diff options
Diffstat (limited to 'Documentation/hwmon/emc6w201')
-rw-r--r-- | Documentation/hwmon/emc6w201 | 42 |
1 files changed, 0 insertions, 42 deletions
diff --git a/Documentation/hwmon/emc6w201 b/Documentation/hwmon/emc6w201 deleted file mode 100644 index 757629b12897..000000000000 --- a/Documentation/hwmon/emc6w201 +++ /dev/null @@ -1,42 +0,0 @@ -Kernel driver emc6w201 -====================== - -Supported chips: - * SMSC EMC6W201 - Prefix: 'emc6w201' - Addresses scanned: I2C 0x2c, 0x2d, 0x2e - Datasheet: Not public - -Author: Jean Delvare <jdelvare@suse.de> - - -Description ------------ - -From the datasheet: - -"The EMC6W201 is an environmental monitoring device with automatic fan -control capability and enhanced system acoustics for noise suppression. -This ACPI compliant device provides hardware monitoring for up to six -voltages (including its own VCC) and five external thermal sensors, -measures the speed of up to five fans, and controls the speed of -multiple DC fans using three Pulse Width Modulator (PWM) outputs. Note -that it is possible to control more than three fans by connecting two -fans to one PWM output. The EMC6W201 will be available in a 36-pin -QFN package." - -The device is functionally close to the EMC6D100 series, but is -register-incompatible. - -The driver currently only supports the monitoring of the voltages, -temperatures and fan speeds. Limits can be changed. Alarms are not -supported, and neither is fan speed control. - - -Known Systems With EMC6W201 ---------------------------- - -The EMC6W201 is a rare device, only found on a few systems, made in -2005 and 2006. Known systems with this device: -* Dell Precision 670 workstation -* Gigabyte 2CEWH mainboard |