, if a physical port has 4 partitions, the range would be:
+1 to ((100 - 4) + 1 = 97)
+
+The Maximum Bandwidth percentage represents the maximum transmit bandwidth
+allocated to the partition as a percentage of the full physical port link
+speed. The accepted range of values is 1-100. The value is used as a limiter,
+should you chose that any one particular function not be able to consume 100%
+of a port's bandwidth (should it be available). The sum of all the values for
+Maximum Bandwidth is not restricted, because no more than 100% of a port's
+bandwidth can ever be used.
+
+NOTE: X710/XXV710 devices fail to enable Max VFs (64) when Multiple Functions
+per Port (MFP) and SR-IOV are enabled. An error from i40e is logged that says
+"add vsi failed for VF N, aq_err 16". To workaround the issue, enable less than
+64 virtual functions (VFs).
+
+Data Center Bridging (DCB)
+--------------------------
+DCB is a configuration Quality of Service implementation in hardware. It uses
+the VLAN priority tag (802.1p) to filter traffic. That means that there are 8
+different priorities that traffic can be filtered into. It also enables
+priority flow control (802.1Qbb) which can limit or eliminate the number of
+dropped packets during network stress. Bandwidth can be allocated to each of
+these priorities, which is enforced at the hardware level (802.1Qaz).
+
+Adapter firmware implements LLDP and DCBX protocol agents as per 802.1AB and
+802.1Qaz respectively. The firmware based DCBX agent runs in willing mode only
+and can accept settings from a DCBX capable peer. Software configuration of
+DCBX parameters via dcbtool/lldptool are not supported.
+
+NOTE: Firmware LLDP can be disabled by setting the private flag disable-fw-lldp.
+
+The i40e driver implements the DCB netlink interface layer to allow user-space
+to communicate with the driver and query DCB configuration for the port.
+
+NOTE:
+The kernel assumes that TC0 is available, and will disable Priority Flow
+Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
+enabled when setting up DCB on your switch.
+
+Interrupt Rate Limiting
+-----------------------
+:Valid Range: 0-235 (0=no limit)
+
+The Intel(R) Ethernet Controller XL710 family supports an interrupt rate
+limiting mechanism. The user can control, via ethtool, the number of
+microseconds between interrupts.
+
+Syntax::
+
+ # ethtool -C ethX rx-usecs-high N
+
+The range of 0-235 microseconds provides an effective range of 4,310 to 250,000
+interrupts per second. The value of rx-usecs-high can be set independently of
+rx-usecs and tx-usecs in the same ethtool command, and is also independent of
+the adaptive interrupt moderation algorithm. The underlying hardware supports
+granularity in 4-microsecond intervals, so adjacent values may result in the
+same interrupt rate.
+
+One possible use case is the following::
+
+ # ethtool -C ethX adaptive-rx off adaptive-tx off rx-usecs-high 20 rx-usecs \
+ 5 tx-usecs 5
+
+The above command would disable adaptive interrupt moderation, and allow a
+maximum of 5 microseconds before indicating a receive or transmit was complete.
+However, instead of resulting in as many as 200,000 interrupts per second, it
+limits total interrupts per second to 50,000 via the rx-usecs-high parameter.
+
+Performance Optimization
+========================
+Driver defaults are meant to fit a wide variety of workloads, but if further
+optimization is required we recommend experimenting with the following settings.
+
+NOTE: For better performance when processing small (64B) frame sizes, try
+enabling Hyper threading in the BIOS in order to increase the number of logical
+cores in the system and subsequently increase the number of queues available to
+the adapter.
+
+Virtualized Environments
+------------------------
+1. Disable XPS on both ends by using the included virt_perf_default script
+or by running the following command as root::
+
+ for file in `ls /sys/class/net/<ethX>/queues/tx-*/xps_cpus`;
+ do echo 0 > $file; done
+
+2. Using the appropriate mechanism (vcpupin) in the vm, pin the cpu's to
+individual lcpu's, making sure to use a set of cpu's included in the
+device's local_cpulist: /sys/class/net/<ethX>/device/local_cpulist.
+
+3. Configure as many Rx/Tx queues in the VM as available. Do not rely on
+the default setting of 1.
+
+
+Non-virtualized Environments
+----------------------------
+Pin the adapter's IRQs to specific cores by disabling the irqbalance service
+and using the included set_irq_affinity script. Please see the script's help
+text for further options.
+
+- The following settings will distribute the IRQs across all the cores evenly::
+
+ # scripts/set_irq_affinity -x all <interface1> , [ <interface2>, ... ]
+
+- The following settings will distribute the IRQs across all the cores that are
+ local to the adapter (same NUMA node)::
+
+ # scripts/set_irq_affinity -x local <interface1> ,[ <interface2>, ... ]
+
+For very CPU intensive workloads, we recommend pinning the IRQs to all cores.
+
+For IP Forwarding: Disable Adaptive ITR and lower Rx and Tx interrupts per
+queue using ethtool.
+
+- Setting rx-usecs and tx-usecs to 125 will limit interrupts to about 8000
+ interrupts per second per queue.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 125 \
+ tx-usecs 125
+
+For lower CPU utilization: Disable Adaptive ITR and lower Rx and Tx interrupts
+per queue using ethtool.
+
+- Setting rx-usecs and tx-usecs to 250 will limit interrupts to about 4000
+ interrupts per second per queue.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 250 \
+ tx-usecs 250
+
+For lower latency: Disable Adaptive ITR and ITR by setting Rx and Tx to 0 using
+ethtool.
+
+::
+
+ # ethtool -C <interface> adaptive-rx off adaptive-tx off rx-usecs 0 \
+ tx-usecs 0
+
+Application Device Queues (ADq)
+-------------------------------
+Application Device Queues (ADq) allows you to dedicate one or more queues to a
+specific application. This can reduce latency for the specified application,
+and allow Tx traffic to be rate limited per application. Follow the steps below
+to set ADq.
+
+1. Create traffic classes (TCs). Maximum of 8 TCs can be created per interface.
+The shaper bw_rlimit parameter is optional.
+
+Example: Sets up two tcs, tc0 and tc1, with 16 queues each and max tx rate set
+to 1Gbit for tc0 and 3Gbit for tc1.
+
+::
+
+ # tc qdisc add dev <interface> root mqprio num_tc 2 map 0 0 0 0 1 1 1 1
+ queues 16@0 16@16 hw 1 mode channel shaper bw_rlimit min_rate 1Gbit 2Gbit
+ max_rate 1Gbit 3Gbit
+
+map: priority mapping for up to 16 priorities to tcs (e.g. map 0 0 0 0 1 1 1 1
+sets priorities 0-3 to use tc0 and 4-7 to use tc1)
+
+queues: for each tc, <num queues>@<offset> (e.g. queues 16@0 16@16 assigns
+16 queues to tc0 at offset 0 and 16 queues to tc1 at offset 16. Max total
+number of queues for all tcs is 64 or number of cores, whichever is lower.)
+
+hw 1 mode channel: ‘channel’ with ‘hw’ set to 1 is a new new hardware
+offload mode in mqprio that makes full use of the mqprio options, the
+TCs, the queue configurations, and the QoS parameters.
+
+shaper bw_rlimit: for each tc, sets minimum and maximum bandwidth rates.
+Totals must be equal or less than port speed.
+
+For example: min_rate 1Gbit 3Gbit: Verify bandwidth limit using network
+monitoring tools such as ifstat or sar –n DEV [interval] [number of samples]
+
+2. Enable HW TC offload on interface::
+
+ # ethtool -K <interface> hw-tc-offload on
+
+3. Apply TCs to ingress (RX) flow of interface::
+
+ # tc qdisc add dev <interface> ingress
+
+NOTES:
+ - Run all tc commands from the iproute2 <pathtoiproute2>/tc/ directory.
+ - ADq is not compatible with cloud filters.
+ - Setting up channels via ethtool (ethtool -L) is not supported when the
+ TCs are configured using mqprio.
+ - You must have iproute2 latest version
+ - NVM version 6.01 or later is required.
+ - ADq cannot be enabled when any the following features are enabled: Data
+ Center Bridging (DCB), Multiple Functions per Port (MFP), or Sideband
+ Filters.
+ - If another driver (for example, DPDK) has set cloud filters, you cannot
+ enable ADq.
+ - Tunnel filters are not supported in ADq. If encapsulated packets do
+ arrive in non-tunnel mode, filtering will be done on the inner headers.
+ For example, for VXLAN traffic in non-tunnel mode, PCTYPE is identified
+ as a VXLAN encapsulated packet, outer headers are ignored. Therefore,
+ inner headers are matched.
+ - If a TC filter on a PF matches traffic over a VF (on the PF), that
+ traffic will be routed to the appropriate queue of the PF, and will
+ not be passed on the VF. Such traffic will end up getting dropped higher
+ up in the TCP/IP stack as it does not match PF address data.
+ - If traffic matches multiple TC filters that point to different TCs,
+ that traffic will be duplicated and sent to all matching TC queues.
