ACPI Time and Alarm (TAD) device attributes. What: /sys/bus/platform/devices/ACPI000E:00/caps Date: March 2018 Contact: Rafael J. Wysocki Description: (RO) Hexadecimal bitmask of the TAD attributes are reported by the platform firmware (see ACPI 6.2, section 9.18.2): ======= ====================================================== BIT(0): AC wakeup implemented if set BIT(1): DC wakeup implemented if set BIT(2): Get/set real time features implemented if set BIT(3): Real time accuracy in milliseconds if set BIT(4): Correct status reported for wakeups from S4/S5 if set BIT(5): The AC timer wakes up from S4 if set BIT(6): The AC timer wakes up from S5 if set BIT(7): The DC timer wakes up from S4 if set BIT(8): The DC timer wakes up from S5 if set ======= ====================================================== The other bits are reserved. What: /sys/bus/platform/devices/ACPI000E:00/ac_alarm Date: March 2018 Contact: Rafael J. Wysocki Description: (RW) The AC alarm timer value. Reads return the current AC alarm timer value in seconds or "disabled", if the AC alarm is not set to wake up the system. Write a new AC alarm timer value in seconds or "disabled" to it to set the AC alarm timer or to disable it, respectively. If the AC alarm timer is set through this attribute and it expires, it will immediately wake up the system from the S3 sleep state (and from S4/S5 too if supported) until its status is explicitly cleared via the ac_status attribute. What: /sys/bus/platform/devices/ACPI000E:00/ac_policy Date: March 2018 Contact: Rafael J. Wysocki Description: (RW) The AC alarm expired timer wake policy (see ACPI 6.2, Section 9.18 for details). Reads return the current expired timer wake delay for the AC alarm timer or "never", if the policy is to discard AC timer wakeups if the system is on DC power. Write a new expired timer wake delay for the AC alarm timer in seconds or "never" to it to set the expired timer wake delay for the AC alarm timer or to set its expired wake policy to discard wakeups if the system is on DC power, respectively. What: /sys/bus/platform/devices/ACPI000E:00/ac_status Date: March 2018 Contact: Rafael J. Wysocki Description: (RW) The AC alarm status. Reads return a hexadecimal bitmask representing the AC alarm timer status with the following meaning of bits (see ACPI 6.2, Section 9.18.5): ======= ====================================================== Bit(0): The timer has expired if set. Bit(1): The timer has woken up the system from a sleep state (S3 or S4/S5 if supported) if set. ======= ====================================================== The other bits are reserved. Reads also cause the AC alarm timer status to be reset. Another way to reset the status of the AC alarm timer is to write (the number) 0 to this file. If the status return value indicates that the timer has expired, it will immediately wake up the system from the S3 sleep state (and from S4/S5 too if supported) until its status is explicitly cleared through this attribute. What: /sys/bus/platform/devices/ACPI000E:00/dc_alarm Date: March 2018 Contact: Rafael J. Wysocki Description: (RW,optional) The DC alarm timer value. This attribute is only present if the TAD supports a separate DC timer. It is analogous to the ac_alarm attribute. What: /sys/bus/platform/devices/ACPI000E:00/dc_policy Date: March 2018 Contact: Rafael J. Wysocki Description: (RW,optional) The DC alarm expired timer wake policy. This attribute is only present if the TAD supports a separate DC timer. It is analogous to the ac_policy attribute. What: /sys/bus/platform/devices/ACPI000E:00/dc_status Date: March 2018 Contact: Rafael J. Wysocki Description: (RW,optional) The DC alarm status. This attribute is only present if the TAD supports a separate DC timer. It is analogous to the ac_status attribute.