+Texas Instruments CPSW switchdev based ethernet driver
+======================================================
+
+:Version: 2.0
+
+Port renaming
+=============
+
+On older udev versions renaming of ethX to swXpY will not be automatically
+supported
+
+In order to rename via udev::
+
+ ip -d link show dev sw0p1 | grep switchid
+
+ SUBSYSTEM=="net", ACTION=="add", ATTR{phys_switch_id}==<switchid>, \
+ ATTR{phys_port_name}!="", NAME="sw0$attr{phys_port_name}"
+
+
+Dual mac mode
+=============
+
+- The new (cpsw_new.c) driver is operating in dual-emac mode by default, thus
+ working as 2 individual network interfaces. Main differences from legacy CPSW
+ driver are:
+
+ - optimized promiscuous mode: The P0_UNI_FLOOD (both ports) is enabled in
+ addition to ALLMULTI (current port) instead of ALE_BYPASS.
+ So, Ports in promiscuous mode will keep possibility of mcast and vlan
+ filtering, which is provides significant benefits when ports are joined
+ to the same bridge, but without enabling "switch" mode, or to different
+ bridges.
+ - learning disabled on ports as it make not too much sense for
+ segregated ports - no forwarding in HW.
+ - enabled basic support for devlink.
+
+ ::
+
+ devlink dev show
+ platform/48484000.switch
+
+ devlink dev param show
+ platform/48484000.switch:
+ name switch_mode type driver-specific
+ values:
+ cmode runtime value false
+ name ale_bypass type driver-specific
+ values:
+ cmode runtime value false
+
+Devlink configuration parameters
+================================
+
+See Documentation/networking/devlink/ti-cpsw-switch.rst
+
+Bridging in dual mac mode
+=========================
+
+The dual_mac mode requires two vids to be reserved for internal purposes,
+which, by default, equal CPSW Port numbers. As result, bridge has to be
+configured in vlan unaware mode or default_pvid has to be adjusted::
+
+ ip link add name br0 type bridge
+ ip link set dev br0 type bridge vlan_filtering 0
+ echo 0 > /sys/class/net/br0/bridge/default_pvid
+ ip link set dev sw0p1 master br0
+ ip link set dev sw0p2 master br0
+
+or::
+
+ ip link add name br0 type bridge
+ ip link set dev br0 type bridge vlan_filtering 0
+ echo 100 > /sys/class/net/br0/bridge/default_pvid
+ ip link set dev br0 type bridge vlan_filtering 1
+ ip link set dev sw0p1 master br0
+ ip link set dev sw0p2 master br0
+
+Enabling "switch"
+=================
+
+The Switch mode can be enabled by configuring devlink driver parameter
+"switch_mode" to 1/true::
+
+ devlink dev param set platform/48484000.switch \
+ name switch_mode value 1 cmode runtime
+
+This can be done regardless of the state of Port's netdev devices - UP/DOWN, but
+Port's netdev devices have to be in UP before joining to the bridge to avoid
+overwriting of bridge configuration as CPSW switch driver copletly reloads its
+configuration when first Port changes its state to UP.
+
+When the both interfaces joined the bridge - CPSW switch driver will enable
+marking packets with offload_fwd_mark flag unless "ale_bypass=0"
+
+All configuration is implemented via switchdev API.
+
+Bridge setup
+============
+
+::
+
+ devlink dev param set platform/48484000.switch \
+ name switch_mode value 1 cmode runtime
+
+ ip link add name br0 type bridge
+ ip link set dev br0 type bridge ageing_time 1000
+ ip link set dev sw0p1 up
+ ip link set dev sw0p2 up
+ ip link set dev sw0p1 master br0
+ ip link set dev sw0p2 master br0
+
+ [*] bridge vlan add dev br0 vid 1 pvid untagged self
+
+ [*] if vlan_filtering=1. where default_pvid=1
+
+ Note. Steps [*] are mandatory.
+
+
+On/off STP
+==========
+
+::
+
+ ip link set dev BRDEV type bridge stp_state 1/0
+
+VLAN configuration
+==================
+
+::
+
+ bridge vlan add dev br0 vid 1 pvid untagged self <---- add cpu port to VLAN 1
+
+Note. This step is mandatory for bridge/default_pvid.
+
+Add extra VLANs
+===============
+
+ 1. untagged::
+
+ bridge vlan add dev sw0p1 vid 100 pvid untagged master
+ bridge vlan add dev sw0p2 vid 100 pvid untagged master
+ bridge vlan add dev br0 vid 100 pvid untagged self <---- Add cpu port to VLAN100
+
+ 2. tagged::
+
+ bridge vlan add dev sw0p1 vid 100 master
+ bridge vlan add dev sw0p2 vid 100 master
+ bridge vlan add dev br0 vid 100 pvid tagged self <---- Add cpu port to VLAN100
+
+FDBs
+----
+
+FDBs are automatically added on the appropriate switch port upon detection
+
+Manually adding FDBs::
+
+ bridge fdb add aa:bb:cc:dd:ee:ff dev sw0p1 master vlan 100
+ bridge fdb add aa:bb:cc:dd:ee:fe dev sw0p2 master <---- Add on all VLANs
+
+MDBs
+----
+
+MDBs are automatically added on the appropriate switch port upon detection
+
+Manually adding MDBs::
+
+ bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent vid 100
+ bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent <---- Add on all VLANs
+
+Multicast flooding
+==================
+CPU port mcast_flooding is always on
+
+Turning flooding on/off on swithch ports:
+bridge link set dev sw0p1 mcast_flood on/off
+
+Access and Trunk port
+=====================
+
+::
+
+ bridge vlan add dev sw0p1 vid 100 pvid untagged master
+ bridge vlan add dev sw0p2 vid 100 master
+
+
+ bridge vlan add dev br0 vid 100 self
+ ip link add link br0 name br0.100 type vlan id 100
+
+Note. Setting PVID on Bridge device itself working only for
+default VLAN (default_pvid).
+
+NFS
+===
+
+The only way for NFS to work is by chrooting to a minimal environment when
+switch configuration that will affect connectivity is needed.
+Assuming you are booting NFS with eth1 interface(the script is hacky and
+it's just there to prove NFS is doable).
+
+setup.sh::
+
+ #!/bin/sh
+ mkdir proc
+ mount -t proc none /proc
+ ifconfig br0 > /dev/null
+ if [ $? -ne 0 ]; then
+ echo "Setting up bridge"
+ ip link add name br0 type bridge
+ ip link set dev br0 type bridge ageing_time 1000
+ ip link set dev br0 type bridge vlan_filtering 1
+
+ ip link set eth1 down
+ ip link set eth1 name sw0p1
+ ip link set dev sw0p1 up
+ ip link set dev sw0p2 up
+ ip link set dev sw0p2 master br0
+ ip link set dev sw0p1 master br0
+ bridge vlan add dev br0 vid 1 pvid untagged self
+ ifconfig sw0p1 0.0.0.0
+ udhchc -i br0
+ fi
+ umount /proc
+
+run_nfs.sh:::
+
+ #!/bin/sh
+ mkdir /tmp/root/bin -p
+ mkdir /tmp/root/lib -p
+
+ cp -r /lib/ /tmp/root/
+ cp -r /bin/ /tmp/root/
+ cp /sbin/ip /tmp/root/bin
+ cp /sbin/bridge /tmp/root/bin
+ cp /sbin/ifconfig /tmp/root/bin
+ cp /sbin/udhcpc /tmp/root/bin
+ cp /path/to/setup.sh /tmp/root/bin
+ chroot /tmp/root/ busybox sh /bin/setup.sh
+