+ The hardware switch mirrors the packet to a VSI list when multiple
+ filters are matched.
+
+
+Known Issues/Troubleshooting
+============================
+
+NOTE: 1 Gb devices based on the Intel(R) Ethernet Network Connection X722 do
+not support the following features:
+
+ * Data Center Bridging (DCB)
+ * QOS
+ * VMQ
+ * SR-IOV
+ * Task Encapsulation offload (VXLAN, NVGRE)
+ * Energy Efficient Ethernet (EEE)
+ * Auto-media detect
+
+Unexpected Issues when the device driver and DPDK share a device
+----------------------------------------------------------------
+Unexpected issues may result when an i40e device is in multi driver mode and
+the kernel driver and DPDK driver are sharing the device. This is because
+access to the global NIC resources is not synchronized between multiple
+drivers. Any change to the global NIC configuration (writing to a global
+register, setting global configuration by AQ, or changing switch modes) will
+affect all ports and drivers on the device. Loading DPDK with the
+"multi-driver" module parameter may mitigate some of the issues.
+
+TC0 must be enabled when setting up DCB on a switch
+---------------------------------------------------
+The kernel assumes that TC0 is available, and will disable Priority Flow
+Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
+enabled when setting up DCB on your switch.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/iavf.rst b/Documentation/networking/device_drivers/ethernet/intel/iavf.rst
new file mode 100644
index 000000000000..52e037b11c97
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/iavf.rst
@@ -0,0 +1,331 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=================================================================
+Linux Base Driver for Intel(R) Ethernet Adaptive Virtual Function
+=================================================================
+
+Intel Ethernet Adaptive Virtual Function Linux driver.
+Copyright(c) 2013-2018 Intel Corporation.
+
+Contents
+========
+
+- Overview
+- Identifying Your Adapter
+- Additional Configurations
+- Known Issues/Troubleshooting
+- Support
+
+Overview
+========
+
+This file describes the iavf Linux Base Driver. This driver was formerly
+called i40evf.
+
+The iavf driver supports the below mentioned virtual function devices and
+can only be activated on kernels running the i40e or newer Physical Function
+(PF) driver compiled with CONFIG_PCI_IOV. The iavf driver requires
+CONFIG_PCI_MSI to be enabled.
+
+The guest OS loading the iavf driver must support MSI-X interrupts.
+
+Identifying Your Adapter
+========================
+
+The driver in this kernel is compatible with devices based on the following:
+ * Intel(R) XL710 X710 Virtual Function
+ * Intel(R) X722 Virtual Function
+ * Intel(R) XXV710 Virtual Function
+ * Intel(R) Ethernet Adaptive Virtual Function
+
+For the best performance, make sure the latest NVM/FW is installed on your
+device.
+
+For information on how to identify your adapter, and for the latest NVM/FW
+images and Intel network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+
+Additional Features and Configurations
+======================================
+
+Viewing Link Messages
+---------------------
+Link messages will not be displayed to the console if the distribution is
+restricting system messages. In order to see network driver link messages on
+your console, set dmesg to eight by entering the following::
+
+ # dmesg -n 8
+
+NOTE:
+ This setting is not saved across reboots.
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+https://www.kernel.org/pub/software/network/ethtool/
+
+Setting VLAN Tag Stripping
+--------------------------
+If you have applications that require Virtual Functions (VFs) to receive
+packets with VLAN tags, you can disable VLAN tag stripping for the VF. The
+Physical Function (PF) processes requests issued from the VF to enable or
+disable VLAN tag stripping. Note that if the PF has assigned a VLAN to a VF,
+then requests from that VF to set VLAN tag stripping will be ignored.
+
+To enable/disable VLAN tag stripping for a VF, issue the following command
+from inside the VM in which you are running the VF::
+
+ # ethtool -K <if_name> rxvlan on/off
+
+or alternatively::
+
+ # ethtool --offload <if_name> rxvlan on/off
+
+Adaptive Virtual Function
+-------------------------
+Adaptive Virtual Function (AVF) allows the virtual function driver, or VF, to
+adapt to changing feature sets of the physical function driver (PF) with which
+it is associated. This allows system administrators to update a PF without
+having to update all the VFs associated with it. All AVFs have a single common
+device ID and branding string.
+
+AVFs have a minimum set of features known as "base mode," but may provide
+additional features depending on what features are available in the PF with
+which the AVF is associated. The following are base mode features:
+
+- 4 Queue Pairs (QP) and associated Configuration Status Registers (CSRs)
+ for Tx/Rx
+- i40e descriptors and ring format
+- Descriptor write-back completion
+- 1 control queue, with i40e descriptors, CSRs and ring format
+- 5 MSI-X interrupt vectors and corresponding i40e CSRs
+- 1 Interrupt Throttle Rate (ITR) index
+- 1 Virtual Station Interface (VSI) per VF
+- 1 Traffic Class (TC), TC0
+- Receive Side Scaling (RSS) with 64 entry indirection table and key,
+ configured through the PF
+- 1 unicast MAC address reserved per VF
+- 16 MAC address filters for each VF
+- Stateless offloads - non-tunneled checksums
+- AVF device ID
+- HW mailbox is used for VF to PF communications (including on Windows)
+
+IEEE 802.1ad (QinQ) Support
+---------------------------
+The IEEE 802.1ad standard, informally known as QinQ, allows for multiple VLAN
+IDs within a single Ethernet frame. VLAN IDs are sometimes referred to as
+"tags," and multiple VLAN IDs are thus referred to as a "tag stack." Tag stacks
+allow L2 tunneling and the ability to segregate traffic within a particular
+VLAN ID, among other uses.
+
+The following are examples of how to configure 802.1ad (QinQ)::
+
+ # ip link add link eth0 eth0.24 type vlan proto 802.1ad id 24
+ # ip link add link eth0.24 eth0.24.371 type vlan proto 802.1Q id 371
+
+Where "24" and "371" are example VLAN IDs.
+
+NOTES:
+ Receive checksum offloads, cloud filters, and VLAN acceleration are not
+ supported for 802.1ad (QinQ) packets.
+
+Application Device Queues (ADq)
+-------------------------------
+Application Device Queues (ADq) allows you to dedicate one or more queues to a
+specific application. This can reduce latency for the specified application,
+and allow Tx traffic to be rate limited per application. Follow the steps below
+to set ADq.
+
+Requirements:
+
+- The sch_mqprio, act_mirred and cls_flower modules must be loaded
+- The latest version of iproute2
+- If another driver (for example, DPDK) has set cloud filters, you cannot
+ enable ADQ
+- Depending on the underlying PF device, ADQ cannot be enabled when the
+ following features are enabled:
+
+ + Data Center Bridging (DCB)
+ + Multiple Functions per Port (MFP)
+ + Sideband Filters
+
+1. Create traffic classes (TCs). Maximum of 8 TCs can be created per interface.
+The shaper bw_rlimit parameter is optional.
+
+Example: Sets up two tcs, tc0 and tc1, with 16 queues each and max tx rate set
+to 1Gbit for tc0 and 3Gbit for tc1.
+
+::
+
+ tc qdisc add dev <interface> root mqprio num_tc 2 map 0 0 0 0 1 1 1 1
+ queues 16@0 16@16 hw 1 mode channel shaper bw_rlimit min_rate 1Gbit 2Gbit
+ max_rate 1Gbit 3Gbit
+
+map: priority mapping for up to 16 priorities to tcs (e.g. map 0 0 0 0 1 1 1 1
+sets priorities 0-3 to use tc0 and 4-7 to use tc1)
+
+queues: for each tc, <num queues>@<offset> (e.g. queues 16@0 16@16 assigns
+16 queues to tc0 at offset 0 and 16 queues to tc1 at offset 16. Max total
+number of queues for all tcs is 64 or number of cores, whichever is lower.)
+
+hw 1 mode channel: ‘channel’ with ‘hw’ set to 1 is a new new hardware
+offload mode in mqprio that makes full use of the mqprio options, the
+TCs, the queue configurations, and the QoS parameters.
+
+shaper bw_rlimit: for each tc, sets minimum and maximum bandwidth rates.
+Totals must be equal or less than port speed.
+
+For example: min_rate 1Gbit 3Gbit: Verify bandwidth limit using network
+monitoring tools such as ifstat or sar –n DEV [interval] [number of samples]
+
+NOTE:
+ Setting up channels via ethtool (ethtool -L) is not supported when the
+ TCs are configured using mqprio.
+
+2. Enable HW TC offload on interface::
+
+ # ethtool -K <interface> hw-tc-offload on
+
+3. Apply TCs to ingress (RX) flow of interface::
+
+ # tc qdisc add dev <interface> ingress
+
+NOTES:
+ - Run all tc commands from the iproute2 <pathtoiproute2>/tc/ directory
+ - ADq is not compatible with cloud filters
+ - Setting up channels via ethtool (ethtool -L) is not supported when the TCs
+ are configured using mqprio
+ - You must have iproute2 latest version
+ - NVM version 6.01 or later is required
+ - ADq cannot be enabled when any the following features are enabled: Data
+ Center Bridging (DCB), Multiple Functions per Port (MFP), or Sideband Filters
+ - If another driver (for example, DPDK) has set cloud filters, you cannot
+ enable ADq
+ - Tunnel filters are not supported in ADq. If encapsulated packets do arrive
+ in non-tunnel mode, filtering will be done on the inner headers. For example,
+ for VXLAN traffic in non-tunnel mode, PCTYPE is identified as a VXLAN
+ encapsulated packet, outer headers are ignored. Therefore, inner headers are
+ matched.
