aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/asb100
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/asb100')
-rw-r--r--Documentation/hwmon/asb10072
1 files changed, 0 insertions, 72 deletions
diff --git a/Documentation/hwmon/asb100 b/Documentation/hwmon/asb100
deleted file mode 100644
index ab7365e139be..000000000000
--- a/Documentation/hwmon/asb100
+++ /dev/null
@@ -1,72 +0,0 @@
-Kernel driver asb100
-====================
-
-Supported Chips:
- * Asus ASB100 and ASB100-A "Bach"
- Prefix: 'asb100'
- Addresses scanned: I2C 0x2d
- Datasheet: none released
-
-Author: Mark M. Hoffman <mhoffman@lightlink.com>
-
-Description
------------
-
-This driver implements support for the Asus ASB100 and ASB100-A "Bach".
-These are custom ASICs available only on Asus mainboards. Asus refuses to
-supply a datasheet for these chips. Thanks go to many people who helped
-investigate their hardware, including:
-
-Vitaly V. Bursov
-Alexander van Kaam (author of MBM for Windows)
-Bertrik Sikken
-
-The ASB100 implements seven voltage sensors, three fan rotation speed
-sensors, four temperature sensors, VID lines and alarms. In addition to
-these, the ASB100-A also implements a single PWM controller for fans 2 and
-3 (i.e. one setting controls both.) If you have a plain ASB100, the PWM
-controller will simply not work (or maybe it will for you... it doesn't for
-me).
-
-Temperatures are measured and reported in degrees Celsius.
-
-Fan speeds are reported in RPM (rotations per minute). An alarm is
-triggered if the rotation speed has dropped below a programmable limit.
-
-Voltage sensors (also known as IN sensors) report values in volts.
-
-The VID lines encode the core voltage value: the voltage level your
-processor should work with. This is hardcoded by the mainboard and/or
-processor itself. It is a value in volts.
-
-Alarms: (TODO question marks indicate may or may not work)
-
-0x0001 => in0 (?)
-0x0002 => in1 (?)
-0x0004 => in2
-0x0008 => in3
-0x0010 => temp1 (1)
-0x0020 => temp2
-0x0040 => fan1
-0x0080 => fan2
-0x0100 => in4
-0x0200 => in5 (?) (2)
-0x0400 => in6 (?) (2)
-0x0800 => fan3
-0x1000 => chassis switch
-0x2000 => temp3
-
-Alarm Notes:
-
-(1) This alarm will only trigger if the hysteresis value is 127C.
-I.e. it behaves the same as w83781d.
-
-(2) The min and max registers for these values appear to
-be read-only or otherwise stuck at 0x00.
-
-TODO:
-* Experiment with fan divisors > 8.
-* Experiment with temp. sensor types.
-* Are there really 13 voltage inputs? Probably not...
-* Cleanups, no doubt...
-