summaryrefslogtreecommitdiffstats
path: root/drivers/thunderbolt/domain.c
AgeCommit message (Collapse)Author
2017-06-09thunderbolt: Add support for host and device NVM firmware upgradeMika Westerberg
Starting from Intel Falcon Ridge the NVM firmware can be upgraded by using DMA configuration based mailbox commands. If we detect that the host or device (device support starts from Intel Alpine Ridge) has the DMA configuration based mailbox we expose NVM information to the userspace as two separate Linux NVMem devices: nvm_active and nvm_non_active. The former is read-only portion of the active NVM which firmware upgrade tools can be use to find out suitable NVM image if the device identification strings are not enough. The latter is write-only portion where the new NVM image is to be written by the userspace. It is up to the userspace to find out right NVM image (the kernel does very minimal validation). The ICM firmware itself authenticates the new NVM firmware and fails the operation if it is not what is expected. We also expose two new sysfs files per each switch: nvm_version and nvm_authenticate which can be used to read the active NVM version and start the upgrade process. We also introduce safe mode which is the mode a switch goes when it does not have properly authenticated firmware. In this mode the switch only accepts a couple of commands including flashing a new NVM firmware image and triggering power cycle. This code is based on the work done by Amir Levy and Michael Jamet. Signed-off-by: Michael Jamet <michael.jamet@intel.com> Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Andreas Noever <andreas.noever@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-06-09thunderbolt: Add support for Internal Connection Manager (ICM)Mika Westerberg
Starting from Intel Falcon Ridge the internal connection manager running on the Thunderbolt host controller has been supporting 4 security levels. One reason for this is to prevent DMA attacks and only allow connecting devices the user trusts. The internal connection manager (ICM) is the preferred way of connecting Thunderbolt devices over software only implementation typically used on Macs. The driver communicates with ICM using special Thunderbolt ring 0 (control channel) messages. In order to handle these messages we add support for the ICM messages to the control channel. The security levels are as follows: none - No security, all tunnels are created automatically user - User needs to approve the device before tunnels are created secure - User need to approve the device before tunnels are created. The device is sent a challenge on future connects to be able to verify it is actually the approved device. dponly - Only Display Port and USB tunnels can be created and those are created automatically. The security levels are typically configurable from the system BIOS and by default it is set to "user" on many systems. In this patch each Thunderbolt device will have either one or two new sysfs attributes: authorized and key. The latter appears for devices that support secure connect. In order to identify the device the user can read identication information, including UUID and name of the device from sysfs and based on that make a decision to authorize the device. The device is authorized by simply writing 1 to the "authorized" sysfs attribute. This is following the USB bus device authorization mechanism. The secure connect requires an additional challenge step (writing 2 to the "authorized" attribute) in future connects when the key has already been stored to the NVM of the device. Non-ICM systems (before Alpine Ridge) continue to use the existing functionality and the security level is set to none. For systems with Alpine Ridge, even on Apple hardware, we will use ICM. This code is based on the work done by Amir Levy and Michael Jamet. Signed-off-by: Michael Jamet <michael.jamet@intel.com> Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Andreas Noever <andreas.noever@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-06-09thunderbolt: Let the connection manager handle all notificationsMika Westerberg
Currently the control channel (ctl.c) handles the one supported notification (PLUG_EVENT) and sends back ACK accordingly. However, we are going to add support for the internal connection manager (ICM) that needs to handle a different notifications. So instead of dealing everything in the control channel, we change the callback to take an arbitrary thunderbolt packet and convert the native connection manager to handle the event itself. In addition we only push replies we know of to the response FIFO. Everything else is treated as notification (or request) and is expected to be dealt by the connection manager implementation. Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Michael Jamet <michael.jamet@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Andreas Noever <andreas.noever@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-06-09thunderbolt: Introduce thunderbolt bus and connection managerMika Westerberg
Thunderbolt fabric consists of one or more switches. This fabric is called domain and it is controlled by an entity called connection manager. The connection manager can be either internal (driven by a firmware running on the host controller) or external (software driver). This driver currently implements support for the latter. In order to manage switches and their properties more easily we model this domain structure as a Linux bus. Each host controller adds a domain device to this bus, and these devices are named as domainN where N stands for index or id of the current domain. We then abstract connection manager specific operations into a new structure tb_cm_ops and convert the existing tb.c to fill those accordingly. This makes it easier to add support for the internal connection manager in subsequent patches. Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Michael Jamet <michael.jamet@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Andreas Noever <andreas.noever@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>