+ - If a TC filter on a PF matches traffic over a VF (on the PF), that traffic
+ will be routed to the appropriate queue of the PF, and will not be passed on
+ the VF. Such traffic will end up getting dropped higher up in the TCP/IP
+ stack as it does not match PF address data.
+ - If traffic matches multiple TC filters that point to different TCs, that
+ traffic will be duplicated and sent to all matching TC queues. The hardware
+ switch mirrors the packet to a VSI list when multiple filters are matched.
+
+
+Known Issues/Troubleshooting
+============================
+
+Bonding fails with VFs bound to an Intel(R) Ethernet Controller 700 series device
+---------------------------------------------------------------------------------
+If you bind Virtual Functions (VFs) to an Intel(R) Ethernet Controller 700
+series based device, the VF slaves may fail when they become the active slave.
+If the MAC address of the VF is set by the PF (Physical Function) of the
+device, when you add a slave, or change the active-backup slave, Linux bonding
+tries to sync the backup slave's MAC address to the same MAC address as the
+active slave. Linux bonding will fail at this point. This issue will not occur
+if the VF's MAC address is not set by the PF.
+
+Traffic Is Not Being Passed Between VM and Client
+-------------------------------------------------
+You may not be able to pass traffic between a client system and a
+Virtual Machine (VM) running on a separate host if the Virtual Function
+(VF, or Virtual NIC) is not in trusted mode and spoof checking is enabled
+on the VF. Note that this situation can occur in any combination of client,
+host, and guest operating system. For information on how to set the VF to
+trusted mode, refer to the section "VLAN Tag Packet Steering" in this
+readme document. For information on setting spoof checking, refer to the
+section "MAC and VLAN anti-spoofing feature" in this readme document.
+
+Do not unload port driver if VF with active VM is bound to it
+-------------------------------------------------------------
+Do not unload a port's driver if a Virtual Function (VF) with an active Virtual
+Machine (VM) is bound to it. Doing so will cause the port to appear to hang.
+Once the VM shuts down, or otherwise releases the VF, the command will complete.
+
+Using four traffic classes fails
+--------------------------------
+Do not try to reserve more than three traffic classes in the iavf driver. Doing
+so will fail to set any traffic classes and will cause the driver to write
+errors to stdout. Use a maximum of three queues to avoid this issue.
+
+Multiple log error messages on iavf driver removal
+--------------------------------------------------
+If you have several VFs and you remove the iavf driver, several instances of
+the following log errors are written to the log::
+
+ Unable to send opcode 2 to PF, err I40E_ERR_QUEUE_EMPTY, aq_err ok
+ Unable to send the message to VF 2 aq_err 12
+ ARQ Overflow Error detected
+
+Virtual machine does not get link
+---------------------------------
+If the virtual machine has more than one virtual port assigned to it, and those
+virtual ports are bound to different physical ports, you may not get link on
+all of the virtual ports. The following command may work around the issue::
+
+ # ethtool -r <PF>
+
+Where <PF> is the PF interface in the host, for example: p5p1. You may need to
+run the command more than once to get link on all virtual ports.
+
+MAC address of Virtual Function changes unexpectedly
+----------------------------------------------------
+If a Virtual Function's MAC address is not assigned in the host, then the VF
+(virtual function) driver will use a random MAC address. This random MAC
+address may change each time the VF driver is reloaded. You can assign a static
+MAC address in the host machine. This static MAC address will survive
+a VF driver reload.
+
+Driver Buffer Overflow Fix
+--------------------------
+The fix to resolve CVE-2016-8105, referenced in Intel SA-00069
+https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00069.html
+is included in this and future versions of the driver.
+
+Multiple Interfaces on Same Ethernet Broadcast Network
+------------------------------------------------------
+Due to the default ARP behavior on Linux, it is not possible to have one system
+on two IP networks in the same Ethernet broadcast domain (non-partitioned
+switch) behave as expected. All Ethernet interfaces will respond to IP traffic
+for any IP address assigned to the system. This results in unbalanced receive
+traffic.
+
+If you have multiple interfaces in a server, either turn on ARP filtering by
+entering::
+
+ # echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
+
+NOTE:
+ This setting is not saved across reboots. The configuration change can be
+ made permanent by adding the following line to the file /etc/sysctl.conf::
+
+ net.ipv4.conf.all.arp_filter = 1
+
+Another alternative is to install the interfaces in separate broadcast domains
+(either in different switches or in a switch partitioned to VLANs).
+
+Rx Page Allocation Errors
+-------------------------
+'Page allocation failure. order:0' errors may occur under stress.
+This is caused by the way the Linux kernel reports this stressed condition.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://support.intel.com
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on the supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net
diff --git a/Documentation/networking/device_drivers/ethernet/intel/ice.rst b/Documentation/networking/device_drivers/ethernet/intel/ice.rst
new file mode 100644
index 000000000000..ee43ea57d443
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/ice.rst
@@ -0,0 +1,46 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+==================================================================
+Linux Base Driver for the Intel(R) Ethernet Connection E800 Series
+==================================================================
+
+Intel ice Linux driver.
+Copyright(c) 2018 Intel Corporation.
+
+Contents
+========
+
+- Enabling the driver
+- Support
+
+The driver in this release supports Intel's E800 Series of products. For
+more information, visit Intel's support page at https://support.intel.com.
+
+Enabling the driver
+===================
+The driver is enabled via the standard kernel configuration system,
+using the make command::
+
+ make oldconfig/menuconfig/etc.
+
+The driver is located in the menu structure at:
+
+ -> Device Drivers
+ -> Network device support (NETDEVICES [=y])
+ -> Ethernet driver support
+ -> Intel devices
+ -> Intel(R) Ethernet Connection E800 Series Support
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/igb.rst b/Documentation/networking/device_drivers/ethernet/intel/igb.rst
new file mode 100644
index 000000000000..d46289e182cf
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/igb.rst
@@ -0,0 +1,213 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+==========================================================
+Linux Base Driver for Intel(R) Ethernet Network Connection
+==========================================================
+
+Intel Gigabit Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+
+- Identifying Your Adapter
+- Command Line Parameters
+- Additional Configurations
+- Support
+
+
+Identifying Your Adapter
+========================
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+
+Command Line Parameters
+========================
+If the driver is built as a module, the following optional parameters are used
+by entering them on the command line with the modprobe command using this
+syntax::
+
+ modprobe igb [<option>=<VAL1>,<VAL2>,...]
+
+There needs to be a <VAL#> for each network port in the system supported by
+this driver. The values will be applied to each instance, in function order.
+For example::
+
+ modprobe igb max_vfs=2,4
+
+In this case, there are two network ports supported by igb in the system.
+
+NOTE: A descriptor describes a data buffer and attributes related to the data
+buffer. This information is accessed by the hardware.
+
+max_vfs
+-------
+:Valid Range: 0-7
+
+This parameter adds support for SR-IOV. It causes the driver to spawn up to
+max_vfs worth of virtual functions. If the value is greater than 0 it will
+also force the VMDq parameter to be 1 or more.
+
+The parameters for the driver are referenced by position. Thus, if you have a
+dual port adapter, or more than one adapter in your system, and want N virtual
+functions per port, you must specify a number for each port with each parameter
+separated by a comma. For example::
+
+ modprobe igb max_vfs=4
+
+This will spawn 4 VFs on the first port.
+
+::
+
+ modprobe igb max_vfs=2,4
+
+This will spawn 2 VFs on the first port and 4 VFs on the second port.
+
+NOTE: Caution must be used in loading the driver with these parameters.
+Depending on your system configuration, number of slots, etc., it is impossible
+to predict in all cases where the positions would be on the command line.
+
+NOTE: Neither the device nor the driver control how VFs are mapped into config
+space. Bus layout will vary by operating system. On operating systems that
+support it, you can check sysfs to find the mapping.
+
+NOTE: When either SR-IOV mode or VMDq mode is enabled, hardware VLAN filtering
+and VLAN tag stripping/insertion will remain enabled. Please remove the old
+VLAN filter before the new VLAN filter is added. For example::
+
+ ip link set eth0 vf 0 vlan 100 // set vlan 100 for VF 0
+ ip link set eth0 vf 0 vlan 0 // Delete vlan 100
+ ip link set eth0 vf 0 vlan 200 // set a new vlan 200 for VF 0
+
+Debug
+-----
+:Valid Range: 0-16 (0=none,...,16=all)
+:Default Value: 0
+
+This parameter adjusts the level debug messages displayed in the system logs.
