diff --git a/Documentation/leds/leds-lm3556.rst b/Documentation/leds/leds-lm3556.rst
index 1ef17d7d800e..32e3983473ba 100644
--- a/Documentation/leds/leds-lm3556.rst
+++ b/Documentation/leds/leds-lm3556.rst
@@ -23,7 +23,7 @@ from 93.75 mA to 1500 mA.The Flash currents are adjusted via the CURRENT
CONTROL REGISTER(0x09).Flash mode is activated by the ENABLE REGISTER(0x0A),
or by pulling the STROBE pin HIGH.
-LM3556 Flash can be controlled through sys/class/leds/flash/brightness file
+LM3556 Flash can be controlled through /sys/class/leds/flash/brightness file
* if STROBE pin is enabled, below example control brightness only, and
ON / OFF will be controlled by STROBE pin.
@@ -32,17 +32,17 @@ Flash Example:
OFF::
- #echo 0 > sys/class/leds/flash/brightness
+ #echo 0 > /sys/class/leds/flash/brightness
93.75 mA::
- #echo 1 > sys/class/leds/flash/brightness
+ #echo 1 > /sys/class/leds/flash/brightness
...
1500 mA::
- #echo 16 > sys/class/leds/flash/brightness
+ #echo 16 > /sys/class/leds/flash/brightness
Torch Mode
^^^^^^^^^^
@@ -51,7 +51,7 @@ In Torch Mode, the current source(LED) is programmed via the CURRENT CONTROL
REGISTER(0x09).Torch Mode is activated by the ENABLE REGISTER(0x0A) or by the
hardware TORCH input.
-LM3556 torch can be controlled through sys/class/leds/torch/brightness file.
+LM3556 torch can be controlled through /sys/class/leds/torch/brightness file.
* if TORCH pin is enabled, below example control brightness only,
and ON / OFF will be controlled by TORCH pin.
@@ -59,22 +59,22 @@ Torch Example:
OFF::
- #echo 0 > sys/class/leds/torch/brightness
+ #echo 0 > /sys/class/leds/torch/brightness
46.88 mA::
- #echo 1 > sys/class/leds/torch/brightness
+ #echo 1 > /sys/class/leds/torch/brightness
...
375 mA::
- #echo 8 > sys/class/leds/torch/brightness
+ #echo 8 > /sys/class/leds/torch/brightness
Indicator Mode
^^^^^^^^^^^^^^
-Indicator pattern can be set through sys/class/leds/indicator/pattern file,
+Indicator pattern can be set through /sys/class/leds/indicator/pattern file,
and 4 patterns are pre-defined in indicator_pattern array.
According to N-lank, Pulse time and N Period values, different pattern wiill
@@ -87,13 +87,13 @@ Indicator pattern example:
pattern 0::
- #echo 0 > sys/class/leds/indicator/pattern
+ #echo 0 > /sys/class/leds/indicator/pattern
...
pattern 3::
- #echo 3 > sys/class/leds/indicator/pattern
+ #echo 3 > /sys/class/leds/indicator/pattern
Indicator brightness can be controlled through
sys/class/leds/indicator/brightness file.
@@ -102,17 +102,17 @@ Example:
OFF::
- #echo 0 > sys/class/leds/indicator/brightness
+ #echo 0 > /sys/class/leds/indicator/brightness
5.86 mA::
- #echo 1 > sys/class/leds/indicator/brightness
+ #echo 1 > /sys/class/leds/indicator/brightness
...
46.875mA::
- #echo 8 > sys/class/leds/indicator/brightness
+ #echo 8 > /sys/class/leds/indicator/brightness
Notes
-----