+
+
+Additional Features and Configurations
+======================================
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file:
+
+- For RHEL: /etc/sysconfig/network-scripts/ifcfg-eth<x>
+- For SLES: /etc/sysconfig/network/<config_file>
+
+NOTE: The maximum MTU setting for Jumbo Frames is 9216. This value coincides
+with the maximum Jumbo Frames size of 9234 bytes.
+
+NOTE: Using Jumbo frames at 10 or 100 Mbps is not supported and may result in
+poor performance or loss of link.
+
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+
+https://www.kernel.org/pub/software/network/ethtool/
+
+
+Enabling Wake on LAN (WoL)
+--------------------------
+WoL is configured through the ethtool utility.
+
+WoL will be enabled on the system during the next shut down or reboot. For
+this driver version, in order to enable WoL, the igb driver must be loaded
+prior to shutting down or suspending the system.
+
+NOTE: Wake on LAN is only supported on port A of multi-port devices. Also
+Wake On LAN is not supported for the following device:
+- Intel(R) Gigabit VT Quad Port Server Adapter
+
+
+Multiqueue
+----------
+In this mode, a separate MSI-X vector is allocated for each queue and one for
+"other" interrupts such as link status change and errors. All interrupts are
+throttled via interrupt moderation. Interrupt moderation must be used to avoid
+interrupt storms while the driver is processing one interrupt. The moderation
+value should be at least as large as the expected time for the driver to
+process an interrupt. Multiqueue is off by default.
+
+REQUIREMENTS: MSI-X support is required for Multiqueue. If MSI-X is not found,
+the system will fallback to MSI or to Legacy interrupts. This driver supports
+receive multiqueue on all kernels that support MSI-X.
+
+NOTE: On some kernels a reboot is required to switch between single queue mode
+and multiqueue mode or vice-versa.
+
+
+MAC and VLAN anti-spoofing feature
+----------------------------------
+When a malicious driver attempts to send a spoofed packet, it is dropped by the
+hardware and not transmitted.
+
+An interrupt is sent to the PF driver notifying it of the spoof attempt. When a
+spoofed packet is detected, the PF driver will send the following message to
+the system log (displayed by the "dmesg" command):
+Spoof event(s) detected on VF(n), where n = the VF that attempted to do the
+spoofing
+
+
+Setting MAC Address, VLAN and Rate Limit Using IProute2 Tool
+------------------------------------------------------------
+You can set a MAC address of a Virtual Function (VF), a default VLAN and the
+rate limit using the IProute2 tool. Download the latest version of the
+IProute2 tool from Sourceforge if your version does not have all the features
+you require.
+
+Credit Based Shaper (Qav Mode)
+------------------------------
+When enabling the CBS qdisc in the hardware offload mode, traffic shaping using
+the CBS (described in the IEEE 802.1Q-2018 Section 8.6.8.2 and discussed in the
+Annex L) algorithm will run in the i210 controller, so it's more accurate and
+uses less CPU.
+
+When using offloaded CBS, and the traffic rate obeys the configured rate
+(doesn't go above it), CBS should have little to no effect in the latency.
+
+The offloaded version of the algorithm has some limits, caused by how the idle
+slope is expressed in the adapter's registers. It can only represent idle slopes
+in 16.38431 kbps units, which means that if a idle slope of 2576kbps is
+requested, the controller will be configured to use a idle slope of ~2589 kbps,
+because the driver rounds the value up. For more details, see the comments on
+:c:func:`igb_config_tx_modes()`.
+
+NOTE: This feature is exclusive to i210 models.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/igbvf.rst b/Documentation/networking/device_drivers/ethernet/intel/igbvf.rst
new file mode 100644
index 000000000000..40fa210c5e14
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/igbvf.rst
@@ -0,0 +1,65 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+===========================================================
+Linux Base Virtual Function Driver for Intel(R) 1G Ethernet
+===========================================================
+
+Intel Gigabit Virtual Function Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+- Identifying Your Adapter
+- Additional Configurations
+- Support
+
+This driver supports Intel 82576-based virtual function devices-based virtual
+function devices that can only be activated on kernels that support SR-IOV.
+
+SR-IOV requires the correct platform and OS support.
+
+The guest OS loading this driver must support MSI-X interrupts.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your Intel adapter. All hardware requirements listed apply to use
+with Linux.
+
+Driver information can be obtained using ethtool, lspci, and ifconfig.
+Instructions on updating ethtool can be found in the section Additional
+Configurations later in this document.
+
+NOTE: There is a limit of a total of 32 shared VLANs to 1 or more VFs.
+
+
+Identifying Your Adapter
+========================
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+
+Additional Features and Configurations
+======================================
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+
+https://www.kernel.org/pub/software/network/ethtool/
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/ixgb.rst b/Documentation/networking/device_drivers/ethernet/intel/ixgb.rst
new file mode 100644
index 000000000000..c6a233e68ad6
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/ixgb.rst
@@ -0,0 +1,468 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+=====================================================================
+Linux Base Driver for 10 Gigabit Intel(R) Ethernet Network Connection
+=====================================================================
+
+October 1, 2018
+
+
+Contents
+========
+
+- In This Release
+- Identifying Your Adapter
+- Command Line Parameters
+- Improving Performance
+- Additional Configurations
+- Known Issues/Troubleshooting
+- Support
+
+
+
+In This Release
+===============
+
+This file describes the ixgb Linux Base Driver for the 10 Gigabit Intel(R)
+Network Connection. This driver includes support for Itanium(R)2-based
+systems.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your 10 Gigabit adapter. All hardware requirements listed apply
+to use with Linux.
+
+The following features are available in this kernel:
+ - Native VLANs
+ - Channel Bonding (teaming)
+ - SNMP
+
+Channel Bonding documentation can be found in the Linux kernel source:
+/Documentation/networking/bonding.rst
+
+The driver information previously displayed in the /proc filesystem is not
+supported in this release. Alternatively, you can use ethtool (version 1.6
+or later), lspci, and iproute2 to obtain the same information.
+
+Instructions on updating ethtool can be found in the section "Additional
+Configurations" later in this document.
+
+
+Identifying Your Adapter
+========================
+
+The following Intel network adapters are compatible with the drivers in this
+release:
+
++------------+------------------------------+----------------------------------+
+| Controller | Adapter Name | Physical Layer |
++============+==============================+==================================+
+| 82597EX | Intel(R) PRO/10GbE LR/SR/CX4 | - 10G Base-LR (fiber) |
+| | Server Adapters | - 10G Base-SR (fiber) |
+| | | - 10G Base-CX4 (copper) |
++------------+------------------------------+----------------------------------+
+
+For more information on how to identify your adapter, go to the Adapter &
+Driver ID Guide at:
+
+ https://support.intel.com
+
+
+Command Line Parameters
+=======================
+
+If the driver is built as a module, the following optional parameters are
+used by entering them on the command line with the modprobe command using
+this syntax::
+
+ modprobe ixgb [<option>=<VAL1>,<VAL2>,...]
+
+For example, with two 10GbE PCI adapters, entering::
+
+ modprobe ixgb TxDescriptors=80,128
+
+loads the ixgb driver with 80 TX resources for the first adapter and 128 TX
+resources for the second adapter.
+
+The default value for each parameter is generally the recommended setting,
+unless otherwise noted.
+
+Copybreak
+---------
+:Valid Range: 0-XXXX
+:Default Value: 256
+
+ This is the maximum size of packet that is copied to a new buffer on
+ receive.
+
+Debug
+-----
+:Valid Range: 0-16 (0=none,...,16=all)
+:Default Value: 0
+
+ This parameter adjusts the level of debug messages displayed in the
+ system logs.
+
+FlowControl
+-----------
+:Valid Range: 0-3 (0=none, 1=Rx only, 2=Tx only, 3=Rx&Tx)
+:Default Value: 1 if no EEPROM, otherwise read from EEPROM
+
+ This parameter controls the automatic generation(Tx) and response(Rx) to
+ Ethernet PAUSE frames. There are hardware bugs associated with enabling
+ Tx flow control so beware.
+
+RxDescriptors
+-------------
+:Valid Range: 64-4096
+:Default Value: 1024
+
+ This value is the number of receive descriptors allocated by the driver.
+ Increasing this value allows the driver to buffer more incoming packets.
+ Each descriptor is 16 bytes. A receive buffer is also allocated for
+ each descriptor and can be either 2048, 4056, 8192, or 16384 bytes,
+ depending on the MTU setting. When the MTU size is 1500 or less, the
+ receive buffer size is 2048 bytes. When the MTU is greater than 1500 the
+ receive buffer size will be either 4056, 8192, or 16384 bytes. The
+ maximum MTU size is 16114.
+
+TxDescriptors
+-------------
+:Valid Range: 64-4096
+:Default Value: 256
+
+ This value is the number of transmit descriptors allocated by the driver.
+ Increasing this value allows the driver to queue more transmits. Each
+ descriptor is 16 bytes.
+
+RxIntDelay
+----------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 72
+
+ This value delays the generation of receive interrupts in units of
+ 0.8192 microseconds. Receive interrupt reduction can improve CPU
+ efficiency if properly tuned for specific network traffic. Increasing
+ this value adds extra latency to frame reception and can end up
+ decreasing the throughput of TCP traffic. If the system is reporting
+ dropped receives, this value may be set too high, causing the driver to
+ run out of available receive descriptors.
+
+TxIntDelay
+----------
+:Valid Range: 0-65535 (0=off)
+:Default Value: 32
+
+ This value delays the generation of transmit interrupts in units of
+ 0.8192 microseconds. Transmit interrupt reduction can improve CPU
+ efficiency if properly tuned for specific network traffic. Increasing
+ this value adds extra latency to frame transmission and can end up
+ decreasing the throughput of TCP traffic. If this value is set too high,
+ it will cause the driver to run out of available transmit descriptors.
+
+XsumRX
+------
+:Valid Range: 0-1
+:Default Value: 1
+
+ A value of '1' indicates that the driver should enable IP checksum
+ offload for received packets (both UDP and TCP) to the adapter hardware.
+
+RxFCHighThresh
+--------------
+:Valid Range: 1,536-262,136 (0x600 - 0x3FFF8, 8 byte granularity)
+:Default Value: 196,608 (0x30000)
+
+ Receive Flow control high threshold (when we send a pause frame)
+
+RxFCLowThresh
+-------------
+:Valid Range: 64-262,136 (0x40 - 0x3FFF8, 8 byte granularity)
+:Default Value: 163,840 (0x28000)
+
+ Receive Flow control low threshold (when we send a resume frame)
+
+FCReqTimeout
+------------
+:Valid Range: 1-65535
+:Default Value: 65535
+
+ Flow control request timeout (how long to pause the link partner's tx)
+
+IntDelayEnable
+--------------
+:Value Range: 0,1
+:Default Value: 1
+
+ Interrupt Delay, 0 disables transmit interrupt delay and 1 enables it.
+
+
+Improving Performance
+=====================
+
+With the 10 Gigabit server adapters, the default Linux configuration will
+very likely limit the total available throughput artificially. There is a set
+of configuration changes that, when applied together, will increase the ability
+of Linux to transmit and receive data. The following enhancements were
+originally acquired from settings published at https://www.spec.org/web99/ for
+various submitted results using Linux.
+
+NOTE:
+ These changes are only suggestions, and serve as a starting point for
+ tuning your network performance.
+
+The changes are made in three major ways, listed in order of greatest effect:
+
+- Use ip link to modify the mtu (maximum transmission unit) and the txqueuelen
+ parameter.
+- Use sysctl to modify /proc parameters (essentially kernel tuning)
+- Use setpci to modify the MMRBC field in PCI-X configuration space to increase
+ transmit burst lengths on the bus.
+
+NOTE:
+ setpci modifies the adapter's configuration registers to allow it to read
+ up to 4k bytes at a time (for transmits). However, for some systems the
+ behavior after modifying this register may be undefined (possibly errors of
+ some kind). A power-cycle, hard reset or explicitly setting the e6 register
+ back to 22 (setpci -d 8086:1a48 e6.b=22) may be required to get back to a
+ stable configuration.
+
+- COPY these lines and paste them into ixgb_perf.sh:
+
+::
+
+ #!/bin/bash
+ echo "configuring network performance , edit this file to change the interface
+ or device ID of 10GbE card"
+ # set mmrbc to 4k reads, modify only Intel 10GbE device IDs
+ # replace 1a48 with appropriate 10GbE device's ID installed on the system,
+ # if needed.
+ setpci -d 8086:1a48 e6.b=2e
+ # set the MTU (max transmission unit) - it requires your switch and clients
+ # to change as well.
+ # set the txqueuelen
+ # your ixgb adapter should be loaded as eth1 for this to work, change if needed
+ ip li set dev eth1 mtu 9000 txqueuelen 1000 up
+ # call the sysctl utility to modify /proc/sys entries
+ sysctl -p ./sysctl_ixgb.conf
+
+- COPY these lines and paste them into sysctl_ixgb.conf:
+
+::
+
+ # some of the defaults may be different for your kernel
+ # call this file with sysctl -p <this file>
+ # these are just suggested values that worked well to increase throughput in
+ # several network benchmark tests, your mileage may vary
+
+ ### IPV4 specific settings
+ # turn TCP timestamp support off, default 1, reduces CPU use
+ net.ipv4.tcp_timestamps = 0
+ # turn SACK support off, default on
+ # on systems with a VERY fast bus -> memory interface this is the big gainer
+ net.ipv4.tcp_sack = 0
+ # set min/default/max TCP read buffer, default 4096 87380 174760
+ net.ipv4.tcp_rmem = 10000000 10000000 10000000
+ # set min/pressure/max TCP write buffer, default 4096 16384 131072
+ net.ipv4.tcp_wmem = 10000000 10000000 10000000
+ # set min/pressure/max TCP buffer space, default 31744 32256 32768
+ net.ipv4.tcp_mem = 10000000 10000000 10000000
+
+ ### CORE settings (mostly for socket and UDP effect)
+ # set maximum receive socket buffer size, default 131071
+ net.core.rmem_max = 524287
+ # set maximum send socket buffer size, default 131071
+ net.core.wmem_max = 524287
+ # set default receive socket buffer size, default 65535
+ net.core.rmem_default = 524287
+ # set default send socket buffer size, default 65535
+ net.core.wmem_default = 524287
+ # set maximum amount of option memory buffers, default 10240
+ net.core.optmem_max = 524287
+ # set number of unprocessed input packets before kernel starts dropping them; default 300
+ net.core.netdev_max_backlog = 300000
+
+Edit the ixgb_perf.sh script if necessary to change eth1 to whatever interface
+your ixgb driver is using and/or replace '1a48' with appropriate 10GbE device's
+ID installed on the system.
+
+NOTE:
+ Unless these scripts are added to the boot process, these changes will
+ only last only until the next system reboot.
+
+
+Resolving Slow UDP Traffic
+--------------------------
+If your server does not seem to be able to receive UDP traffic as fast as it
+can receive TCP traffic, it could be because Linux, by default, does not set
+the network stack buffers as large as they need to be to support high UDP
+transfer rates. One way to alleviate this problem is to allow more memory to
+be used by the IP stack to store incoming data.
+
+For instance, use the commands::
+
+ sysctl -w net.core.rmem_max=262143
+
+and::
+
+ sysctl -w net.core.rmem_default=262143
+
+to increase the read buffer memory max and default to 262143 (256k - 1) from
+defaults of max=131071 (128k - 1) and default=65535 (64k - 1). These variables
+will increase the amount of memory used by the network stack for receives, and
+can be increased significantly more if necessary for your application.
+
+
+Additional Configurations
+=========================
+
+Configuring the Driver on Different Distributions
+-------------------------------------------------
+Configuring a network driver to load properly when the system is started is
+distribution dependent. Typically, the configuration process involves adding
+an alias line to /etc/modprobe.conf as well as editing other system startup
+scripts and/or configuration files. Many popular Linux distributions ship
+with tools to make these changes for you. To learn the proper way to
+configure a network device for your system, refer to your distribution
+documentation. If during this process you are asked for the driver or module
+name, the name for the Linux Base Driver for the Intel 10GbE Family of
+Adapters is ixgb.
+
+Viewing Link Messages
+---------------------
+Link messages will not be displayed to the console if the distribution is
+restricting system messages. In order to see network driver link messages on
+your console, set dmesg to eight by entering the following::
+
+ dmesg -n 8
+
+NOTE: This setting is not saved across reboots.
+
+Jumbo Frames
+------------
+The driver supports Jumbo Frames for all adapters. Jumbo Frames support is
+enabled by changing the MTU to a value larger than the default of 1500.
+The maximum value for the MTU is 16114. Use the ip command to
+increase the MTU size. For example::
+
+ ip li set dev ethx mtu 9000
+
+The maximum MTU setting for Jumbo Frames is 16114. This value coincides
+with the maximum Jumbo Frames size of 16128.
+
+Ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The ethtool
+version 1.6 or later is required for this functionality.
+
+The latest release of ethtool can be found from
+https://www.kernel.org/pub/software/network/ethtool/
+
+NOTE:
+ The ethtool version 1.6 only supports a limited set of ethtool options.
+ Support for a more complete ethtool feature set can be enabled by
+ upgrading to the latest version.
+
+NAPI
+----
+NAPI (Rx polling mode) is supported in the ixgb driver.
+
+See https://wiki.linuxfoundation.org/networking/napi for more information on
+NAPI.
+
+
+Known Issues/Troubleshooting
+============================
+
+NOTE:
+ After installing the driver, if your Intel Network Connection is not
+ working, verify in the "In This Release" section of the readme that you have
+ installed the correct driver.
+
+Cable Interoperability Issue with Fujitsu XENPAK Module in SmartBits Chassis
+----------------------------------------------------------------------------
+Excessive CRC errors may be observed if the Intel(R) PRO/10GbE CX4
+Server adapter is connected to a Fujitsu XENPAK CX4 module in a SmartBits
+chassis using 15 m/24AWG cable assemblies manufactured by Fujitsu or Leoni.
+The CRC errors may be received either by the Intel(R) PRO/10GbE CX4
+Server adapter or the SmartBits. If this situation occurs using a different
+cable assembly may resolve the issue.
+
+Cable Interoperability Issues with HP Procurve 3400cl Switch Port
+-----------------------------------------------------------------
+Excessive CRC errors may be observed if the Intel(R) PRO/10GbE CX4 Server
+adapter is connected to an HP Procurve 3400cl switch port using short cables
+(1 m or shorter). If this situation occurs, using a longer cable may resolve
+the issue.
+
+Excessive CRC errors may be observed using Fujitsu 24AWG cable assemblies that
+Are 10 m or longer or where using a Leoni 15 m/24AWG cable assembly. The CRC
+errors may be received either by the CX4 Server adapter or at the switch. If
+this situation occurs, using a different cable assembly may resolve the issue.
+
+Jumbo Frames System Requirement
+-------------------------------
+Memory allocation failures have been observed on Linux systems with 64 MB
+of RAM or less that are running Jumbo Frames. If you are using Jumbo
+Frames, your system may require more than the advertised minimum
+requirement of 64 MB of system memory.
+
+Performance Degradation with Jumbo Frames
+-----------------------------------------
+Degradation in throughput performance may be observed in some Jumbo frames
+environments. If this is observed, increasing the application's socket buffer
+size and/or increasing the /proc/sys/net/ipv4/tcp_*mem entry values may help.
+See the specific application manual and /usr/src/linux*/Documentation/
+networking/ip-sysctl.txt for more details.
+
+Allocating Rx Buffers when Using Jumbo Frames
+---------------------------------------------
+Allocating Rx buffers when using Jumbo Frames on 2.6.x kernels may fail if
+the available memory is heavily fragmented. This issue may be seen with PCI-X
+adapters or with packet split disabled. This can be reduced or eliminated
+by changing the amount of available memory for receive buffer allocation, by
+increasing /proc/sys/vm/min_free_kbytes.
+
+Multiple Interfaces on Same Ethernet Broadcast Network
+------------------------------------------------------
+Due to the default ARP behavior on Linux, it is not possible to have
+one system on two IP networks in the same Ethernet broadcast domain
+(non-partitioned switch) behave as expected. All Ethernet interfaces
+will respond to IP traffic for any IP address assigned to the system.
+This results in unbalanced receive traffic.
+
+If you have multiple interfaces in a server, do either of the following:
+
+ - Turn on ARP filtering by entering::
+
+ echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
+
+ - Install the interfaces in separate broadcast domains - either in
+ different switches or in a switch partitioned to VLANs.
+
+UDP Stress Test Dropped Packet Issue
+--------------------------------------
+Under small packets UDP stress test with 10GbE driver, the Linux system
+may drop UDP packets due to the fullness of socket buffers. You may want
+to change the driver's Flow Control variables to the minimum value for
+controlling packet reception.
+
+Tx Hangs Possible Under Stress
+------------------------------
+Under stress conditions, if TX hangs occur, turning off TSO
+"ethtool -K eth0 tso off" may resolve the problem.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net
diff --git a/Documentation/networking/device_drivers/ethernet/intel/ixgbe.rst b/Documentation/networking/device_drivers/ethernet/intel/ixgbe.rst
new file mode 100644
index 000000000000..f1d5233e5e51
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/ixgbe.rst
@@ -0,0 +1,541 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+===========================================================================
+Linux Base Driver for the Intel(R) Ethernet 10 Gigabit PCI Express Adapters
+===========================================================================
+
+Intel 10 Gigabit Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+
+- Identifying Your Adapter
+- Command Line Parameters
+- Additional Configurations
+- Known Issues
+- Support
+
+Identifying Your Adapter
+========================
+The driver is compatible with devices based on the following:
+
+ * Intel(R) Ethernet Controller 82598
+ * Intel(R) Ethernet Controller 82599
+ * Intel(R) Ethernet Controller X520
+ * Intel(R) Ethernet Controller X540
+ * Intel(R) Ethernet Controller x550
+ * Intel(R) Ethernet Controller X552
+ * Intel(R) Ethernet Controller X553
+
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+SFP+ Devices with Pluggable Optics
+----------------------------------
+
+82599-BASED ADAPTERS
+~~~~~~~~~~~~~~~~~~~~
+NOTES:
+- If your 82599-based Intel(R) Network Adapter came with Intel optics or is an
+Intel(R) Ethernet Server Adapter X520-2, then it only supports Intel optics
+and/or the direct attach cables listed below.
+- When 82599-based SFP+ devices are connected back to back, they should be set
+to the same Speed setting via ethtool. Results may vary if you mix speed
+settings.
+
++---------------+---------------------------------------+------------------+
+| Supplier | Type | Part Numbers |
++===============+=======================================+==================+
+| SR Modules |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | FTLX8571D3BCV-IT |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | AFBR-703SDZ-IN2 |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | AFBR-703SDDZ-IN1 |
++---------------+---------------------------------------+------------------+
+| LR Modules |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | FTLX1471D3BCV-IT |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | AFCT-701SDZ-IN2 |
++---------------+---------------------------------------+------------------+
+| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | AFCT-701SDDZ-IN1 |
++---------------+---------------------------------------+------------------+
+
+The following is a list of 3rd party SFP+ modules that have received some
+testing. Not all modules are applicable to all devices.
+
++---------------+---------------------------------------+------------------+
+| Supplier | Type | Part Numbers |
++===============+=======================================+==================+
+| Finisar | SFP+ SR bailed, 10g single rate | FTLX8571D3BCL |
++---------------+---------------------------------------+------------------+
+| Avago | SFP+ SR bailed, 10g single rate | AFBR-700SDZ |
++---------------+---------------------------------------+------------------+
+| Finisar | SFP+ LR bailed, 10g single rate | FTLX1471D3BCL |
++---------------+---------------------------------------+------------------+
+| Finisar | DUAL RATE 1G/10G SFP+ SR (No Bail) | FTLX8571D3QCV-IT |
++---------------+---------------------------------------+------------------+
+| Avago | DUAL RATE 1G/10G SFP+ SR (No Bail) | AFBR-703SDZ-IN1 |
++---------------+---------------------------------------+------------------+
+| Finisar | DUAL RATE 1G/10G SFP+ LR (No Bail) | FTLX1471D3QCV-IT |
++---------------+---------------------------------------+------------------+
+| Avago | DUAL RATE 1G/10G SFP+ LR (No Bail) | AFCT-701SDZ-IN1 |
++---------------+---------------------------------------+------------------+
+| Finisar | 1000BASE-T SFP | FCLF8522P2BTL |
++---------------+---------------------------------------+------------------+
+| Avago | 1000BASE-T | ABCU-5710RZ |
++---------------+---------------------------------------+------------------+
+| HP | 1000BASE-SX SFP | 453153-001 |
++---------------+---------------------------------------+------------------+
+
+82599-based adapters support all passive and active limiting direct attach
+cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications.
+
+Laser turns off for SFP+ when ifconfig ethX down
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+"ifconfig ethX down" turns off the laser for 82599-based SFP+ fiber adapters.
+"ifconfig ethX up" turns on the laser.
+Alternatively, you can use "ip link set [down/up] dev ethX" to turn the
+laser off and on.
+
+
+82599-based QSFP+ Adapters
+~~~~~~~~~~~~~~~~~~~~~~~~~~
+NOTES:
+- If your 82599-based Intel(R) Network Adapter came with Intel optics, it only
+supports Intel optics.
+- 82599-based QSFP+ adapters only support 4x10 Gbps connections. 1x40 Gbps
+connections are not supported. QSFP+ link partners must be configured for
+4x10 Gbps.
+- 82599-based QSFP+ adapters do not support automatic link speed detection.
+The link speed must be configured to either 10 Gbps or 1 Gbps to match the link
+partners speed capabilities. Incorrect speed configurations will result in
+failure to link.
+- Intel(R) Ethernet Converged Network Adapter X520-Q1 only supports the optics
+and direct attach cables listed below.
+
++---------------+---------------------------------------+------------------+
+| Supplier | Type | Part Numbers |
++===============+=======================================+==================+
+| Intel | DUAL RATE 1G/10G QSFP+ SRL (bailed) | E10GQSFPSR |
++---------------+---------------------------------------+------------------+
+
+82599-based QSFP+ adapters support all passive and active limiting QSFP+
+direct attach cables that comply with SFF-8436 v4.1 specifications.
+
+82598-BASED ADAPTERS
+~~~~~~~~~~~~~~~~~~~~
+NOTES:
+- Intel(r) Ethernet Network Adapters that support removable optical modules
+only support their original module type (for example, the Intel(R) 10 Gigabit
+SR Dual Port Express Module only supports SR optical modules). If you plug in
+a different type of module, the driver will not load.
+- Hot Swapping/hot plugging optical modules is not supported.
+- Only single speed, 10 gigabit modules are supported.
+- LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module
+types are not supported. Please see your system documentation for details.
+
+The following is a list of SFP+ modules and direct attach cables that have
+received some testing. Not all modules are applicable to all devices.
+
++---------------+---------------------------------------+------------------+
+| Supplier | Type | Part Numbers |
++===============+=======================================+==================+
+| Finisar | SFP+ SR bailed, 10g single rate | FTLX8571D3BCL |
++---------------+---------------------------------------+------------------+
+| Avago | SFP+ SR bailed, 10g single rate | AFBR-700SDZ |
++---------------+---------------------------------------+------------------+
+| Finisar | SFP+ LR bailed, 10g single rate | FTLX1471D3BCL |
++---------------+---------------------------------------+------------------+
+
+82598-based adapters support all passive direct attach cables that comply with
+SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach cables
+are not supported.
+
+Third party optic modules and cables referred to above are listed only for the
+purpose of highlighting third party specifications and potential
+compatibility, and are not recommendations or endorsements or sponsorship of
+any third party's product by Intel. Intel is not endorsing or promoting
+products made by any third party and the third party reference is provided
+only to share information regarding certain optic modules and cables with the
+above specifications. There may be other manufacturers or suppliers, producing
+or supplying optic modules and cables with similar or matching descriptions.
+Customers must use their own discretion and diligence to purchase optic
+modules and cables from any third party of their choice. Customers are solely
+responsible for assessing the suitability of the product and/or devices and
+for the selection of the vendor for purchasing any product. THE OPTIC MODULES
+AND CABLES REFERRED TO ABOVE ARE NOT WARRANTED OR SUPPORTED BY INTEL. INTEL
+ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED
+WARRANTY, RELATING TO SALE AND/OR USE OF SUCH THIRD PARTY PRODUCTS OR
+SELECTION OF VENDOR BY CUSTOMERS.
+
+Command Line Parameters
+=======================
+
+max_vfs
+-------
+:Valid Range: 1-63
+
+This parameter adds support for SR-IOV. It causes the driver to spawn up to
+max_vfs worth of virtual functions.
+If the value is greater than 0 it will also force the VMDq parameter to be 1 or
+more.
+
+NOTE: This parameter is only used on kernel 3.7.x and below. On kernel 3.8.x
+and above, use sysfs to enable VFs. Also, for Red Hat distributions, this
+parameter is only used on version 6.6 and older. For version 6.7 and newer, use
+sysfs. For example::
+
+ #echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs // enable VFs
+ #echo 0 > /sys/class/net/$dev/device/sriov_numvfs //disable VFs
+
+The parameters for the driver are referenced by position. Thus, if you have a
+dual port adapter, or more than one adapter in your system, and want N virtual
+functions per port, you must specify a number for each port with each parameter
+separated by a comma. For example::
+
+ modprobe ixgbe max_vfs=4
+
+This will spawn 4 VFs on the first port.
+
+::
+
+ modprobe ixgbe max_vfs=2,4
+
+This will spawn 2 VFs on the first port and 4 VFs on the second port.
+
+NOTE: Caution must be used in loading the driver with these parameters.
+Depending on your system configuration, number of slots, etc., it is impossible
+to predict in all cases where the positions would be on the command line.
+
+NOTE: Neither the device nor the driver control how VFs are mapped into config
+space. Bus layout will vary by operating system. On operating systems that
+support it, you can check sysfs to find the mapping.
+
+NOTE: When either SR-IOV mode or VMDq mode is enabled, hardware VLAN filtering
+and VLAN tag stripping/insertion will remain enabled. Please remove the old
+VLAN filter before the new VLAN filter is added. For example,
+
+::
+
+ ip link set eth0 vf 0 vlan 100 // set VLAN 100 for VF 0
+ ip link set eth0 vf 0 vlan 0 // Delete VLAN 100
+ ip link set eth0 vf 0 vlan 200 // set a new VLAN 200 for VF 0
+
+With kernel 3.6, the driver supports the simultaneous usage of max_vfs and DCB
+features, subject to the constraints described below. Prior to kernel 3.6, the
+driver did not support the simultaneous operation of max_vfs greater than 0 and
+the DCB features (multiple traffic classes utilizing Priority Flow Control and
+Extended Transmission Selection).
+
+When DCB is enabled, network traffic is transmitted and received through
+multiple traffic classes (packet buffers in the NIC). The traffic is associated
+with a specific class based on priority, which has a value of 0 through 7 used
+in the VLAN tag. When SR-IOV is not enabled, each traffic class is associated
+with a set of receive/transmit descriptor queue pairs. The number of queue
+pairs for a given traffic class depends on the hardware configuration. When
+SR-IOV is enabled, the descriptor queue pairs are grouped into pools. The
+Physical Function (PF) and each Virtual Function (VF) is allocated a pool of
+receive/transmit descriptor queue pairs. When multiple traffic classes are
+configured (for example, DCB is enabled), each pool contains a queue pair from
+each traffic class. When a single traffic class is configured in the hardware,
+the pools contain multiple queue pairs from the single traffic class.
+
+The number of VFs that can be allocated depends on the number of traffic
+classes that can be enabled. The configurable number of traffic classes for
+each enabled VF is as follows:
+0 - 15 VFs = Up to 8 traffic classes, depending on device support
+16 - 31 VFs = Up to 4 traffic classes
+32 - 63 VFs = 1 traffic class
+
+When VFs are configured, the PF is allocated one pool as well. The PF supports
+the DCB features with the constraint that each traffic class will only use a
+single queue pair. When zero VFs are configured, the PF can support multiple
+queue pairs per traffic class.
+
+allow_unsupported_sfp
+---------------------
+:Valid Range: 0,1
+:Default Value: 0 (disabled)
+
+This parameter allows unsupported and untested SFP+ modules on 82599-based
+adapters, as long as the type of module is known to the driver.
+
+debug
+-----
+:Valid Range: 0-16 (0=none,...,16=all)
+:Default Value: 0
+
+This parameter adjusts the level of debug messages displayed in the system
+logs.
+
+
+Additional Features and Configurations
+======================================
+
+Flow Control
+------------
+Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable
+receiving and transmitting pause frames for ixgbe. When transmit is enabled,
+pause frames are generated when the receive packet buffer crosses a predefined
+threshold. When receive is enabled, the transmit unit will halt for the time
+delay specified when a pause frame is received.
+
+NOTE: You must have a flow control capable link partner.
+
+Flow Control is enabled by default.
+
+Use ethtool to change the flow control settings. To enable or disable Rx or
+Tx Flow Control::
+
+ ethtool -A eth? rx <on|off> tx <on|off>
+
+Note: This command only enables or disables Flow Control if auto-negotiation is
+disabled. If auto-negotiation is enabled, this command changes the parameters
+used for auto-negotiation with the link partner.
+
+To enable or disable auto-negotiation::
+
+ ethtool -s eth? autoneg <on|off>
+
+Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending
+on your device, you may not be able to change the auto-negotiation setting.
+
+NOTE: For 82598 backplane cards entering 1 gigabit mode, flow control default
+behavior is changed to off. Flow control in 1 gigabit mode on these devices can
+lead to transmit hangs.
+
+Intel(R) Ethernet Flow Director
+-------------------------------
+The Intel Ethernet Flow Director performs the following tasks:
+
+- Directs receive packets according to their flows to different queues.
+- Enables tight control on routing a flow in the platform.
+- Matches flows and CPU cores for flow affinity.
+- Supports multiple parameters for flexible flow classification and load
+ balancing (in SFP mode only).
+
+NOTE: Intel Ethernet Flow Director masking works in the opposite manner from
+subnet masking. In the following command::
+
+ #ethtool -N eth11 flow-type ip4 src-ip 172.4.1.2 m 255.0.0.0 dst-ip \
+ 172.21.1.1 m 255.128.0.0 action 31
+
+The src-ip value that is written to the filter will be 0.4.1.2, not 172.0.0.0
+as might be expected. Similarly, the dst-ip value written to the filter will be
+0.21.1.1, not 172.0.0.0.
+
+To enable or disable the Intel Ethernet Flow Director::
+
+ # ethtool -K ethX ntuple <on|off>
+
+When disabling ntuple filters, all the user programmed filters are flushed from
+the driver cache and hardware. All needed filters must be re-added when ntuple
+is re-enabled.
+
+To add a filter that directs packet to queue 2, use -U or -N switch::
+
+ # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \
+ 192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1]
+
+To see the list of filters currently present::
+
+ # ethtool <-u|-n> ethX
+
+Sideband Perfect Filters
+------------------------
+Sideband Perfect Filters are used to direct traffic that matches specified
+characteristics. They are enabled through ethtool's ntuple interface. To add a
+new filter use the following command::
+
+ ethtool -U <device> flow-type <type> src-ip <ip> dst-ip <ip> src-port <port> \
+ dst-port <port> action <queue>
+
+Where:
+ <device> - the ethernet device to program
+ <type> - can be ip4, tcp4, udp4, or sctp4
+ <ip> - the IP address to match on
+ <port> - the port number to match on
+ <queue> - the queue to direct traffic towards (-1 discards the matched traffic)
+
+Use the following command to delete a filter::
+
+ ethtool -U <device> delete <N>
+
+Where <N> is the filter id displayed when printing all the active filters, and
+may also have been specified using "loc <N>" when adding the filter.
+
+The following example matches TCP traffic sent from 192.168.0.1, port 5300,
+directed to 192.168.0.5, port 80, and sends it to queue 7::
+
+ ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5 \
+ src-port 5300 dst-port 80 action 7
+
+For each flow-type, the programmed filters must all have the same matching
+input set. For example, issuing the following two commands is acceptable::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10
+
+Issuing the next two commands, however, is not acceptable, since the first
+specifies src-ip and the second specifies dst-ip::
+
+ ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7
+ ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10
+
+The second command will fail with an error. You may program multiple filters
+with the same fields, using different values, but, on one device, you may not
+program two TCP4 filters with different matching fields.
+
+Matching on a sub-portion of a field is not supported by the ixgbe driver, thus
+partial mask fields are not supported.
+
+To create filters that direct traffic to a specific Virtual Function, use the
+"user-def" parameter. Specify the user-def as a 64 bit value, where the lower 32
+bits represents the queue number, while the next 8 bits represent which VF.
+Note that 0 is the PF, so the VF identifier is offset by 1. For example::
+
+ ... user-def 0x800000002 ...
+
+specifies to direct traffic to Virtual Function 7 (8 minus 1) into queue 2 of
+that VF.
+
+Note that these filters will not break internal routing rules, and will not
+route traffic that otherwise would not have been sent to the specified Virtual
+Function.
+
+Jumbo Frames
+------------
+Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU)
+to a value larger than the default value of 1500.
+
+Use the ifconfig command to increase the MTU size. For example, enter the
+following where <x> is the interface number::
+
+ ifconfig eth<x> mtu 9000 up
+
+Alternatively, you can use the ip command as follows::
+
+ ip link set mtu 9000 dev eth<x>
+ ip link set up dev eth<x>
+
+This setting is not saved across reboots. The setting change can be made
+permanent by adding 'MTU=9000' to the file::
+
+ /etc/sysconfig/network-scripts/ifcfg-eth<x> // for RHEL
+ /etc/sysconfig/network/<config_file> // for SLES
+
+NOTE: The maximum MTU setting for Jumbo Frames is 9710. This value coincides
+with the maximum Jumbo Frames size of 9728 bytes.
+
+NOTE: This driver will attempt to use multiple page sized buffers to receive
+each jumbo packet. This should help to avoid buffer starvation issues when
+allocating receive packets.
+
+NOTE: For 82599-based network connections, if you are enabling jumbo frames in
+a virtual function (VF), jumbo frames must first be enabled in the physical
+function (PF). The VF MTU setting cannot be larger than the PF MTU.
+
+Generic Receive Offload, aka GRO
+--------------------------------
+The driver supports the in-kernel software implementation of GRO. GRO has
+shown that by coalescing Rx traffic into larger chunks of data, CPU
+utilization can be significantly reduced when under large Rx load. GRO is an
+evolution of the previously-used LRO interface. GRO is able to coalesce
+other protocols besides TCP. It's also safe to use with configurations that
+are problematic for LRO, namely bridging and iSCSI.
+
+Data Center Bridging (DCB)
+--------------------------
+NOTE:
+The kernel assumes that TC0 is available, and will disable Priority Flow
+Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is
+enabled when setting up DCB on your switch.
+
+DCB is a configuration Quality of Service implementation in hardware. It uses
+the VLAN priority tag (802.1p) to filter traffic. That means that there are 8
+different priorities that traffic can be filtered into. It also enables
+priority flow control (802.1Qbb) which can limit or eliminate the number of
+dropped packets during network stress. Bandwidth can be allocated to each of
+these priorities, which is enforced at the hardware level (802.1Qaz).
+
+Adapter firmware implements LLDP and DCBX protocol agents as per 802.1AB and
+802.1Qaz respectively. The firmware based DCBX agent runs in willing mode only
+and can accept settings from a DCBX capable peer. Software configuration of
+DCBX parameters via dcbtool/lldptool are not supported.
+
+The ixgbe driver implements the DCB netlink interface layer to allow user-space
+to communicate with the driver and query DCB configuration for the port.
+
+ethtool
+-------
+The driver utilizes the ethtool interface for driver configuration and
+diagnostics, as well as displaying statistical information. The latest ethtool
+version is required for this functionality. Download it at:
+https://www.kernel.org/pub/software/network/ethtool/
+
+FCoE
+----
+The ixgbe driver supports Fiber Channel over Ethernet (FCoE) and Data Center
+Bridging (DCB). This code has no default effect on the regular driver
+operation. Configuring DCB and FCoE is outside the scope of this README. Refer
+to http://www.open-fcoe.org/ for FCoE project information and contact
+ixgbe-eedc@lists.sourceforge.net for DCB information.
+
+MAC and VLAN anti-spoofing feature
+----------------------------------
+When a malicious driver attempts to send a spoofed packet, it is dropped by the
+hardware and not transmitted.
+
+An interrupt is sent to the PF driver notifying it of the spoof attempt. When a
+spoofed packet is detected, the PF driver will send the following message to
+the system log (displayed by the "dmesg" command)::
+
+ ixgbe ethX: ixgbe_spoof_check: n spoofed packets detected
+
+where "x" is the PF interface number; and "n" is number of spoofed packets.
+NOTE: This feature can be disabled for a specific Virtual Function (VF)::
+
+ ip link set <pf dev> vf <vf id> spoofchk {off|on}
+
+IPsec Offload
+-------------
+The ixgbe driver supports IPsec Hardware Offload. When creating Security
+Associations with "ip xfrm ..." the 'offload' tag option can be used to
+register the IPsec SA with the driver in order to get higher throughput in
+the secure communications.
+
+The offload is also supported for ixgbe's VFs, but the VF must be set as
+'trusted' and the support must be enabled with::
+
+ ethtool --set-priv-flags eth<x> vf-ipsec on
+ ip link set eth<x> vf <y> trust on
+
+
+Known Issues/Troubleshooting
+============================
+
+Enabling SR-IOV in a 64-bit Microsoft Windows Server 2012/R2 guest OS
+---------------------------------------------------------------------
+Linux KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM.
+This includes traditional PCIe devices, as well as SR-IOV-capable devices based
+on the Intel Ethernet Controller XL710.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.
diff --git a/Documentation/networking/device_drivers/ethernet/intel/ixgbevf.rst b/Documentation/networking/device_drivers/ethernet/intel/ixgbevf.rst
new file mode 100644
index 000000000000..76bbde736f21
--- /dev/null
+++ b/Documentation/networking/device_drivers/ethernet/intel/ixgbevf.rst
@@ -0,0 +1,67 @@
+.. SPDX-License-Identifier: GPL-2.0+
+
+============================================================
+Linux Base Virtual Function Driver for Intel(R) 10G Ethernet
+============================================================
+
+Intel 10 Gigabit Virtual Function Linux driver.
+Copyright(c) 1999-2018 Intel Corporation.
+
+Contents
+========
+
+- Identifying Your Adapter
+- Known Issues
+- Support
+
+This driver supports 82599, X540, X550, and X552-based virtual function devices
+that can only be activated on kernels that support SR-IOV.
+
+For questions related to hardware requirements, refer to the documentation
+supplied with your Intel adapter. All hardware requirements listed apply to use
+with Linux.
+
+
+Identifying Your Adapter
+========================
+The driver is compatible with devices based on the following:
+
+ * Intel(R) Ethernet Controller 82598
+ * Intel(R) Ethernet Controller 82599
+ * Intel(R) Ethernet Controller X520
+ * Intel(R) Ethernet Controller X540
+ * Intel(R) Ethernet Controller x550
+ * Intel(R) Ethernet Controller X552
+ * Intel(R) Ethernet Controller X553
+
+For information on how to identify your adapter, and for the latest Intel
+network drivers, refer to the Intel Support website:
+https://www.intel.com/support
+
+Known Issues/Troubleshooting
+============================
+
+SR-IOV requires the correct platform and OS support.
+
+The guest OS loading this driver must support MSI-X interrupts.
+
+This driver is only supported as a loadable module at this time. Intel is not
+supplying patches against the kernel source to allow for static linking of the
+drivers.
+
+VLANs: There is a limit of a total of 64 shared VLANs to 1 or more VFs.
+
+
+Support
+=======
+For general information, go to the Intel support website at:
+
+https://www.intel.com/support/
+
+or the Intel Wired Networking project hosted by Sourceforge at:
+
+https://sourceforge.net/projects/e1000
+
+If an issue is identified with the released source code on a supported kernel
+with a supported adapter, email the specific information related to the issue
+to e1000-devel@lists.sf.net.